58 resultados para Aerodynamic heating
Resumo:
Phosphorothioate diester oligonucleotides proved to be fully compatible with maleimides in the context of two different conjugation reactions: (a) reaction of 5′diene-[phosphorothioate oligonucleotides] with maleimido-containing compounds to afford the Diels-Alder cycloadduct; (b) conjugation of 5′maleimido-[phosphorothioate oligonucleotides] with thiol-containing compounds. No evidence of reaction between phosphorothioate diesters and maleimides was found in any of these processes. Importantly, in the preparation of 5′maleimido-[phosphorothioate oligonucleotides] from [protected maleimido]-[phosphorothioate oligonucleotides], which requires the maleimide to be deprotected by retro-Diels-Alder reaction (heating for 3-4 h in toluene at 90 °C), no addition of phosphorothioate diester to the maleimide was found either. Finally, maleimide-[phosphorothioate monoester] conjugation was also explored for comparison purposes.
Resumo:
Extension of shelf life and preservation of products are both very important for the food industry. However, just as with other processes, speed and higher manufacturing performance are also beneficial. Although microwave heating is utilized in a number of industrial processes, there are many unanswered questions about its effects on foods. Here we analyze whether the effects of microwave heating with continuous flow are equivalent to those of traditional heat transfer methods. In our study, the effects of heating of liquid foods by conventional and continuous flow microwave heating were studied. Among other properties, we compared the stability of the liquid foods between the two heat treatments. Our goal was to determine whether the continuous flow microwave heating and the conventional heating methods have the same effects on the liquid foods, and, therefore, whether microwave heat treatment can effectively replace conventional heat treatments. We have compared the colour, separation phenomena of the samples treated by different methods. For milk, we also monitored the total viable cell count, for orange juice, vitamin C contents in addition to the taste of the product by sensory analysis. The majority of the results indicate that the circulating coil microwave method used here is equivalent to the conventional heating method based on thermal conduction and convection. However, some results in the analysis of the milk samples show clear differences between heat transfer methods. According to our results, the colour parameters (lightness, red-green and blue-yellow values) of the microwave treated samples differed not only from the untreated control, but also from the traditional heat treated samples. The differences are visually undetectable, however, they become evident through analytical measurement with spectrophotometer. This finding suggests that besides thermal effects, microwave-based food treatment can alter product properties in other ways as well.
Resumo:
Contexto Una central nuclear, al igual que cualquier otro tipo de central generadora de energía eléctrica, mediante turbinas de vapor, está basada en un proceso termodinámico. El rendimiento de las mismas es función del salto entálpico del vapor, para mejorarlo las centrales están constituidas por un ciclo compound formado por turbina de alta presión y turbinas de baja presión, y un ciclo regenerativo consistente en calentar el agua de alimentación antes de su introducción a los generadores de vapor. Un ciclo regenerativo está basado en etapas de calentadores o cambiadores de calor para aprovechar al máximo la energía térmica del vapor, este proyecto está basado en la mejora y optimización del proceso de control de estos para contribuir a mejorar el rendimiento de la central. Objetivo Implementar un sistema de control que nos permita modernizar los clásicos sistemas basados en controles locales y comunicaciones analógicas. Mejorar el rendimiento del ciclo regenerativo de la central, aprovechando las mejoras tecnológicas que ofrece el mercado, tanto en el hardware como en el software de los sistemas de instrumentación y control. Optimizar el rendimiento de los lazos de control de cada uno de los elementos del ciclo regenerativo mediante estrategias de control. Procedimiento Desarrollo de un sistema de control actualizado considerando, como premisa principal, la fiabilidad del sistema, el análisis de fallos y la jerarquización del riesgo. Análisis y cálculo de los lazos de control considerando las premisas establecidas. Configuración de los lazos mediante estrategias de control que nos permitan optimizar y minimizar los efectos del fallo. Para ello se han utilizado parámetros y datos extraídos de la Central Nuclear de Ascó. Conclusiones Se ha modernizado y optimizado el sistema de control mejorando el rendimiento del ciclo regenerativo. Se ha conseguido un sistema más fiable, reduciendo el riesgo del fallo y disminuyendo los efectos de los mismos. El coste de un proyecto de estas características es inferior al de un sistema convencional y ofrece más posibilidades. Es un sistema abierto que permite utilizar e interconectar equipos de diferentes fabricantes, lo que favorece tanto el mantenimiento como las posibles ampliaciones futuras del sistema.
Resumo:
The effects of the addition of heated oils to feeds (3%, w/w) and the dietary supplementation with a-tocopheryl acetate (TA; 100 mg/kg) and Zn (200 mg/kg) on rabbit tissue fatty acid (FA) composition and on the Zn, Cu, Fe and Se content in meat were assessed. Heating unrefined sunflower oil (SO) at 558C for 245 h increased its content in primary oxidation products and reduced its a-tocopherol content. However, this did not significantly affect tissue FA composition. Heating SO at 1408C for 31 h increased its content in secondary oxidation products and in some FA isomers asc9,t11-CLA and di-trans CLA. This led to increases in di-trans CLA in liver and in t9,c12-18:2 in meat. The c9,t11-CLA was the most incorporated CLA isomer in tissues. The dietary supplementation with a-TA did not affect the FA composition of plasma, liver or meat. The cooking of vacuum-packed rabbit meat at 788C for 5 min reduced significantly but slightly its polyunsaturated FA content. The dietary supplementation with Zn did not modify the content of Zn, Fe or Se in meat, but it reduced its Cu content. On the other hand, it increased the content of some FAs in meat when SO heated at 1408C for 31 h was added to feeds.
Resumo:
Chiral symmetrical alk-2-yne-1,4-diols have been stereoselectively transformed into 5-alkyl-4-alkenyl-4-phenyl-1,3-oxazolidin- 2-ones, which are precursors of quaternary α-amino β-hydroxy acids. The key step was the cyclization of the bis(tosylcarbamates) of 2- phenylalk-2-yne-1,4-diols, easily obtained from the starting chiral diols. These cyclizations were accomplished with complete regioselectivity and up to 92:8 dr in the presence of catalytic amounts of Ni(0) or Pd (II) derivatives under microwave heating.
Resumo:
Chronic obstructive pulmonary disease (copd) is a major cause of illness and death throughout the world. It affects about 10% of the general population, but its prevalence among heavy smokers can reach 50%.COPD is the fourth leading cause of death in most industrialized countries, and it is projected to be the third leading cause of death worldwide by 2020. Tobacco smoking is the primary risk factor for the development of COPD, but other factors, such as burning biomass fuels for cooking and heating, are important causes of COPD in many developing countries....
Resumo:
Elnostreclientésunpromotoralqualselihaencarregatlaconstrucciód’unallard’infantsprivadaperaunacol•∙legideprimàriaDinselrecintedel’escolaprimàriahihaunespaidestinatperlaconstrucciódelallard’infants,peròlaintencióésquelaLlard’Infantstinguitotalindependènciaenergèticadel’edificiexistent. L’objectedelprojecteéseldissenyidimensionamentd’unainstal•∙laciódecalefacciómitjançantcalderadebiomassa,quesatisfacilesnecessitatsdelaLlard’Infants,ieldissenyidimensionamentd’unsistemasolartèrmicperabastirl’aiguacalentasanitàriaiquecomenergiaderecolzamentutilitzilacalderadebiomassa.Comaaltresrequisitsatenirencomptehihaeldimensionamentd’unaltresistemaalternatiud’estalvid’energiaperreduirelconsumdelainstal•∙lacióifer--‐laaixíméseficientieldesigexprésdelpropietari,quedeserpossible,liagradariainstal•∙larterraradiant.Améstambés’haencarregatl’elaboraciód’unestudideviabilitateconòmica,delainversiód’instal•∙larunacalderadebiomassaenfrontaladeinstal•∙larunsistemaambcalderadegasoilpertenirencompteeltempsderetorneconòmicil’amortització.Perdissenyaridimensionarlainstal•∙laciós’hatingutencompteelcomplimentdelesexigènciesmarcadespelRITE,pelCodiTècnicdel’Edificacióitambés’havolgutadaptarlesinstal•∙lacionsalesDirectivesEuropees2010/31/UEi2012/27/UEenrelacióaeficiènciaenergètica
Resumo:
With the aim of monitoring the dynamics of the Livingston Island ice cap, the Departament de Geodinàmica i Geofísica of the Universitat de Barcelona began ye a r ly surveys in the austral summer of 1994-95 on Johnsons Glacier. During this field campaign 10 shallow ice cores were sampled with a manual ve rtical ice-core drilling machine. The objectives were: i) to detect the tephra layer accumulated on the glacier surface, attributed to the 1970 Deception Island pyroclastic eruption, today interstratified; ii) to verify wheter this layer might serve as a reference level; iii) to measure the 1 3 7Cs radio-isotope concentration accumulated in the 1965 snow stratum; iv) to use the isochrone layer as a mean of verifying the age of the 1970 tephra layer; and, v) to calculate both the equilibrium line of the glacier and average mass balance over the last 28 years (1965-1993). The stratigr a p hy of the cores, their cumulative density curves and the isothermal ice temperatures recorded confi rm that Johnsons Glacier is a temperate glacier. Wi n d, solar radiation heating and liquid water are the main agents controlling the ve rtical and horizontal redistribution of the volcanic and cryoclastic particles that are sedimented and remain interstratified within the g l a c i e r. It is because of this redistribution that the 1970 tephra layer does not always serve as a ve ry good reference level. The position of the equilibrium line altitude (ELA) in 1993, obtained by the 1 3 7Cs spectrometric analysis, varies from about 200 m a.s.l. to 250 m a.s.l. This indicates a rising trend in the equilibrium line altitude from the beginning of the 1970s to the present day. The va rying slope orientation of Johnsons Glacier relative to the prevailing NE wind gives rise to large local differences in snow accumulation, which locally modifies the equilibrium line altitude. In the cores studied, 1 3 7Cs appears to be associated with the 1970 tephra laye r. This indicates an intense ablation episode throughout the sampled area (at least up to 330 m a.s.l), which probably occurred synchronically to the 1970 tephra deposition or later. A rough estimate of the specific mass balance reveals a considerable accumulation gradient related to the increase with altitude.
Resumo:
We investigated convection caused by surface cooling and mixing attributable to wind shear stress and their roles as agents for the transport of phytoplankton cells in the water column by carrying out two daily surveys during the stratified period of the Sau reservoir. Green algae, diatoms, and cryptophyceae were the dominant phytoplankton communities during the surveys carried out in the middle (July) and end (September) of the stratified period. We show that a system with a linear stratification and that is subject to weak surface forcing, with weak winds , < 4 m S (-1) and low energy dissipation rate values of the order of 1028 m2 s23 or lower, enables the formation of thin phytoplankton layers. These layers quickly disappear when water parcels mix because there is a medium external forcing (convection) induced by the night surface cooling, which is characterized by energy dissipation rates on the order of , 5x10(-8)m2s(-3). During both surveys the wind generated internal waves during the entire diurnal cycle. During the day, and because of the weak winds, phytoplankton layers rise in the water column up to a depth determined by both solar heating and internal waves. In contrast, during the night phytoplankton mixes down to a depth determined by both convection and internal waves. These internal waves, together with the wind-driven current generated at the surface, seem to be the agents responsible for the horizontal transport of phytoplankton across the reservoir.
Resumo:
Previous results concerning radiative emission under laser irradiation of silicon nanopowder are reinterpreted in terms of thermal emission. A model is developed that considers the particles in the powder as independent, so under vacuum the only dissipation mechanism is thermal radiation. The supralinear dependence observed between the intensity of the emitted radiation and laser power is predicted by the model, as is the exponential quenching when the gas pressure around the sample increases. The analysis allows us to determine the sample temperature. The local heating of the sample has been assessed independently by the position of the transverse optical Raman mode. Finally, it is suggested that the photoluminescence observed in porous silicon and similar materials could, in some cases, be blackbody radiation
Resumo:
Moltes vegades l’usuari d’una instal•lació de climatització o calefacció, no dóna la suficient importància al sistema que l’hi ha de proporcionar un millor confort amb el màxim rendiment. Aquest confort és un factor determinant, entre molts d’altres, de la “qualitat de vida”. Mentre que el rendiment és un factor important a nivell econòmic i ecològic. Tot i tenir prevalença els aspectes d’estalvi energètic, aquests no impliquen haver de renunciar a un confort tèrmic i a un estalvi econòmic. Un dels aspectes que es centra el projecte és promoure l’ús racional de les fonts energètiques (solar, biomassa) per a la correcta climatització dels habitatges. El projecte es desenvolupa en l’àmbit domèstic, concretament correspon a un habitatge unifamiliar. Aquest està situat a la població de Roda de Ter, província de Barcelona. L’objectiu principal del projecte és l’elecció del sistema de climatització i el seu dimensionament, per tal de donar el màxim confort als usuaris que habitin a la vivenda. Criteris ambientals i eficients han estat objecte a considerar pel disseny constructiu de l’habitatge. Una de les mesures importants presses en el projecte, ha estat l’elecció de les diferents parts que formen la instal•lació de climatització. Es fa referència als aïllaments dels tancaments, el sistema solar de recolzament, equips de producció de fred i calor, entre d’altres. En el projecte, s’ha dut a terme un estudi dels diferents tancaments de l’habitatge, tot determinat per a cada un d’ells, el seu coeficient de transmissió tèrmica. Per seleccionar l’equipament més adequat s’ha partit de les condicions climatològiques del municipi de Roda de Ter i s’ha realitzat el càlcul de les necessitats tèrmiques de l’edifici. L’habitatge incorpora una instal•lació de captació solar tèrmica. Aquesta aportarà un suport energètic a tot el sistema de producció de calor, ja sigui per la producció d’aigua calenta sanitària com per el calefactat de la vivenda. La col•locació dels panells a la façana sud tindrà una doble funció: a més de proporcionar energia solar tèrmica, serviran d’elements de protecció solar en la temporada d’estiu. La caldera usada per donar recolzament tèrmic utilitzarà com a combustible el “pellet”. El “pellet” és un tipus de biomassa llenyosa que consta d’un derivat de la fusta en format granulat. Es defineix i es detalla el consum energètic en biomassa, electricitat i cost econòmic anual que ocasionarà la instal.lació dissenyada. El sistema de terra radiant adoptat permetrà el refrescament en èpoques estivals i el calefactat en èpoques hivernals. Aquest donarà el confort tèrmic necessari a cada estança de l’habitatge. En el projecte també es marquen les pautes bàsiques pel control de la instal•lació solar així com el control dels grups de bombament i la mescla d’aigua del terra radiant.
Resumo:
El Hospital Punta de Europa en Algeciras (Cádiz), centro sanitario del Servicio Andaluz de Salud, desea optimizar la gestión de sus instalaciones de generación de energía térmica (vapor, agua caliente sanitaria y agua caliente de calefacción) y adecuarlas a la normativa vigente así como la sustitución de bajantes del edificio, para lo cual sacará a concurso público la licitación para la concesión de dominio público de dichas instalaciones. Para definir el alcance y condiciones de la citada concesión, el Hospital Punta de Europa (Algeciras) del Servicio Andaluz de Salud ha solicitado a Pedro Alonso Martín el estudio para la reforma y adecuación de las instalaciones productoras de energía térmica del citado Hospital. El objetivo principal de este trabajo es hacer un estudio, propuesta y valoración de las actuaciones necesarias para la reforma y mejora de la explotación de las instalaciones generadoras de energía térmica y de la red saneamiento interior del Hospital Punta de Europa de Algeciras (Cádiz). Las actuales instalaciones de generación térmica consumidoras de energía del hospital dentro del alcance de este Proyecto son: Generación de vapor (lavandería y esterilización). Producción de agua caliente sanitaria (ACS). Producción de agua caliente de calefacción. La mayoría de los equipos productores de energía datan del año 1975, por lo que en la mayoría de los casos se ha cumplido su plazo de amortización y periodo de vida útil. Se hace necesaria la instalación de gas natural, debido a que se tendrá que abastecer a todas las calderas de la central térmica. El diseño del sistema de producción de agua caliente sanitaria garantiza el máximo confort y economía del usuario, compatible con el máximo ahorro energético y la protección del medio ambiente, cubriendo las necesidades de agua caliente sanitaria mediante la combinación de un sistema de calderas a gas con los colectores solares.
Resumo:
RESUMEN La energia eolica se considera una forma indirecta de energia solar. Entre el 1 y 2% de la energia proveniente del sol se convierte en viento, debido al movimiento del aire ocasionado por el desigual calentamiento de la superficie terrestre. La energia cinetica del viento puede transformarse en energia util, tanto mecanica como electrica. La energia eolica, transformada en energia mecanica ha sido historicamente aprovechada, pero su uso para la generacion de energia electrica es mas reciente, en respuesta a la crisis del petroleo y a los impactos ambientales derivados del uso de combustibles. El objetivo principal de este trabajo es hacer un analisis de viabilidad desde un punto de vista tecnico y economico de un parque eolico situado en el municipio de Barasoain (Navarra). Desde el punto de vista tecnico se han estudiado los aspectos constructivos del parque considerando sus diferentes infraestructuras de obra civil y electrica asi como los niveles de recurso eolico. En el ambito economico y financiero se han analizado los aspectos y ratios mas relevantes que definen un proyecto de estas caracteristicas asi como el modelo de financiacion elegida basada en el Project- Finance. Entre las conclusiones mas destacadas de este proyecto cabe destacar la contribucion de la construccion del parque al desarrollo social y economico de la zona donde queda ubicado contribuyendo a la creacion de puestos de trabajo, tanto en la fase de construccion como de explotacion y una perfecta armonia con condicionantes medioambientales de la zona. El analisis tecnico realizado nos indica la viabilidad tecnica del parque tanto desde el punto de vista de recurso eolico como la idoneidad para poder evacuar la energia producida. Por otro lado, los resultados obtenidos cumplen perfectamente con los estandares requeridos por los financiadores de los parques y resultando ser muy atractivos para sus accionistas