71 resultados para variable sampling interval
Resumo:
The experiential sampling method (ESM) was used to collect data from 74 parttimestudents who described and assessed the risks involved in their current activitieswhen interrupted at random moments by text messages. The major categories ofperceived risk were short-term in nature and involved loss of time or materials relatedto work and physical damage (e.g., from transportation). Using techniques of multilevelanalysis, we demonstrate effects of gender, emotional state, and types of risk onassessments of risk. Specifically, females do not differ from males in assessing thepotential severity of risks but they see these as more likely to occur. Also, participantsassessed risks to be lower when in more positive self-reported emotional states. Wefurther demonstrate the potential of ESM by showing that risk assessments associatedwith current actions exceed those made retrospectively. We conclude by notingadvantages and disadvantages of ESM for collecting data about risk perceptions.
Resumo:
The approximants to regular continued fractions constitute `best approximations' to the numbers they converge to in two ways known as of the first and the second kind.This property of continued fractions provides a solution to Gosper's problem of the batting average: if the batting average of a baseball player is 0.334, what is the minimum number of times he has been at bat? In this paper, we tackle somehow the inverse question: given a rational number P/Q, what is the set of all numbers for which P/Q is a `best approximation' of one or the other kind? We prove that inboth cases these `Optimality Sets' are intervals and we give aprecise description of their endpoints.
Resumo:
We present I-band deep CCD exposures of the fields of galactic plane radio variables. An optical counterpart, based on positional coincidence, has been found for 15 of the 27 observed program objects. The Johnson I magnitude of the sources identified is in the range 18-21.
Resumo:
A considerable fraction of the -ray sources discovered with the Energetic Gamma-Ray Experiment Telescope (EGRET) remain unidentified. The EGRET sources that have been properly identified are either pulsars or variable sources at both radio and gamma-ray wavelengths. Most of the variable sources are strong radio blazars. However, some low galactic-latitude EGRET sources, with highly variable -ray emission, lack any evident counterpart according to the radio data available until now. Aims. The primary goal of this paper is to identify and characterise the potential radio counterparts of four highly variable -ray sources in the galactic plane through mapping the radio surroundings of the EGRET confidence contours and determining the variable radio sources in the field whenever possible. Methods. We have carried out a radio exploration of the fields of the selected EGRET sources using the Giant Metrewave Radio Telescope (GMRT) interferometer at 21 cm wavelength, with pointings being separated by months. Results. We detected a total of 151 radio sources. Among them, we identified a few radio sources whose flux density has apparently changed on timescales of months. Despite the limitations of our search, their possible variability makes these objects a top-priority target for multiwavelength studies of the potential counterparts of highly variable, unidentified gamma-ray sources.
Resumo:
This paper describes the development and applications of a super-resolution method, known as Super-Resolution Variable-Pixel Linear Reconstruction. The algorithm works combining different lower resolution images in order to obtain, as a result, a higher resolution image. We show that it can make significant spatial resolution improvements to satellite images of the Earth¿s surface allowing recognition of objects with size approaching the limiting spatial resolution of the lower resolution images. The algorithm is based on the Variable-Pixel Linear Reconstruction algorithm developed by Fruchter and Hook, a well-known method in astronomy but never used for Earth remote sensing purposes. The algorithm preserves photometry, can weight input images according to the statistical significance of each pixel, and removes the effect of geometric distortion on both image shape and photometry. In this paper, we describe its development for remote sensing purposes, show the usefulness of the algorithm working with images as different to the astronomical images as the remote sensing ones, and show applications to: 1) a set of simulated multispectral images obtained from a real Quickbird image; and 2) a set of multispectral real Landsat Enhanced Thematic Mapper Plus (ETM+) images. These examples show that the algorithm provides a substantial improvement in limiting spatial resolution for both simulated and real data sets without significantly altering the multispectral content of the input low-resolution images, without amplifying the noise, and with very few artifacts.
Resumo:
Microquasars are binary star systems with relativistic radio-emitting jets. They are potential sources of cosmic rays and can be used to elucidate the physics of relativistic jets. We report the detection of variable gamma-ray emission above 100 gigaelectron volts from the microquasar LS I 61 + 303. Six orbital cycles were recorded. Several detections occur at a similar orbital phase, which suggests that the emission is periodic. The strongest gamma-ray emission is not observed when the two stars are closest to one another, implying a strong orbital modulation of the emission or absorption processes.
Resumo:
Document en què es proposen una sèrie d'activitats pràctiques ordenades i agrupades en sessions, per tal de treballar la creativitat i la improvisació musical amb els alumnes de secundària.
Resumo:
AMADEUS is a dexterous subsea robot hand incorporating force and slip contact sensing, using fluid filled tentacles for fingers. Hydraulic pressure variations in each of three flexible tubes (bellows) in each finger create a bending moment, and consequent motion or increase in contact force during grasping. Such fingers have inherent passive compliance, no moving parts, and are naturally depth pressure-compensated, making them ideal for reliable use in the deep ocean. In addition to the mechanical design, development of the hand has also considered closed loop finger position and force control, coordinated finger motion for grasping, force and slip sensor development/signal processing, and reactive world modeling/planning for supervisory `blind grasping¿. Initially, the application focus is for marine science tasks, but broader roles in offshore oil and gas, salvage, and military use are foreseen. Phase I of the project is complete, with the construction of a first prototype. Phase I1 is now underway, to deploy the hand from an underwater robot arm, and carry out wet trials with users.
Resumo:
AMADEUS is a dexterous subsea robot hand incorporating force and slip contact sensing, using fluid filled tentacles for fingers. Hydraulic pressure variations in each of three flexible tubes (bellows) in each finger create a bending moment, and consequent motion or increase in contact force during grasping. Such fingers have inherent passive compliance, no moving parts, and are naturally depth pressure-compensated, making them ideal for reliable use in the deep ocean. In addition to the mechanical design, development of the hand has also considered closed loop finger position and force control, coordinated finger motion for grasping, force and slip sensor development/signal processing, and reactive world modeling/planning for supervisory `blind grasping¿. Initially, the application focus is for marine science tasks, but broader roles in offshore oil and gas, salvage, and military use are foreseen. Phase I of the project is complete, with the construction of a first prototype. Phase I1 is now underway, to deploy the hand from an underwater robot arm, and carry out wet trials with users.
Resumo:
A simple, low-cost accessory (patent pending) with only two flat mirrors and a new variable-angle mechanism has been developed for infrared specular reflectance measurements. The system allows the angles of incidence to be varied continuously from 15° (near normal incidence) to 85° (near grazing angle) without losing the alignment of the accessory. The reflectivity of boron nitride thin films deposited on metallic substrates has been measured at different angles of incidence to demonstrate the utility of this accessory.
Resumo:
All derivations of the one-dimensional telegraphers equation, based on the persistent random walk model, assume a constant speed of signal propagation. We generalize here the model to allow for a variable propagation speed and study several limiting cases in detail. We also show the connections of this model with anomalous diffusion behavior and with inertial dichotomous processes.
Resumo:
A modified magnesium hydrogen breath test, using end expiratory breath sampling, is described to investigate achlorhydria. The efficacy of this test in the diagnostic investigation of pernicious anaemia was compared with that of serum pepsinogen I. Twenty one patients with pernicious anaemia--that is, patients with achlorhydria--and 22 with healed duodenal ulcer and normal chlorhydria were studied. Magnesium hydrogen breath test, serum pepsinogen I, serum gastrin, and standard gastric acid secretory tests were performed in all subjects. The mean (SEM) hydrogen peak value was lower in patients with pernicious anaemia than in the duodenal ulcer group (21.7 (1.9) v 71.3 (5.2) ppm; p = 0.00005). The hydrogen peak value had a 95.2% sensitivity and a 100% specificity to detect pentagastrin resistant achlorhydria. Mean serum pepsinogen I concentrations were also significantly lower in patients with pernicious anaemia than in the duodenal ulcer group (10.7 (2.7) v 123.6 (11.8) micrograms/l p = 0.00005). Sensitivity and specificity to detect pernicious anaemia were both 100% for pepsinogen I. It is concluded that this modified magnesium hydrogen breath test is a simple, noninvasive, cost effective, and accurate method to assess achlorhydria and may be useful in the diagnostic investigation of patients with suspected pernicious anaemia.
Resumo:
Abstract. The ability of 2 Rapid Bioassessment Protocols (RBPs) to assess stream water quality was compared in 2 Mediterranean-climate regions. The most commonly used RBPs in South Africa (SAprotocol) and the Iberian Peninsula (IB-protocol) are both multihabitat, field-based methods that use macroinvertebrates. Both methods use preassigned sensitivity weightings to calculate metrics and biotic indices. The SA- and IB-protocols differ with respect to sampling equipment (mesh size: 1000 lm vs 250 300 lm, respectively), segregation of habitats (substrate vs flow-type), and sampling and sorting procedures (variable time and intensity). Sampling was undertaken at 6 sites in South Africa and 5 sites in the Iberian Peninsula. Forty-four and 51 macroinvertebrate families were recorded in South Africa and the Iberian Peninsula, respectively; 77.3% of South African families and 74.5% of Iberian Peninsula families were found using both protocols. Estimates of community similarity compared between the 2 protocols were .60% similar among sites in South Africa and .54% similar among sites in the Iberian Peninsula (BrayCurtis similarity), and no significant differences were found between protocols (Multiresponse Permutation Procedure). Ordination based on Non-metric Multidimensional Scaling grouped macroinvertebrate samples on the basis of site rather than protocol. Biotic indices generated with the 2 protocols at each site did not differ. Thus, both RBPs produced equivalent results, and both were able to distinguish between biotic communities (mountain streams vs foothills) and detect water-quality impairment, regardless of differences in sampling equipment, segregation of habitats, and sampling and sorting procedures. Our results indicate that sampling a single habitat may be sufficient for assessing water quality, but a multihabitat approach to sampling is recommended where intrinsic variability of macroinvertebrate assemblages is high (e.g., in undisturbed sites in regions with Mediterranean climates). The RBP of choice should depend on whether the objective is routine biomonitoring of water quality or autecological or faunistic studies.