38 resultados para customer interface


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Nursing terminologies are designed to support nursing practice but, as with any other clinical tool, they should be evaluated. Cross-mapping is a formal method for examining the validity of the existing controlled vocabularies. Objectives: The study aims to assess the inclusiveness and expressiveness of the nursing diagnosis axis of a newly implemented interface terminology by cross-mapping with the NANDA-I taxonomy. Design/Methods: The study applied a descriptive design, using a cross-sectional, bidirectional mapping strategy. The sample included 728 concepts from both vocabularies. Concept cross-mapping was carried out to identify one-to-one, negative, and hierarchical connections. The analysis was conducted using descriptive statistics. Results: Agreement of the raters" mapping achieved 97%. More than 60% of the nursing diagnosis concepts in the NANDA-I taxonomy were mapped to concepts in the diagnosis axis of the new interface terminology; 71.1% were reversely mapped. Conclusions: Main results for outcome measures suggest that the diagnosis axis of this interface terminology meets the validity criterion of cross-mapping when mapped from and to the NANDA-I taxonomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CoCo is a collaborative web interface for the compilation of linguistic resources. In this demo we are presenting one of its possible applications: paraphrase acquisition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interface of MgO/Ag(001) has been studied with density functional theory applied to slabs. We have found that regular MgO films show a small adhesion to the silver substrate, the binding can be increased in off-stoichiometric regimes, either by the presence of O vacancies at the oxide film or by a small excess of O atoms at the interface between the ceramic to the metal. By means of theoretical methods, the scanning tunneling microscopy signatures of these films is also analyzed in some detail. For defect free deposits containing 1 or 2 ML and at low voltages, tunnelling takes place from the surface Ag substrate, and at large positive voltages Mg atoms are imaged. If defects, oxygen vacancies, are present on the surface of the oxide they introduce much easier channels for tunnelling resulting in big protrusions and controlling the shape of the image, the extra O stored at the interface can also be detected for very thin films.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a fully-digital interface circuit for the measurement of inductive sensors using a low-cost microcontroller (µC) and without any intermediate active circuit. Apart from the µC and the sensor, the circuit just requires an external resistor and a reference inductance so that two RL circuits with a high-pass filter (HPF) topology are formed. The µC appropriately excites such RL circuits in order to measure the discharging time of the voltage across each inductance (i.e. sensing and reference) and then it uses such discharging times to estimate the sensor inductance. Experimental tests using a commercial µC show a non-linearity error (NLE) lower than 0.5%FSS (Full-Scale Span) when measuring inductances from 1 mH to 10 mH, and from 10 mH to 100 mH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FEMA's mission is to support our citizens and first responders to ensure that as a Nation we work together to build, sustain, and improve our capability to prepare for, protect against, respond to, recover from, and mitigate all hazards.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A brain-computer interface (BCI) is a new communication channel between the human brain and a computer. Applications of BCI systems comprise the restoration of movements, communication and environmental control. In this study experiments were made that used the BCI system to control or to navigate in virtual environments (VE) just by thoughts. BCI experiments for navigation in VR were conducted so far with synchronous BCI and asynchronous BCI systems. The synchronous BCI analyzes the EEG patterns in a predefined time window and has 2 to 3 degrees of freedom.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thermodynamically consistent damage model for the simulation of progressive delamination under variable mode ratio is presented. The model is formulated in the context of the Damage Mechanics. The constitutive equation that results from the definition of the free energy as a function of a damage variable is used to model the initiation and propagation of delamination. A new delamination initiation criterion is developed to assure that the formulation can account for changes in the loading mode in a thermodynamically consistent way. The formulation proposed accounts for crack closure effets avoiding interfacial penetration of two adjacent layers aftercomplete decohesion. The model is implemented in a finite element formulation. The numerical predictions given by the model are compared with experimental results