36 resultados para Tannery wastewater


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Clogging, measured through head loss across filters, and the filtration quality of different filters using different effluents were studied. The filters used were: 115, 130, and 200 m disc filters; 98, 115, 130, and 178 m screen filters; and a sand filter filled with a single layer of sand with an effective diameter of 0.65 mm. The filters were used with a meat industry effluent and secondary and tertiary effluents of two wastewater treatment plants. It was observed that clogging depended on the type of effluent. With the meat industry effluent, the poorest quality effluent, disc filters clogged more than the other filter types. When the wastewater treatment plant effluents were used, the disc filters showed less frequent clogging. Several physical and chemical parameters, such as total suspended solids, chemical oxygen demand, turbidity, electrical conductivity, pH, and number of particles, were analyzed in the effluents at the entry and exit points of the filters. In general, filters did not reduce the values of the main clogging parameters to a great degree. It was found that the parameter that explained the clogging, expressed as Boucher’s filterability index, was different depending on the type of effluent and filter. The best quality of filtration was achieved with a sand filter when the meat industry effluent was used. No significant differences were observed between the quality of filtration of disc and screen filters when operating with the secondary and tertiary effluents

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Flushing is an important maintenance task that removes accumulated particles in microirrigation laterals that can help to reduce clogging problems. The effect of three dripline flushing frequency treatments (no flushing, one flushing at the end of each irrigation period, and a monthly flushing during the irrigation period) was studied in surface and subsurface drip irrigation systems that operated using a wastewater treatment plant effluent for three irrigation periods of 540 h each. The irrigation systems had two different emitters, one pressure compensating and the other not, both molded and welded onto the interior dripline wall, placed in laterals 87 meters long. Dripline flow of the pressure compensating emitter increased 8% over time, while in the nonpressure compensating emitter, dripline flow increased 25% in the surface driplines and decreased 3% in the subsurface driplines by the emitter clogging. Emitter clogging was affected primarily by the interactions between emitter location, emitter type, and flushing frequency treatment. The number of completely clogged emitters was affected by the interaction between irrigation system and emitter type. There was an average of 3.7% less totally clogged emitters in flushed surface driplines with the pressurecompensating emitter as compared to flushed subsurface laterals with the nonpressure compensating emitter

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this paper was to show the potential additional insight that result from adding greenhouse gas (GHG) emissions to plant performance evaluation criteria, such as effluent quality (EQI) and operational cost (OCI) indices, when evaluating (plant-wide) control/operational strategies in wastewater treatment plants (WWTPs). The proposed GHG evaluation is based on a set of comprehensive dynamic models that estimate the most significant potential on-site and off-site sources of CO2, CH4 and N2O. The study calculates and discusses the changes in EQI, OCI and the emission of GHGs as a consequence of varying the following four process variables: (i) the set point of aeration control in the activated sludge section; (ii) the removal efficiency of total suspended solids (TSS) in the primary clarifier; (iii) the temperature in the anaerobic digester; and (iv) the control of the flow of anaerobic digester supernatants coming from sludge treatment. Based upon the assumptions built into the model structures, simulation results highlight the potential undesirable effects of increased GHG production when carrying out local energy optimization of the aeration system in the activated sludge section and energy recovery from the AD. Although off-site CO2 emissions may decrease, the effect is counterbalanced by increased N2O emissions, especially since N2O has a 300-fold stronger greenhouse effect than CO2. The reported results emphasize the importance and usefulness of using multiple evaluation criteria to compare and evaluate (plant-wide) control strategies in a WWTP for more informed operational decision making

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Today, environmental impact associated with pollution treatment is a matter of great concern. A method is proposed for evaluating environmental risk associated with Advanced Oxidation Processes (AOPs) applied to wastewater treatment. The method is based on the type of pollution (wastewater, solids, air or soil) and on materials and energy consumption. An Environmental Risk Index (E), constructed from numerical criteria provided, is presented for environmental comparison of processes and/or operations. The Operation Environmental Risk Index (EOi) for each of the unit operations involved in the process and the Aspects Environmental Risk Index (EAj) for process conditions were also estimated. Relative indexes were calculated to evaluate the risk of each operation (E/NOP) or aspect (E/NAS) involved in the process, and the percentage of the maximum achievable for each operation and aspect was found. A practical application of the method is presented for two AOPs: photo-Fenton and heterogeneous photocatalysis with suspended TiO2 in Solarbox. The results report the environmental risks associated with each process, so that AOPs tested and the operations involved with them can be compared.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El tractament de les aigües en nuclis menors de 2000 habitants es troba pendent de completar per part de l’Agència Catalana de l’Aigua més concretament al corresponent Pla de Sanejament d’Aigües Residuals Urbanes (PSARU). El nucli de La Nou de Gaià (al Tarragonès) es troba pendent de la construcció de la corresponent instal·lació de sanejament, projectada al 2007. Alternativament a les depuradores tradicionals basades en l’ús de formigó (o materials alternatius) i en la despesa elèctrica per assegurar una aeració i una evacuació dels fangs generats, existeixen tecnologies “toves”. Aquestes tecnologies, també conegudes com a “verdes”, es basen en imitar els sistemes naturals maximitzant el seu potencial d’autodepuració. A grans trets existeixen dos formes de depurar les aigües de forma ecològica”: llacunatges (existeix una capa d’aigua lliure) i filtres verds. El present estudi es basa en l’aplicació de filtres verds de morfologia vertical i flux subsuperficial, plantat amb canyes dels generes Scirpus o Phragmites. El resultat han estat 4 bases de 35*35 per a tractar un cabal de 150 m3/d i una població equivalent de 1272.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monitoring of the 'ecological water quality' in 'Aiguamolls de l’Empordà' Natural Park was carried out between September 1996 and August 1997 . The aim of this sampling programme was to design a simple method for rapid detect changes in water quality due to human activity. These include flow regulation by the Park management, nutrient entries from effluents of a nearby wastewater treatment plant or agricultural fertilising. The proposed method is based on the analysis of the abundance of characteristic taxonomic groups of aquatic invertebrates (heleoplankton). The simplicity of the method is ensured by the use of large taxa which are easier to recognise than species. The functioning of aquatic systems has been modelled by means of correspondence analysis between samples and taxa. Results can be summerized in five environmental conditions with a regular community structure. Dominated by one taxon: cladocerans, ostracods, calanoids, cyclopoids and harpacticoids. The dynamics of both freshwater and brackish lagoons can be modelled as displacements between these five groups of environmental conditions. Nevertheless, the “calanoids situation” and the “harpacticoids situation” occur mainly in brackish lagoons, whereas the “cladocerans situation” occurs mainly in freshwater. The four principal axes of data variation have been respectively identified as nutrient turnover rate, hypertrophy, degree of mineralization of the organic matter and eutrophy. The use of these taxa has been validated by comparison with a model obtained from the species. We conclude that in a highly fluctuating system such as the one here, only persistent situations of eutrophy or hypertrophy must be equated to low 'ecological water quality'