75 resultados para Simple bone cyst


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To analyse whether bone mineral density (BMD) assessment is required in postmenopausal women presenting with low trauma vertebral fracture. Methods: Women with vertebral fracture diagnosed over a 10 year period were recruited from our database. The following were excluded: (a) patients with high energy trauma; (b) patients with malignancies; (c) patients with a metabolic bone disease other than osteoporosis. All postmenopausal women were included in whom BMD had been evaluated at both the lumbar spine and femoral neck by dual energy x ray absorptiometry during the six months after the diagnosis. Patients with a potential cause of osteoporosis other than age and menopause were not considered. A total of 215 patients were identified. Results: The mean (SD) age of the patients was 65.9 (6.9) years. BMD at the lumbar spine was 0.725 (0.128) g/cm2 and the T score was ¿2.94 (1.22); BMD at the femoral neck was 0.598 (0.095) g/cm2 and the T score was ¿2.22 (0.89). The BMD of the patients was significantly lower than that of the general population at both the lumbar spine and femoral neck. When the lowest value of the two analysed zones was considered, six patients (3%) showed a normal BMD, 51 (23.5%) osteopenia, and 158 (73.5%) osteoporosis. The prevalence of osteoporosis at the femoral neck increased with age; it was 25% in patients under 60, 35% in patients aged 60¿70, and 60% in patients over 70. Conclusion: These results indicate that bone densitometry is not required in postmenopausal women with clinically diagnosed vertebral fractures if it is performed only to confirm the existence of a low BMD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Criteria to decide which patients with rheumatoid arthritis (RA) should be examined by dual energy x ray absorptiometry (DXA) are currently not available. The rheumatologists from Amsterdam have proposed preliminary criteria based on clinical risk factors (age, disease activity, and functional status). These criteria are preliminary and not widely accepted but might be helpful in practice. The value of the proposal in a group of Spanish postmenopausal women with RA is analysed. METHODS DXA (lumbar spine and femoral neck) was performed in 128 patients recruited from a clinical setting, and the proposed criteria were applied. T and Z scores were established for a Spanish reference population. RESULTS The mean (SD) age of the patients was 61.3 (10.7) and mean duration of the postmenopausal period 14.5 (10.1) years. Mean duration of RA was 13.7 (7.7) years. Mean C reactive protein was 22 (21) mg/l; mean erythrocyte sedimentation rate 26 (18) mm/1st h; and mean Health Assessment Questionnaire score 1.25 (0.79). Ninety (70%) patients fulfilled the proposed criteria. Their sensitivity for the diagnosis of osteoporosis (T score ¿¿2.5 SD) was 86% and their specificity, 43%. Positive predictive value was 54% and negative predictive value, 79%. CONCLUSIONS The proposed criteria seem a good screening method for the selection of those patients with RA whose bone mineral density should be assessed as the sensitivity and negative predictive value are acceptable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparative study of the parts played by technetium-99m diphosphonate and gallium-67 citrate bone scanning in the early diagnosis of infectious spondylodiscitis is presented. Nineteen patients were included in the study. All patients (11 men aged 19-70 years and eight women aged 18-72 years) had a history of back pain varying in duration from one to 15 weeks. A 99mTc diphosphonate bone scan was positive in 17 patients. The two patients with negative results had less than two weeks of back pain. The 67Ga citrate bone scan showed uptake in all patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the design and validation of simple magnetic tweezers for oscillating ferromagnetic beads in the piconewton and nanometer scales. The system is based on a single pair of coaxial coils operating in two sequential modes: permanent magnetization of the beads through a large and brief pulse of magnetic field and generation of magnetic gradients to produce uniaxial oscillatory forces. By using this two step method, the magnetic moment of the beads remains constant during measurements. Therefore, the applied force can be computed and varies linearly with the driving signal. No feedback control is required to produce well defined force oscillations over a wide bandwidth. The design of the coils was optimized to obtain high magnetic fields (280 mT) and gradients (2 T/m) with high homogeneity (5% variation) within the sample. The magnetic tweezers were implemented in an inverted optical microscope with a videomicroscopy-based multiparticle tracking system. The apparatus was validated with 4.5 ¿m magnetite beads obtaining forces up to ~2 pN and subnanometer resolution. The applicability of the device includes microrheology of biopolymer and cell cytoplasm, molecular mechanics, and mechanotransduction in living cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exercicis pràctics de ritme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The average multipole surface-plasmon energy for simple metals, as well as that of ordinary surface and bulk plasmons, is obtained using energy-weighted moments of the electronic response to sufficiently general external perturbations. A local approximation of exchange and correlation effects is used within a jellium model. Band-structure effects are incorporated through an effective electronic mass. Taking advantage of the transparency of the method, we analyze under what circumstances such modes might be observable. It is shown that due to an interplay between Coulomb and kinetic energies, the multipole modes become unobservable for increasing values of the transferred momentum (q) parallel to the surface. The value of q at which the multipole mode becomes unobservable is much smaller than the cutoff value for Landau damping. The effect of the electronic surface diffuseness is also analyzed. We compare our results with previous density-functional calculations and with recent experimental data for Na, K, and Cs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A screened Rutherford cross section is modified by means of a correction factor to obtain the proper transport cross section computed by partial¿wave analysis. The correction factor is tabulated for electron energies in the range 0¿100 keV and for elements in the range from Z=4 to 82. The modified screened Rutherford cross section is shown to be useful as an approximation for the simulation of plural and multiple scattering. Its performance and limitations are exemplified for electrons scattered in Al and Au.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A screened Rutherford cross section is modified by means of a correction factor to obtain the proper transport cross section computed by partial¿wave analysis. The correction factor is tabulated for electron energies in the range 0¿100 keV and for elements in the range from Z=4 to 82. The modified screened Rutherford cross section is shown to be useful as an approximation for the simulation of plural and multiple scattering. Its performance and limitations are exemplified for electrons scattered in Al and Au.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, low-cost accessory (patent pending) with only two flat mirrors and a new variable-angle mechanism has been developed for infrared specular reflectance measurements. The system allows the angles of incidence to be varied continuously from 15° (near normal incidence) to 85° (near grazing angle) without losing the alignment of the accessory. The reflectivity of boron nitride thin films deposited on metallic substrates has been measured at different angles of incidence to demonstrate the utility of this accessory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Collective dynamic properties in Lennard-Jones crystals are investigated by molecular dynamics simulation. The study is focused on properties such as the dynamic structure factors, the longitudinal and transverse currents and the density of states. The influence on these properties of the structural disorder is analyzed by comparing the results for one-component crystals with those for liquids and supercooled liquids at analogous conditions. The effects of species-disorder on the collective properties of binary crystals are also discussed.