46 resultados para Nickel-selective sensor
Resumo:
Wireless Sensor Networks (WSN) are formed by nodes with limited computational and power resources. WSNs are finding an increasing number of applications, both civilian and military, most of which require security for the sensed data being collected by the base station from remote sensor nodes. In addition, when many sensor nodes transmit to the base station, the implosion problem arises. Providing security measures and implosion-resistance in a resource-limited environment is a real challenge. This article reviews the aggregation strategies proposed in the literature to handle the bandwidth and security problems related to many-to-one transmission in WSNs. Recent contributions to secure lossless many-to-one communication developed by the authors in the context of several Spanish-funded projects are surveyed. Ongoing work on the secure lossy many-to-one communication is also sketched.
Resumo:
In this paper, the sensor of an optical mouse is presented as a counterfeit coin detector applied to the two-Euro case. The detection process is based on the short distance image acquisition capabilities of the optical mouse sensor where partial images of the coin under analysis are compared with some partial reference coin images for matching. Results show that, using only the vision sense, the counterfeit acceptance and rejection rates are very similar to those of a trained user and better than those of an untrained user.
Resumo:
Electronic canopy characterization is an important issue in tree crop management. Ultrasonic and optical sensors are the most used for this purpose. The objective of this work was to assess the performance of an ultrasonic sensor under laboratory and field conditions in order to provide reliable estimations of distance measurements to apple tree canopies. To this purpose, a methodology has been designed to analyze sensor performance in relation to foliage ranging and to interferences with adjacent sensors when working simultaneously. Results show that the average error in distance measurement using the ultrasonic sensor in laboratory conditions is ±0.53 cm. However, the increase of variability in field conditions reduces the accuracy of this kind of sensors when estimating distances to canopies. The average error in such situations is ±5.11 cm. When analyzing interferences of adjacent sensors 30 cm apart, the average error is ±17.46 cm. When sensors are separated 60 cm, the average error is ±9.29 cm. The ultrasonic sensor tested has been proven to be suitable to estimate distances to the canopy in field conditions when sensors are 60 cm apart or more and could, therefore, be used in a system to estimate structural canopy parameters in precision horticulture.
Resumo:
En este trabajo se analiza el efecto de la selección de datos sobre las estimaciones de heredabilidad. Se estimó el valor de heredabilidad del tamaño de camada en una población porcina en la que los datos correspondientes a las cerdas más viejas eran una muestra seleccionada. Las estimaciones se obtuvieron usando distintos conjuntos de datos derivados de toda la información disponible. Esos conjunto de datos se compararon evaluando su capacidad predictiva. Se vio que las estimaciones de heredabilidad obtenidas utilizando todos los datos disponibles correspondían a valores infraestimados. También se simuló un carácter materno y se generó un conjunto de datos seleccionados eliminando aquellos correspondientes a las hembras sin padres conocidos. Distintos modelos, habitualmente empleados cuando no existe selección de registros, se consideraron para estimar el valor de heredabilidad. Los resultados mostraron que ninguno de esos modelos ofrecía estimaciones insesgadas. Sólo los modelos que tenían en cuenta el efecto de la selección sobre la media residual y la media y varianza genéticas ofrecían estimaciones poco sesgadas. Sin embargo, para poder aplicarlos se debe conocer la selección realizada. El problema de la selección de datos es difícil de abordar cuando se desconoce cual es el proceso de selección que se ha realizado en una población.
Resumo:
In this study, the evaluation of the accuracy and performance of a light detection and ranging (LIDAR) sensor for vegetation using distance and reflection measurements aiming to detect and discriminate maize plants and weeds from soil surface was done. The study continues a previous work carried out in a maize field in Spain with a LIDAR sensor using exclusively one index, the height profile. The current system uses a combination of the two mentioned indexes. The experiment was carried out in a maize field at growth stage 12–14, at 16 different locations selected to represent the widest possible density of three weeds: Echinochloa crus-galli (L.) P.Beauv., Lamium purpureum L., Galium aparine L.and Veronica persica Poir.. A terrestrial LIDAR sensor was mounted on a tripod pointing to the inter-row area, with its horizontal axis and the field of view pointing vertically downwards to the ground, scanning a vertical plane with the potential presence of vegetation. Immediately after the LIDAR data acquisition (distances and reflection measurements), actual heights of plants were estimated using an appropriate methodology. For that purpose, digital images were taken of each sampled area. Data showed a high correlation between LIDAR measured height and actual plant heights (R2 = 0.75). Binary logistic regression between weed presence/absence and the sensor readings (LIDAR height and reflection values) was used to validate the accuracy of the sensor. This permitted the discrimination of vegetation from the ground with an accuracy of up to 95%. In addition, a Canonical Discrimination Analysis (CDA) was able to discriminate mostly between soil and vegetation and, to a far lesser extent, between crop and weeds. The studied methodology arises as a good system for weed detection, which in combination with other principles, such as vision-based technologies, could improve the efficiency and accuracy of herbicide spraying.
Resumo:
In this work we will prove that SiC-based MIS capacitors can work in environments with extremely high concentrations of water vapor and still be sensitive to hydrogen, CO and hydrocarbons, making these devices suitable for monitoring the exhaust gases of hydrogen or hydrocarbons based fuel cells. Under the harshest conditions (45% of water vapor by volume ratio to nitrogen), Pt/TaOx/SiO2/SiC MIS capacitors are able to detect the presence of 1 ppm of hydrogen, 2 ppm of CO, 100 ppm of ethane or 20 ppm of ethene, concentrations that are far below the legal permissible exposure limits.
Resumo:
Mephedrone is a drug of abuse marketed as 'bath salts'. There are discrepancies concerning its long-term effects. We have investigated the neurotoxicity of mephedrone in mice following different exposition schedules. Schedule 1: four doses of 50 mg/kg. Schedule 2: four doses of 25 mg/kg. Schedule 3: three daily doses of 25 mg/kg, for two consecutive days. All schedules induced, in some animals, an aggressive behavior and hyperthermia as well as a decrease in weight gain. Mephedrone (schedule 1) induced dopaminergic and serotoninergic neurotoxicity that persisted 7 days after exposition. At a lower dose (schedule 2) only a transient dopaminergic injury was found. In the weekend consumption pattern (schedule 3), mephedrone induced dopamine and serotonin transporter loss that was accompanied by a decrease in tyrosine hydroxylase and tryptophan hydroxylase 2 expression one week after exposition. Also, mephedrone induced a depressive-like behavior, as well as a reduction in striatal D2 density, suggesting higher susceptibility to addictive drugs. In cultured cortical neurons, mephedrone induced a concentration-dependent cytotoxic effect. Using repeated doses for 2 days in an elevated ambient temperature we evidenced a loss of frontal cortex dopaminergic and hippocampal serotoninergic neuronal markers that suggest injuries at nerve endings.
Resumo:
Mephedrone is a drug of abuse marketed as 'bath salts'. There are discrepancies concerning its long-term effects. We have investigated the neurotoxicity of mephedrone in mice following different exposition schedules. Schedule 1: four doses of 50 mg/kg. Schedule 2: four doses of 25 mg/kg. Schedule 3: three daily doses of 25 mg/kg, for two consecutive days. All schedules induced, in some animals, an aggressive behavior and hyperthermia as well as a decrease in weight gain. Mephedrone (schedule 1) induced dopaminergic and serotoninergic neurotoxicity that persisted 7 days after exposition. At a lower dose (schedule 2) only a transient dopaminergic injury was found. In the weekend consumption pattern (schedule 3), mephedrone induced dopamine and serotonin transporter loss that was accompanied by a decrease in tyrosine hydroxylase and tryptophan hydroxylase 2 expression one week after exposition. Also, mephedrone induced a depressive-like behavior, as well as a reduction in striatal D2 density, suggesting higher susceptibility to addictive drugs. In cultured cortical neurons, mephedrone induced a concentration-dependent cytotoxic effect. Using repeated doses for 2 days in an elevated ambient temperature we evidenced a loss of frontal cortex dopaminergic and hippocampal serotoninergic neuronal markers that suggest injuries at nerve endings.
Resumo:
Aquest projecte s’emmarca dins de l’àmbit de la visió per computador, concretament en la utilització de dades de profunditat obtingudes a través d’un emissor i sensor de llum infraroja.El propòsit principal d’aquest projecte és mostrar com adaptar aquestes tecnologies, a l’abast de qualsevol particular, de forma que un usuari durant la pràctica d’una activitat esportiva concreta, rebi informació visual continua dels moviments i gestos incorrectes que està realitzant, en base a uns paràmetres prèviament establerts.L’objectiu d’aquest projecte consisteix en fer una lectura constant en temps real d’una persona practicant una selecció de diverses activitats esportives estàtiques utilitzant un sensor Kinect. A través de les dades obtingudes pel sensor Kinect i utilitzant les llibreries de “skeleton traking” proporcionades per Microsoft s’haurà d’interpretar les dades posturals obtingudes per cada tipus d’esport i indicar visualment i d’una manera intuïtiva els errors que està cometent en temps real, de manera que es vegi clarament a quina part del seu cos realitza un moviment incorrecte per tal de poder corregir-lo ràpidament. El entorn de desenvolupament que s’utilitza per desenvolupar aquesta aplicació es Microsoft Viusal Studio 2010.El llenguatge amb el qual es treballarà sobre Microsoft Visual Studio 2010 és C#
Resumo:
Nowadays, Wireless Sensor Networks (WSN) arealready a very important data source to obtain data about the environment. Thus, they are key to the creation of Cyber-Physical Systems (CPS). Given the popularity of P2P middlewares as ameans to efficiently process information and distribute services, being able to integrate them to WSN¿s is an interesting proposal. JXTA is a widely used P2P middleware that allows peers to easily exchange information, heavily relying on its main architectural highlight, the capability to organize peers with common interests into peer groups. However, right now, approaches to integrate WSNs to a JXTA network seldom take advantage of peer groups. For this reason, in this paper we present jxSensor, an integrationlayer for sensor motes which facilitates the deployment of CPS¿s under this architecture. This integration has been done taking into account JXTA¿s idiosyncrasies and proposing novel ideas,such as the Virtual Peer, a group of sensors that acts as a single entity within the peer group context.
Resumo:
The neuronal calcium sensor proteins GCAPs (guanylate cyclase activating proteins) switch between Ca2+-free and Ca2+-bound conformational states and confer calcium sensitivity to guanylate cyclase at retinal photoreceptor cells. They play a fundamental role in light adaptation by coupling the rate of cGMP synthesis to the intracellular concentration of calcium. Mutations in GCAPs lead to blindness. The importance of functional EF-hands in GCAP1 for photoreceptor cell integrity has been well established. Mutations in GCAP1 that diminish its Ca2+ binding affinity lead to cell damage by causing unabated cGMP synthesis and accumulation of toxic levels of free cGMP and Ca2+. We here investigate the relevance of GCAP2 functional EF-hands for photoreceptor cell integrity. By characterizing transgenic mice expressing a mutant form of GCAP2 with all EF-hands inactivated (EF(-)GCAP2), we show that GCAP2 locked in its Ca2+-free conformation leads to a rapid retinal degeneration that is not due to unabated cGMP synthesis. We unveil that when locked in its Ca2+-free conformation in vivo, GCAP2 is phosphorylated at Ser201 and results in phospho-dependent binding to the chaperone 14-3-3 and retention at the inner segment and proximal cell compartments. Accumulation of phosphorylated EF(-)GCAP2 at the inner segment results in severe toxicity. We show that in wildtype mice under physiological conditions, 50% of GCAP2 is phosphorylated correlating with the 50% of the protein being retained at the inner segment. Raising mice under constant light exposure, however, drastically increases the retention of GCAP2 in its Ca2+-free form at the inner segment. This study identifies a new mechanism governing GCAP2 subcellular distribution in vivo, closely related to disease. It also identifies a pathway by which a sustained reduction in intracellular free Ca2+ could result in photoreceptor damage, relevant for light damage and for those genetic disorders resulting in 'equivalent-light'' scenarios.
Resumo:
A novel unsymmetric dinucleating ligand (LN3N4) combining a tridentate and a tetradentate binding sites linked through a m-xylyl spacer was synthesized as ligand scaffold for preparing homo- and dimetallic complexes, where the two metal ions are bound in two different coordination environments. Site-selective binding of different metal ions is demonstrated. LN3N4 is able to discriminate between CuI and a complementary metal (M′ = CuI, ZnII, FeII, CuII, or GaIII) so that pure heterodimetallic complexes with a general formula [CuIM′(LN3N4)]n+ are synthesized. Reaction of the dicopper(I) complex [CuI 2(LN3N4)]2+ with O2 leads to the formation of two different copper-dioxygen (Cu2O2) intermolecular species (O and TP) between two copper atoms located in the same site from different complex molecules. Taking advantage of this feature, reaction of the heterodimetallic complexes [CuM′(LN3N4)]n+ with O2 at low temperature is used as a tool to determine the final position of the CuI center in the system because only one of the two Cu2O2 species is formed
Resumo:
The bis(mu-oxo) dicopper(III) species [Cu-III 2(mu-O)(2)(m-XYLMeAN)](2+) (1) promotes the electrophilic ortho-hydroxylation-defluorination of 2-fluorophenolates to give the corresponding catechols, a reaction that is not accomplishable with a (eta(2) : eta(2)-O-2) dicopper(II) complex. Isotopic labeling studies show that the incoming oxygen atom originates from the bis(mu-oxo) unit. Ortho-hydroxylation-defluorination occurs selectively in intramolecular competition with other ortho-substituents such as chlorine or bromine
Resumo:
We survey a number of papers that have focused on the construction of cross-country data sets on average years of schooling. We discuss the construction of the different series, compare their profiles and construct indicators of their information content. The discussion focuses on a sample of OECD countries but we also provide some results for a large non-OECD sample.
Resumo:
The immune system is the responsible for body integrity and prevention of external invasion. On one side, nanoparticles are no triggers that the immune system is prepared to detect, on the other side it is known that foreign bodies, not only bacteria, viruses and parasites, but also inorganic matter, can cause various pathologies such as silicosis, asbestosis or inflammatory reactions. Therefore, nanoparticles entering the body, after interaction with proteins, will be either recognized as self-agents or detected by the immune system, encompassing immunostimulation or immunosuppression responses. The nature of these interactions seems to be dictated not specially by the composition of the material but by modifications of NP coating (composition, surface charge and structure). Herein, we explore the use of gold nanoparticles as substrates to carry multifunctional ligands to manipulate the immune system in a controlled manner, from undetection to immunostimulation. Murine bone marrow macrophages can be activated with artificial nanometric objects consisting of a gold nanoparticle functionalized with peptides. In the presence of some conjugates, macrophage proliferation was stopped and pro-inflammatory cytokines were induced. The biochemical type of response depended on the type of conjugated peptide and was correlated with the degree of ordering in the peptide coating. These findings help to illustrate the basic requirements involved in medical NP conjugate design to either activate the immune system or hide from it, in order to reach their targets before being removed by phagocytes. Additionally, it opens up the possibility to modulate the immune response in order to suppress unwanted responses resulting from autoimmunity, or allergy or to stimulate protective responses against pathogens.