43 resultados para ANESTHETICS, Volatile: sevoflurane


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oxalic and oxamic acids are the ultimate and more persistent by-products of the degradation of N-aromatics by electrochemical advanced oxidation processes (EAOPs). In this paper, the kinetics and oxidative paths of these acids have been studied for several EAOPs using a boron-doped diamond (BDD) anode and a stainless steel or an air-diffusion cathode. Anodic oxidation (AO-BDD) in the presence of Fe2+ (AO-BDD-Fe2+) and under UVA irradiation (AO-BDD-Fe2+-UVA), along with electro-Fenton (EF-BDD), was tested. The oxidation of both acids and their iron complexes on BDD was clarified by cyclic voltammetry. AO-BDD allowed the overall mineralization of oxalic acid, but oxamic acid was removed much more slowly. Each acid underwent a similar decay in AO-BDD-Fe2+ and EFBDD, as expected if its iron complexes were not attacked by hydroxyl radicals in the bulk. The faster and total mineralization of both acids was achieved in AO-BDD-Fe2+-UVA due to the high photoactivity of their Fe(III) complexes that were continuously regenerated by oxidation of their Fe(II) complexes. Oxamic acid always released a larger proportion of NH4 + than NO3- ion, as well as volatile NOx species. Both acids were independently oxidized at the anode in AO-BDD, but in AO-BDD-Fe2+-UVA oxamic acid was more slowlydegraded as its content decreased, without significant effect on oxalic acid decay. The increase in current density enhanced the oxidation power of the latter method, with loss of efficiency. High Fe2+ contents inhibited the oxidation of Fe(II) complexes by the competitive oxidation of Fe2+ to Fe3+. Low current densities and Fe2+ contents are preferable to remove more efficiently these acids by the most potent AO-BDD-Fe2+-UVA method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

New methodologies for the analysis of volatile compoundsusing needle traps. Applications to breath, atmospheric andwater analysis. A new preconcentration technique has been developed for the analysis of volatile compounds based on the use of needle traps. These traps are based on stainless steel needles filled with one or more adsorbents, which allows the preconcentration of the anilities inside the trap by passing a gas flow through the needle. The parameters affecting the sorption/desorption process have been assessed (e.g. needle and liner dimensions, injector temperature, split less time, memory effects, and stability inside the needle). For liquid samples, four different sampling methodologies were studied, including passive and active sampling methods. The best results, considering the simplicity and sensitivity, are obtained by sampling the headspace volume using various cycles of a small and fix volume. Once the best conditions of analysis have been found, the method has been validated for gas and liquid samples. The results obtained show that needle traps are a good analytical methodology for the analysis of breath, environmental and liquid samples

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La sedación consciente durante el tratamiento odontológico y, en especial, durante el quirúrgico proporciona una mayor comodidad al paciente y al profesional contribuyendo a una mejor calidad de trabajo. Los fármacos más usados son las benzodiacepinas y entre ellos el midazolam está ganando gran aceptación por su rápido inicio de acción y rápida recuperación del paciente. Se dispone además del Dumazenil, un antagonista que puede revertir rápidamente una sobresedación. Otra alternativa es el uso del propofol al que se le atribuye la ventaja sobre el midazolam de tener una recuperación más rápida. Será necesario una adecuada monitorización durante todo el tratamiento y en el postoperatorio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Different compounds have been reported as biomarkers of a smoking habit, but, to date, there is no appropriate biomarker for tobacco-related exposure because the proposed chemicals seem to be nonspecific or they are only appropriate for short-term exposure. Moreover, conventional sampling methodologies require an invasive method because blood or urine samples are required. The use of a microtrap system coupled to gas chromatography–mass spectrometry analysis has been found to be very effective for the noninvasive analysis of volatile organic compounds in breath samples. The levels of benzene, 2,5-dimethylfuran, toluene, o-xylene, and m- p-xylene have been analyzed in breath samples obtained from 204 volunteers (100 smokers, 104 nonsmokers; 147 females, 57 males; ages 16 to 53 years). 2,5-Dimethylfuran was always below the limit of detection (0.005 ppbv) in the nonsmoker population and always detected in smokers independently of the smoking habits. Benzene was only an effective biomarker for medium and heavy smokers, and its level was affected by smoking habits. Regarding the levels of xylenes and toluene, they were only different in heavy smokers and after short-term exposure. The results obtained suggest that 2,5-dimethylfuran is a specific breath biomarker of smoking status independently of the smoking habits (e.g., short- and long-term exposure, light and heavy consumption), and so this compound might be useful as a biomarker of smoking exposure

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Air pollution has become an important issue worldwide due to its adverse health effects. Among the different air contaminants, volatile organic compounds (VOCs) are liquids or solids with a high vapor pressure at room temperature that are extremely dangerous for human health. Removal of these compounds can be achieved using nanomaterials with tailored properties such as carbon nanotubes. Methods: Vertically-aligned multiwall carbon nanotubes (CNTs) were successfully grown on quartz filters by means of plasma enhanced chemical vapor deposition (PECVD). Furthermore, a plasma treatment was performed in order to modify the surface properties of the CNTs. The adsorption/desorption processes of three chlorinated compounds (trichloroethylene, 1,2-dichlorobenzene and chloroform) on the CNTs were studied using mass spectrometry measurements with a residual gas analyzer. Results: The adsorption capability of the CNTs increased after functionalization of their surface with a water plasma treatment. In addition, it was found that the presence of aromatic rings, water solubility and polarity of the VOCs play an important role on the adsorption/desorption kinetics at the CNTs surface. Conclusions: This study demonstrates the applicability of CNTs deposited on quartz filters for the removal or selective detection of volatile organic compounds (VOCs). The presence of aromatic rings in VOCs results in π -stacking interactions with a significant increase of their adsorption. On the other hand, it was found that CNTs surface interactions increase with water solubility and polarity of the VOC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The concentration and ratio of terpenoids in the headspace volatile blend of plants have a fundamental role in the communication of plants and insects. The sesquiterpene (E)-nerolidol is one of the important volatiles with effect on beneficial carnivores for biologic pest management in the field. To optimize de novo biosynthesis and reliable and uniform emission of (E)-nerolidol, we engineered different steps of the (E)-nerolidol biosynthesis pathway in Arabidopsis thaliana. Introduction of a mitochondrial nerolidol synthase gene mediates de novo emission of (E)-nerolidol and linalool. Co-expression of the mitochondrial FPS1 and cytosolic HMGR1 increased the number of emitting transgenic plants (incidence rate) and the emission rate of both volatiles. No association between the emission rate of transgenic volatiles and their growth inhibitory effect could be established. (E)-Nerolidol was to a large extent metabolized to non-volatile conjugates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Carboxyl/cholinesterases (CCEs) are highly diversified in insects. These enzymes have a broad range of proposed functions, in neuro/developmental processes, dietary detoxification, insecticide resistance or hormone/pheromone degradation. As few functional data are available on purified or recombinant CCEs, the physiological role of most of these enzymes is unknown. Concerning their role in olfaction, only two CCEs able to metabolize sex pheromones have been functionally characterized in insects. These enzymes are only expressed in the male antennae, and secreted into the lumen of the pheromone-sensitive sensilla. CCEs able to hydrolyze other odorants than sex pheromones, such as plant volatiles, have not been identified. Methodology: In Spodoptera littoralis, a major crop pest, a diversity of antennal CCEs has been previously identified. We have employed here a combination of molecular biology, biochemistry and electrophysiology approaches to functionally characterize an intracellular CCE, SlCXE10, whose predominant expression in the olfactory sensilla suggested a role in olfaction. A recombinant protein was produced using the baculovirus system and we tested its catabolic properties towards a plant volatile and the sex pheromone components. Conclusion: We showed that SlCXE10 could efficiently hydrolyze a green leaf volatile and to a lesser extent the sex pheromone components. The transcript level in male antennae was also strongly induced by exposure to this plant odorant. In antennae, SlCXE10 expression was associated with sensilla responding to the sex pheromones and to plant odours. These results suggest that a CCE-based intracellular metabolism of odorants could occur in insect antennae, in addition to the extracellular metabolism occurring within the sensillar lumen. This is the first functional characterization of an Odorant- Degrading Enzyme active towards a host plant volatile.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To compare the anesthetic action of 0.5% bupivacaine in relation to 4% articaine, both with 1:200,000 epinephrine, in the surgical removal of lower third molars. As a secondary objective hemodynamic changes using both anesthetics were analyzed. Study Design: Triple-blind crossover randomized clinical trial. Eighteen patients underwent bilateral removal of impacted lower third molars using 0.5% bupivacaine or 4% articaine in two different appointments. Preoperative, intraoperative and postoperative variables were recorded. Differences were assessed with McNemar tests and repeated measures ANOVA tests. Results: Both solutions exhibited similar latency times and intraoperative efficacy. Statistical significant lower pain levels were observed with bupivacaine between the fifth (p=0.011) and the ninth (p=0.007) postoperative hours. Bupivacaine provided significantly longer lasting soft tissue anesthesia (p<0.05). Systolic blood pressure and heart rate values were significantly higher with articaine. Conclusions: Bupivacaine could be a valid alternative to articaine especially due to its early postoperative pain prevention ability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, a wrapper approach was applied to objectively select the most important variables related to two different anaerobic digestion imbalances, acidogenic states and foaming. This feature selection method, implemented in artificial neural networks (ANN), was performed using input and output data from a fully instrumented pilot plant (1 m 3 upflow fixed bed digester). Results for acidogenic states showed that pH, volatile fatty acids, and inflow rate were the most relevant variables. Results for foaming showed that inflow rate and total organic carbon were among the relevant variables, both of which were related to the feed loading of the digester. Because there is not a complete agreement on the causes of foaming, these results highlight the role of digester feeding patterns in the development of foaming

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aquest projecte es basa en l'aplicació de models de simulació de processos a un exemple d'empresa de producció i la seva adaptació en dimensió i recursos al mercat en un entorn de poca capacitat d'inversió i finançament, de forma que l'entorn de simulació digital aporti valor a la presa de decisions emmarcada en l'estratègia de l'empresa en cada escenari de mercat en que aquesta es trobi. Es realitza el treball sobre el cas d'una empresa, INNOVANAUTIC, dedicada a la innovació, desenvolupament i producció de sistemes de propulsió d'embarcacions. La simulació es una tècnica que permet optimitzar els processos, representant-ne i comprovant el funcionament dels processos, tant entorns físics, de producció com dels serveis associats o subcontractacions de diferents processos i els seus impactes en la disponibilitat de recursos, espais i terminis d'entrega, sense haver de recórrer a procediments de prova i error sobre sistemes reals que impliquen costos a tots nivells en l'empresa. Aquestes metodologies son habitualment emprades en d'altres països o també en el nostre país però en empreses de gran tamany. El present treball, emmarcat dins un entorn socioeconòmic convuls, amb grans limitacions financeres i de recursos per les empreses, demostra com la utilització d'eines de simulació és útil per a PIMES en aquest entorn i permet el dimensionament i la modelització dels processos de forma que es permeti trobar els punts òptims en els que l'empresa ha de donar un pas de creixement en alguns dels paràmetres. La metodologia amb que s'elabora el present treball es la de plantejar una simulació complerta del procés, i definir diversos escenaris de mercat per als productes fabricats, cercant els punt òptims de canvi de dimensió de l'empresa atenent a espai físic, sotscontractació de processos, personal i recursos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A capillary microtrap thermal desorption module is developed for near real-time analysis of volatile organic compounds (VOCs) at sub-ppbv levels in air samples. The device allows the direct injection of the thermally desorbed VOCs into a chromatographic column. It does not use a second cryotrap to focalize the adsorbed compounds before entering the separation column so reducing the formation of artifacts. The connection of the microtrap to a GC–MS allows the quantitative determination of VOCs in less than 40 min with detection limits of between 5 and 10 pptv (25 °C and 760 mmHg), which correspond to 19–43 ng m−3, using sampling volumes of 775 cm3. The microtrap is applied to the analysis of environmental air contamination in different laboratories of our faculty. The results obtained indicate that most volatile compounds are easily diffused through the air and that they also may contaminate the surrounding areas when the habitual safety precautions (e.g., working under fume hoods) are used during the manipulation of solvents. The application of the microtrap to the analysis of VOCs in breath samples suggest that 2,5-dimethylfuran may be a strong indicator of a person's smoking status

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Different compounds have been reported as biomarkers of a smoking habit, but, to date, there is no appropriate biomarker for tobacco-related exposure because the proposed chemicals seem to be nonspecific or they are only appropriate for short-term exposure. Moreover, conventional sampling methodologies require an invasive method because blood or urine samples are required. The use of a microtrap system coupled to gas chromatography–mass spectrometry analysis has been found to be very effective for the noninvasive analysis of volatile organic compounds in breath samples. The levels of benzene, 2,5-dimethylfuran, toluene, o-xylene, and m- p-xylene have been analyzed in breath samples obtained from 204 volunteers (100 smokers, 104 nonsmokers; 147 females, 57 males; ages 16 to 53 years). 2,5-Dimethylfuran was always below the limit of detection (0.005 ppbv) in the nonsmoker population and always detected in smokers independently of the smoking habits. Benzene was only an effective biomarker for medium and heavy smokers, and its level was affected by smoking habits. Regarding the levels of xylenes and toluene, they were only different in heavy smokers and after short-term exposure. The results obtained suggest that 2,5-dimethylfuran is a specific breath biomarker of smoking status independently of the smoking habits (e.g., short- and long-term exposure, light and heavy consumption), and so this compound might be useful as a biomarker of smoking exposure

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is an increasing interest in the use of breath analysis for monitoring human physiology and exposure to toxic substances or environmental pollutants. This review focuses on the current status of the sampling procedures, collection devices and sample-enrichment methodologies used for exhaled breath-vapor analysis. We discuss the different parameters affecting each of the above steps, taking into account the requirements for breath analysis in exposure assessments and the need to analyze target compounds at sub-ppbv levels. Finally, we summarize the practical applications of exposure analysis in the past two decades