21 resultados para Wireless capsule endoscopy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabajo de final de carrera enfocado a la simulación de una WSN (Wireless Sensors Networks) mediante el programa Contiki 2.7 y el SO Ubuntu. La idea global del proyecto es conseguir simular un entorno con nodos sensores y, a posteriori, comprobar su correcto funcionamiento en motas reales, comprobando los resultados obtenidos en ambos entornos. De esta manera se puede facilitar la puesta en marcha de este tipo de redes inalámbricas en una aplicación real.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Testbeds are a stage between the simulation and the production stages. To this end they must be as close as possible to production environments (i.e. real hardware, on the field deployments) while also keeping the traits of experimentation facilities (i.e. fault tolerance, ease of deployment, testing and data collection). This paper presents WiBed, a FOSS platform for WiFi testbeds based on OpenWRT Linux made to run oncommodity IEEE802.11 WiFi routers part of the Community-lab.net project, a global testbed for Community networks. WiBedhas been designed to support realistic low layer network exper-iments (according to the OSI model). This work recolects thedetails of the architecture, design and implementation of WiBed consolidated during its operation as a testbed. In addition to a set of routing experimentation results obtained during the Wireless Battlemesh v7 where WiBed was used as testbed platform.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wireless Sensor Networks (WSN) are formed by nodes with limited computational and power resources. WSNs are finding an increasing number of applications, both civilian and military, most of which require security for the sensed data being collected by the base station from remote sensor nodes. In addition, when many sensor nodes transmit to the base station, the implosion problem arises. Providing security measures and implosion-resistance in a resource-limited environment is a real challenge. This article reviews the aggregation strategies proposed in the literature to handle the bandwidth and security problems related to many-to-one transmission in WSNs. Recent contributions to secure lossless many-to-one communication developed by the authors in the context of several Spanish-funded projects are surveyed. Ongoing work on the secure lossy many-to-one communication is also sketched.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents WiBed, a FOSS platform for WiFi testbeds based on OpenWRT Linux made to run on commodity IEEE802.11 WiFi routers part of the Community-lab.net project, a global testbed for Community networks. WiBed has been designed to support realistic low layer network experiments (according to the OSI model). This work recolects the details of the architecture, design and implementation of WiBed consolidated during its operation as a testbed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SOSoW (SOS Over Wireless) és una aplicació Android que ajuda a ser localitzat en situacions d'emergència extremes, fent ús únicament dels propis sensors de l'smartphone i sense necessitat d'internet ("offline").

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capsule application of Diamidino Yellow (DY) to the cut end of the sciatic nerve immediately followed by capsule application of Fast Blue (FB) resulted in approximate to 95% double-labelled dorsal root ganglion neurones (DRGn) and motoneurones (Mn). Nerve injection of DY followed either immediately or 2 months later by capsule application of FB resulted in approximate to 90% double-labelled DRGn and Mn, indicating that DY and FB label similar populations of DRGn and Mn, and that insignificant DY fading occurred during this period. Inversing the order of application, however, i.e. nerve injection of FB followed immediately by capsule application of DY, resulted in double labelling in only approximate to 10% of the DRGn and Mn. These percentages increased to 70% of the DRGn and 60% of the Mn when the FB injection was followed 1 or 2 months after by the DY application, indicating that DY uptake is blocked by recent administration of FB. The results indicate that DY and FB might be useful for sequential labelling before and after nerve injury as a tool to investigate the accuracy of sensory and motor regeneration.