79 resultados para Stream flow


Relevância:

20.00% 20.00%

Publicador:

Resumo:

From a managerial point of view, the more effcient, simple, and parameter-free (ESP) an algorithm is, the more likely it will be used in practice for solving real-life problems. Following this principle, an ESP algorithm for solving the Permutation Flowshop Sequencing Problem (PFSP) is proposed in this article. Using an Iterated Local Search (ILS) framework, the so-called ILS-ESP algorithm is able to compete in performance with other well-known ILS-based approaches, which are considered among the most effcient algorithms for the PFSP. However, while other similar approaches still employ several parameters that can affect their performance if not properly chosen, our algorithm does not require any particular fine-tuning process since it uses basic "common sense" rules for the local search, perturbation, and acceptance criterion stages of the ILS metaheuristic. Our approach defines a new operator for the ILS perturbation process, a new acceptance criterion based on extremely simple and transparent rules, and a biased randomization process of the initial solution to randomly generate different alternative initial solutions of similar quality -which is attained by applying a biased randomization to a classical PFSP heuristic. This diversification of the initial solution aims at avoiding poorly designed starting points and, thus, allows the methodology to take advantage of current trends in parallel and distributed computing. A set of extensive tests, based on literature benchmarks, has been carried out in order to validate our algorithm and compare it against other approaches. These tests show that our parameter-free algorithm is able to compete with state-of-the-art metaheuristics for the PFSP. Also, the experiments show that, when using parallel computing, it is possible to improve the top ILS-based metaheuristic by just incorporating to it our biased randomization process with a high-quality pseudo-random number generator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En la recerca d’eines que suposen la interactivitat com a punt clau en el model de comunicació, la present investi- gació aborda l’ús de videojocs amb contingut publicitari o “advergaming” com a punt central d’estudi i pretén es- tablir els factors que determinen una experiència de joc òptima a través de l’ús de pantalles digitals com a mitjà difusor d’aquest tipus de contingut. Parlarem de “flow experience” o teoria de la psicologia po- sitiva segons el seu creador i precursor Mihály Csíkszent- mihályi, i serà la perspectiva des de la qual pretenem desenvolupar aquest estudi, entenent el “flow experience” com l’estat òptim o nivell més alt d’experiència d’usuari que es pot assolir durant una activitat

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com a resultat de les politiques i estratègies de col·laboració entre la universitat de Vic i de l’hospital i de la voluntat de realitzar activitats formatives conjuntes , s’estableix un línia de treball orientada a l’estudi i anàlisi de la situació logística interna actual del laboratori d’anàlisis clíniques de l’Hospital General de Vic. El treball es centra en el procés intern del laboratori i l’abast de l’estudi es troba limitat a les àrees especifiques d’hematologia i coagulació i bioquímica. D’aquestes dues àrees el treball realitza un estudi exhaustiu del seu procés intern, identifica les seves activitats i la seva metodologia de treball amb l’objectiu d’elaborar el Value Stream Map de cadascuna de les àrees. Les àrees de Microbiologia, Banc de Sang i Urgències resten fora d’aquest estudi exhaustiu tot i que són presents en el treball per la inevitable interacció que tenen en la globalitat del procés. El treball es centra bàsicament en els processos automatitzats tot i que els processos que es duen a terme en el laboratori són tant automatitzats com manuals. També es limita al sistema productiu intern del laboratori tot i la interacció que té aquest sistema intern amb altres centres productius del sistema com ara són els centres d’atenció primària, els diversos hospitals i centres d’atenció sociosanitària. El laboratori es troba immers en el moment de l’elaboració d’aquest treball en un situació de canvi i millora del seus processos interns que consisteixen principalment en la substitució de part la maquinària actual que obliguen a la definició d’un nou layout i d’una nova distribució de la producció a cada màquina. A nivell extern també s’estan produint millores en el sistema informàtic de gestió que afecten a part del seu procés. L’objectiu del treball és donar visibilitat total al procés de logística interna actual del laboratori, identificant clarament com són i quina seqüència tenen els processos logístics interns i els mètodes de treball actuals, tant de recursos màquina com recursos persona, per poder identificar sota una perspectiva de generació de valor, aquells punts concrets de la logística interna que poden ser millorats en quant a eficiència i productivitat amb l’objectiu que un cop identificats es puguin emprendre accions i/o projectes de millora. El treball finalitza amb un anàlisis final del procés logística interna des d’una òptica Lean. Per fer-ho, identifica aquelles activitats que no aporten valor al procés o MUDA i les classifica en set categories i es realitzen diverses propostes de millora com són la implantació d’un flux continu , anivellat i basat en un concepte pull , identifica activitats que poden ser estandarditzades i/o simplificades i proposa modificacions en les infraestructures físiques per donar major visibilitat al procés. L’aspecte humà del procés es planteja des d’un punt de vist de metodologia, formació, comunicació i aplicació de les 5S.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present some results attained with different algorithms for the Fm|block|Cmax problem using as experimental data the well-known Taillard instances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffuse flow velocimetry (DFV) is introduced as a new, noninvasive, optical technique for measuring the velocity of diffuse hydrothermal flow. The technique uses images of a motionless, random medium (e.g.,rocks) obtained through the lens of a moving refraction index anomaly (e.g., a hot upwelling). The method works in two stages. First, the changes in apparent background deformation are calculated using particle image velocimetry (PIV). The deformation vectors are determined by a cross correlation of pixel intensities across consecutive images. Second, the 2-D velocity field is calculated by cross correlating the deformation vectors between consecutive PIV calculations. The accuracy of the method is tested with laboratory and numerical experiments of a laminar, axisymmetric plume in fluids with both constant and temperaturedependent viscosity. Results show that average RMS errors are ∼5%–7% and are most accurate in regions of pervasive apparent background deformation which is commonly encountered in regions of diffuse hydrothermal flow. The method is applied to a 25 s video sequence of diffuse flow from a small fracture captured during the Bathyluck’09 cruise to the Lucky Strike hydrothermal field (September 2009). The velocities of the ∼10°C–15°C effluent reach ∼5.5 cm/s, in strong agreement with previous measurements of diffuse flow. DFV is found to be most accurate for approximately 2‐D flows where background objects have a small spatial scale, such as sand or gravel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large phasic variations of respiratory mechanical impedance (Zrs) have been observed during induced expiratory flow limitation (EFL) (M. Vassiliou, R. Peslin, C. Saunier, and C. Duvivier. Eur. Respir. J. 9: 779-786, 1996). To clarify the meaning of Zrs during EFL, we have measured from 5 to 30 Hz the input impedance (Zin) of mechanical analogues of the respiratory system, including flow-limiting elements (FLE) made of easily collapsible rubber tubing. The pressures upstream (Pus) and downstream (Pds) from the FLE were controlled and systematically varied. Maximal flow (Vmax) increased linearly with Pus, was close to the value predicted from wave-speed theory, and was obtained for Pus-Pds of 4-6 hPa. The real part of Zin started increasing abruptly with flow (V) >85%Vmax and either further increased or suddenly decreased in the vicinity of V¿max. The imaginary part of Zin decreased markedly and suddenly above 95%Vmax. Similar variations of Zin during EFL were seen with an analogue that mimicked the changes of airway transmural pressure during breathing. After pressure andV measurements upstream and downstream from the FLE were combined, the latter was analyzed in terms of a serial (Zs) and a shunt (Zp) compartment. Zs was consistent with a large resistance and inertance, and Zp with a mainly elastic element having an elastance close to that of the tube walls. We conclude that Zrs data during EFL mainly reflect the properties of the FLE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Substantial collective flow is observed in collisions between lead nuclei at Large Hadron Collider (LHC) as evidenced by the azimuthal correlations in the transverse momentum distributions of the produced particles. Our calculations indicate that the global v1-flow, which at RHIC peaked at negative rapidities (named third flow component or antiflow), now at LHC is going to turn toward forward rapidities (to the same side and direction as the projectile residue). Potentially this can provide a sensitive barometer to estimate the pressure and transport properties of the quark-gluon plasma. Our calculations also take into account the initial state center-of-mass rapidity fluctuations, and demonstrate that these are crucial for v1 simulations. In order to better study the transverse momentum flow dependence we suggest a new "symmetrized" v1S(pt) function, and we also propose a new method to disentangle global v1 flow from the contribution generated by the random fluctuations in the initial state. This will enhance the possibilities of studying the collective Global v1 flow both at the STAR Beam Energy Scan program and at LHC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A controlled perturbation is introduced into the Saffman-Taylor flow problem by adding a gradient to the gap of a Hele-Shaw cell. The stability of the single-finger steady state was found to be strongly affected by such a perturbation. Compared with patterns in a standard Hele-Shaw cell, the single Saffman-Taylor finger was stabilized or destabilized according to the sign of the gap gradient. While a linear stability analysis shows that this perturbation should have a negligible effect on the early-stage pattern formation, the experimental data indicate that the characteristic length for the initial breakup of a flat interface has been changed by the perturbation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that a magnetic dipole in a shear flow under the action of an oscillating magnetic field displays stochastic resonance in the linear response regime. To this end, we compute the classical quantifiers of stochastic resonance, i.e., the signal to noise ratio, the escape time distribution, and the mean first passage time. We also discuss the limitations and role of the linear response theory in its applications to the theory of stochastic resonance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental quasi-two-dimensional Zn electrodeposits are grown under forced convection conditions. Large-scale effects, with preferential growth towards the impinging flow, together with small-scale roughness suppression effects are evidenced and separately analyzed by using two different radial cell configurations. Interpretations are given in terms of primary concepts concerning current and concentration distributions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the experimental data of Paret and Tabeling [Phys. Rev. Lett. 79, 4162 (1997)] we consider in detail the dispersion of particle pairs by a two-dimensional turbulent flow and its relation to the kinematic properties of the velocity field. We show that the mean square separation of a pair of particles is governed by rather rare, extreme events and that the majority of initially close pairs are not dispersed by the flow. Another manifestation of the same effect is the fact that the dispersion of an initially dense cluster is not the result of homogeneously spreading the particles within the whole system. Instead it proceeds through a splitting into smaller but also dense clusters. The statistical nature of this effect is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study fracturelike flow instabilities that arise when water is injected into a Hele-Shaw cell filled with aqueous solutions of associating polymers. We explore various polymer architectures, molecular weights, and solution concentrations. Simultaneous measurements of the finger tip velocity and of the pressure at the injection point allow us to describe the dynamics of the finger in terms of the finger mobility, which relates the velocity to the pressure gradient. The flow discontinuities, characterized by jumps in the finger tip velocity, which are observed in experiments with some of the polymer solutions, can be modeled by using a nonmonotonic dependence between a characteristic shear stress and the shear rate at the tip of the finger. A simple model, which is based on a viscosity function containing both a Newtonian and a non-Newtonian component, and which predicts nonmonotonic regions when the non-Newtonian component of the viscosity dominates, is shown to agree with the experimental data.