24 resultados para Limits of Sets


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The overwintering of the Mediterranean fruit fly (medfly), Ceratitis capitata (Wiedemann) at the northern limits of its geographic distribution is not yet well known. With the aim of estimating the survival rate of medfly adults in northeast Spain under natural winter conditions, a two-winter-season trial was carried out. A control was carried out in a climatic chamber at 25°C. The results showed that medfly adults were unable to survive the entire winter season in the Girona area. Climatic conditions, including the daily minimum temperature, daily maximum temperature and the high rainfall, appeared to be involved in adult mortality in winter.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Head space gas chromatography with flame-ionization detection (HS-GC-FID), ancl purge and trap gas chromatography-mass spectrometry (P&T-GC-MS) have been used to determine methyl-tert-butyl ether (MTBE) and benzene, toluene, and the ylenes (BTEX) in groundwater. In the work discussed in this paper measures of quality, e.g. recovery (94-111%), precision (4.6 - 12.2%), limits of detection (0.3 - 5.7 I~g L 1 for HS and 0.001 I~g L 1 for PT), and robust-ness, for both methods were compared. In addition, for purposes of comparison, groundwater samples from areas suffering from odor problems because of fuel spillage and tank leakage were analyzed by use of both techniques. For high concentration levels there was good correlation between results from both methods.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this work methods for the multiresidue determination of the series of quinolones include in the European regulation in food of animal origin are de veloped and validated in line with Commission Decision 2002/657/EC in terms of linearity, decision limit, capability detection, precision and stability. Mult iresidue methods were established to allow the determination of quinolones covered by EU legislation in 2377/90/EC in muscle of chicken, turkey, pig and cow, plasma of cow and pig, liver of pig and milk of cow. First an extraction step was optimized and a SPE step was applied to clean!up and preconcentrate quinolones prior to their separation by CE or LC and determination by CE!UV, LC!UV, LC!Fl, LC!MS with different ion sources (ESI ,ApCI) and different mass analyser (Q, ToF) and LC!E SI!QqQ tandem mass spectrometry. The limits of quantification obtained are always lower than Maxim um Residue Limit (MRL) established by EU for quinolones in animal products and they can be applied to the control of quinolones in foodstuffs of animal origin . Finally the proposed methods were applied to determine quinolones in samples of turkey and pig muscle, pig plasma and milk of cow. Excellent quality parameters and reduced time of analysis were obtained when LC!ESI!MS/MS is used, although the others techniques presented too satisfactory results.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The present work describes the development of a fast and robust analytical method for the determination of 53 antibiotic residues, covering various chemical groups and some of their metabolites, in environmental matrices that are considered important sources of antibiotic pollution, namely hospital and urban wastewaters, as well as in river waters. The method is based on automated off-line solid phase extraction (SPE) followed by ultra-high-performance liquid chromatography coupled to quadrupole linear ion trap tandem mass spectrometry (UHPLC–QqLIT). For unequivocal identification and confirmation, and in order to fulfill EU guidelines, two selected reaction monitoring (SRM) transitions per compound are monitored (the most intense one is used for quantification and the second one for confirmation). Quantification of target antibiotics is performed by the internal standard approach, using one isotopically labeled compound for each chemical group, in order to correct matrix effects. The main advantages of the method are automation and speed-up of sample preparation, by the reduction of extraction volumes for all matrices, the fast separation of a wide spectrum of antibiotics by using ultra-high-performance liquid chromatography, its sensitivity (limits of detection in the low ng/L range) and selectivity (due to the use of tandem mass spectrometry) The inclusion of β-lactam antibiotics (penicillins and cephalosporins), which are compounds difficult to analyze in multi-residue methods due to their instability in water matrices, and some antibiotics metabolites are other important benefits of the method developed. As part of the validation procedure, the method developed was applied to the analysis of antibiotics residues in hospital, urban influent and effluent wastewaters as well as in river water samples

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Combining headspace (HS) sampling with a needle-trap device (NTD) to determine priority volatile organic compounds (VOCs) in water samples results in improved sensitivity and efficiency when compared to conventional static HS sampling. A 22 gauge stainless steel, 51-mm needle packed with Tenax TA and Carboxen 1000 particles is used as the NTD. Three different HS-NTD sampling methodologies are evaluated and all give limits of detection for the target VOCs in the ng L−1 range. Active (purge-and-trap) HS-NTD sampling is found to give the best sensitivity but requires exhaustive control of the sampling conditions. The use of the NTD to collect the headspace gas sample results in a combined adsorption/desorption mechanism. The testing of different temperatures for the HS thermostating reveals a greater desorption effect when the sample is allowed to diffuse, whether passively or actively, through the sorbent particles. The limits of detection obtained in the simplest sampling methodology, static HS-NTD (5 mL aqueous sample in 20 mL HS vials, thermostating at 50 °C for 30 min with agitation), are sufficiently low as to permit its application to the analysis of 18 priority VOCs in natural and waste waters. In all cases compounds were detected below regulated levels

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work presents a comparison between three analytical methods developed for the simultaneous determination of eight quinolones regulated by the European Union (marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, difloxacin, sarafloxacin, oxolinic acid and flumequine) in pig muscle, using liquid chromatography with fluorescence detection (LC-FD), liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The procedures involve an extraction of the quinolones from the tissues, a step for clean-up and preconcentration of the analytes by solid-phase extraction and a subsequent liquid chromatographic analysis. The limits of detection of the methods ranged from 0.1 to 2.1 ng g−1 using LC-FD, from 0.3 to 1.8 using LC-MS and from 0.2 to 0.3 using LC-MS/MS, while inter- and intra-day variability was under 15 % in all cases. Most of those data are notably lower than the maximum residue limits established by the European Union for quinolones in pig tissues. The methods have been applied for the determination of quinolones in six different commercial pig muscle samples purchased in different supermarkets located in the city of Granada (south-east Spain).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A capillary microtrap thermal desorption module is developed for near real-time analysis of volatile organic compounds (VOCs) at sub-ppbv levels in air samples. The device allows the direct injection of the thermally desorbed VOCs into a chromatographic column. It does not use a second cryotrap to focalize the adsorbed compounds before entering the separation column so reducing the formation of artifacts. The connection of the microtrap to a GC–MS allows the quantitative determination of VOCs in less than 40 min with detection limits of between 5 and 10 pptv (25 °C and 760 mmHg), which correspond to 19–43 ng m−3, using sampling volumes of 775 cm3. The microtrap is applied to the analysis of environmental air contamination in different laboratories of our faculty. The results obtained indicate that most volatile compounds are easily diffused through the air and that they also may contaminate the surrounding areas when the habitual safety precautions (e.g., working under fume hoods) are used during the manipulation of solvents. The application of the microtrap to the analysis of VOCs in breath samples suggest that 2,5-dimethylfuran may be a strong indicator of a person's smoking status

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A spectrofluorometric method has been developed and validated for the determination of gemfibrozil. The method is based on the excitation and emission capacities of gemfibrozil with excitation and emission wavelengths of 276 and 304 nm respectively. This method allows de determination of the drug in a self-nanoemulsifying drug delivery system (SNEDDS) for improve its intestinal absorption. Results obtained showed linear relationships with good correlation coefficients (r(2)>0.999) and low limits of detection and quantification (LOD of 0.075 μg mL(-1) and LOQ of 0.226 μg mL(-1)) in the range of 0.2-5 μg mL(-1), equally this method showed a good robustness and stability. Thus the amounts of gemfibrozil released from SNEDDS contained in gastro resistant hard gelatine capsules were analysed, and release studies could be performed satisfactorily.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We introduce a new notion for the deformation of Gabor systems. Such deformations are in general nonlinear and, in particular, include the standard jitter error and linear deformations of phase space. With this new notion we prove a strong deformation result for Gabor frames and Gabor Riesz sequences that covers the known perturbation and deformation results. Our proof of the deformation theorem requires a new characterization of Gabor frames and Gabor Riesz sequences. It is in the style of Beurling's characterization of sets of sampling for bandlimited functions and extends significantly the known characterization of Gabor frames 'without inequalities' from lattices to non-uniform sets.