17 resultados para Flow-performance relationship
Resumo:
Several studies have suggested a bilingual advantage in executive functions, presumably due to bilinguals' massive practice with language switching that requires executive resources, but the results are still somewhat controversial. Previous studies are also plagued by the inherent limitations of a natural groups design where the participant groups are bound to differ in many ways in addition to the variable used to classify them. In an attempt to introduce a complementary analysis approach, we employed multiple regression to study whether the performance of 30- to 75-year-old FinnishSwedish bilinguals (N = 38) on tasks measuring different executive functions (inhibition, updating, and set shifting) could be predicted by the frequency of language switches in everyday life (as measured by a language switching questionnaire), L2 age of acquisition, or by the self-estimated degree of use of both languages in everyday life. Most consistent effects were found for the set shifting task where a higher rate of everyday language switches was related to a smaller mixing cost in errors. Mixing cost is thought to reflect top-down management of competing task sets, thus resembling the bilingual situation where decisions of which language to use has to be made in each conversation. These findings provide additional support to the idea that some executive functions in bilinguals are affected by a lifelong experience in language switching and, perhaps even more importantly, suggest a complementary approach to the study of this issue.
Resumo:
Two experimental studies evaluated the effect of aerobic and membrane aeration changes on sludge properties, biological nutrient removal and filtration processes in a pilot plant membrane bioreactor. The optimal operating conditions were found at an aerobic dissolved oxygen set-point (DO) of 0.5mgO2L-1 and a membrane specific aeration demand (SADm) of 1mh-1, where membrane aeration can be used for nitrification. Under these conditions, a total flow reduction of 42% was achieved (75% energy reduction) without compromising nutrient removal efficiencies, maintaining sludge characteristics and controlled filtration. Below these optimal operating conditions, the nutrient removal efficiency was reduced, increasing 20% for soluble microbial products, 14% for capillarity suction time and reducing a 15% for filterability. Below this DO set-point, fouling increased with a transmembrane pressure 75% higher. SADm below 1mh-1 doubled the values of transmembrane pressure, without recovery after achieving the initial conditions