22 resultados para Flow between Eccentric Annulus
Resumo:
Background: The aim of this study was to evaluate how hospital capacity was managed focusing on standardizing the admission and discharge processes. Methods: This study was set in a 900-bed university affiliated hospital of the National Health Service, near Barcelona (Spain). This is a cross-sectional study of a set of interventions which were gradually implemented between April and December 2008. Mainly, they were focused on standardizing the admission and discharge processes to improve patient flow. Primary administrative data was obtained from the 2007 and 2009 Hospital Database. Main outcome measures were median length of stay, percentage of planned discharges, number of surgery cancellations and median number of delayed emergency admissions at 8:00¿am. For statistical bivariate analysis, we used a Chi-squared for linear trend for qualitative variables and a Wilcoxon signed ranks test and a Mann¿Whitney test for non-normal continuous variables. Results:The median patients' global length of stay was 8.56 days in 2007 and 7.93 days in 2009 (p<0.051). The percentage of patients admitted the same day as surgery increased from 64.87% in 2007 to 86.01% in 2009 (p<0.05). The number of cancelled interventions due to lack of beds was 216 patients in 2007 and 42 patients in 2009. The median number of planned discharges went from 43.05% in 2007 to 86.01% in 2009 (p<0.01). The median number of emergency patients waiting for an in-hospital bed at 8:00¿am was 5 patients in 2007 and 3 patients in 2009 (p<0.01). Conclusions: In conclusion, standardization of admission and discharge processes are largely in our control. There is a significant opportunity to create important benefits for increasing bed capacity and hospital throughput.
Resumo:
Substantial collective flow is observed in collisions between lead nuclei at Large Hadron Collider (LHC) as evidenced by the azimuthal correlations in the transverse momentum distributions of the produced particles. Our calculations indicate that the global v1-flow, which at RHIC peaked at negative rapidities (named third flow component or antiflow), now at LHC is going to turn toward forward rapidities (to the same side and direction as the projectile residue). Potentially this can provide a sensitive barometer to estimate the pressure and transport properties of the quark-gluon plasma. Our calculations also take into account the initial state center-of-mass rapidity fluctuations, and demonstrate that these are crucial for v1 simulations. In order to better study the transverse momentum flow dependence we suggest a new"symmetrized" vS1(pt) function, and we also propose a new method to disentangle global v1 flow from the contribution generated by the random fluctuations in the initial state. This will enhance the possibilities of studying the collective Global v1 flow both at the STAR Beam Energy Scan program and at LHC.
Resumo:
Objetivou-se com este trabalho avaliar a distribuição de líquido da ponta de pulverização com indução de ar e jato excêntrico AIUB 8502 sob diferentes condições operacionais. Foram avaliados perfil individual, vazão, ângulo de abertura do jato, faixa de aplicação e distribuição volumétrica simulada de duas pontas AIUB 8502 nas pressões de trabalho de 200, 300, 400 e 500 kPa, altura de 30, 40 e 50 cm em relação ao alvo e espaçamento entre pontas de 30 a 100 cm. Todas as análises foram realizadas seguindo a norma ISSO 5682-1, com algumas adaptações. A ponta apresentou distribuição de líquido excêntrica com um lado descontínuo e extremidade oposta excêntrica, com queda abrupta do volume de líquido. À medida que se aumentou a altura da barra e a pressão de trabalho, alongou-se o perfil do jato. O maior número de configurações uniformes foi obtido na altura de 50 cm, decrescendo nas alturas de 40 e 30 cm. A vazão e o ângulo do jato excêntrico aumentaram com o incremento na pressão, não havendo diferença entre o ângulo do jato descontínuo e o total entre as pressões de 400 e 500 kPa e de 200 e 300 kPa.
Resumo:
Three models of flow resistance (a Keulegan-type logarithmic law and two models developed for large-scale roughness conditions: the full logarithmic law and a model based on an inflectional velocity profile) were calibrated, validated and compared using an extensive database (N = 1,533) from rivers and flumes, representative of a wide hydraulic and geomorphologic range in the field of gravel-bed and mountain channels. It is preferable to apply the model based on an inflectional velocity profile in the relative submergence (y/d90) interval between 0.5 and 15, while the full logarithmic law is preferable for values below 0.5. For high relative submergence, above 15, either the logarithmic law or the full logarithmic law can be applied. The models fitted to the coarser percentiles are preferable to those fitted to the median diameter, owing to the higher explanatory power achieved by setting a model, the smaller difference in the goodness-of-fit between the different models and the lower influence of the origin of the data (river or flume).
Resumo:
Gene flow (defined as allele exchange between populations) and gene flux (defined as allele exchange during meiosis in heterokaryotypic females) are important factors decreasing genetic differentiation between populations and inversions. Many chromosomal inversions are under strong selection and their role in recombination reduction enhances the maintenance of their genetic distinctness. Here we analyze levels and patterns of nucleotide diversity, selection and demographic history, using 37 individuals of Drosophila subobscura from Mount Parnes (Greece) and Barcelona (Spain). Our sampling focused on two frequent O-chromosome arrangements that differ by two overlapping inversions (OST and O3+4), which are differentially adapted to the environment as observed by their opposing latitudinal clines in inversion frequencies. The six analyzed genes (Pif1A, Abi, Sqd, Yrt, Atpa and Fmr1) were selected for their location across the O-chromosome and their implication in thermal adaptation. Despite the extensive gene flux detected outside the inverted region, significant genetic differentiation between both arrangements was found inside it. However, high levels of gene flow were detected for all six genes when comparing the same arrangement among populations. These results suggest that the adaptive value of inversions is maintained, regardless of the lack of genetic differentiation within arrangements from different populations, and thus favors the Local Adaptation hypothesis over the Coadapted Genome hypothesis as the basis of the selection acting on inversions in these populations.
Resumo:
Extension of shelf life and preservation of products are both very important for the food industry. However, just as with other processes, speed and higher manufacturing performance are also beneficial. Although microwave heating is utilized in a number of industrial processes, there are many unanswered questions about its effects on foods. Here we analyze whether the effects of microwave heating with continuous flow are equivalent to those of traditional heat transfer methods. In our study, the effects of heating of liquid foods by conventional and continuous flow microwave heating were studied. Among other properties, we compared the stability of the liquid foods between the two heat treatments. Our goal was to determine whether the continuous flow microwave heating and the conventional heating methods have the same effects on the liquid foods, and, therefore, whether microwave heat treatment can effectively replace conventional heat treatments. We have compared the colour, separation phenomena of the samples treated by different methods. For milk, we also monitored the total viable cell count, for orange juice, vitamin C contents in addition to the taste of the product by sensory analysis. The majority of the results indicate that the circulating coil microwave method used here is equivalent to the conventional heating method based on thermal conduction and convection. However, some results in the analysis of the milk samples show clear differences between heat transfer methods. According to our results, the colour parameters (lightness, red-green and blue-yellow values) of the microwave treated samples differed not only from the untreated control, but also from the traditional heat treated samples. The differences are visually undetectable, however, they become evident through analytical measurement with spectrophotometer. This finding suggests that besides thermal effects, microwave-based food treatment can alter product properties in other ways as well.
Resumo:
Substantial collective flow is observed in collisions between lead nuclei at Large Hadron Collider (LHC) as evidenced by the azimuthal correlations in the transverse momentum distributions of the produced particles. Our calculations indicate that the global v1-flow, which at RHIC peaked at negative rapidities (named third flow component or antiflow), now at LHC is going to turn toward forward rapidities (to the same side and direction as the projectile residue). Potentially this can provide a sensitive barometer to estimate the pressure and transport properties of the quark-gluon plasma. Our calculations also take into account the initial state center-of-mass rapidity fluctuations, and demonstrate that these are crucial for v1 simulations. In order to better study the transverse momentum flow dependence we suggest a new"symmetrized" vS1(pt) function, and we also propose a new method to disentangle global v1 flow from the contribution generated by the random fluctuations in the initial state. This will enhance the possibilities of studying the collective Global v1 flow both at the STAR Beam Energy Scan program and at LHC.