24 resultados para Evaluation of the education system


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Obesity may have an impact on key aspects of health-related quality of life (HRQOL). In this context, the Impact of Weight Quality of Life (IWQOL) questionnaire was the first scale designed to assess HRQOL. The aim of the present study was twofold: to assess HRQOL in a sample of Spanish patients awaiting bariatric surgery and to determine the psychometric properties of the IWQOL-Lite and its sensitivity to detect differences in HRQOL across groups. Methods Participants were 109 obese adult patients (BMI¿ 35 kg/m2) from Barcelona, to whom the following measurement instruments were applied: IWQOL-Lite, Depression Anxiety Stress Scales, Brief Symptom Inventory, and self-perception items. Results Descriptive data regarding the IWQOL-Lite scores obtained by these patients are reported. Principal components analysis revealed a five-factor model accounting for 72.05% of the total variance, with factor loadings being adequate for all items. Corrected itemtotal correlations were acceptable for all items. Cronbach"s alpha coefficients were excellent both for the subscales (0.880.93) and the total scale (0.95). The relationship between the IWQOLLite and other variables supports the construct validity of the scale. Finally, sensitivity analysis revealed large effect sizes when comparing scores obtained by extreme BMI groups. Conclusions This is the first study to report the application of the IWQOL-Lite to a sample of Spanish patients awaiting bariatric surgery and to confirm that the Spanish version of the instrument has adequate psychometric properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This report aims to analyse how European accounting standards (European System of Accounts ESA-95) are interpreted and applied to the public healthcare sector, from the standpoint of comparative law. Specifically, the study focuses on the application of ESA-95 to healthcare centres in the United Kingdom, France and Germany, with the aim of reaching useful conclusions for the Public Companies and Consortia (EPIC, for their initials in Catalan) in the Catalan Public Healthcare System.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background:In January 2011 Spain modified clean air legislation in force since 2006, removing all existing exceptions applicable to hospitality venues. Although this legal reform was backed by all political parties with parliamentary representation, the government's initiative was contested by the tobacco industry and its allies in the hospitality industry. One of the most voiced arguments against the reform was its potentially disruptive effect on the revenue of hospitality venues. This paper evaluates the impact of this reform on household expenditure at restaurants and bars and cafeterias. Methods and empirical strategy:We use micro-data from the Encuesta de Presupuestos Familiares (EPF) for years 2006 to 2012 to estimate "two part" models where the probability of observing a positive expenditure and, for those who spend, the expected level of expenditure are functions of an array of explanatory variables. We apply a before-after analysis with a wide range of controls for confounding factors and a flexible modeling of time effects.Results:In line with the majority of studies that analyze the effects of smoking bans using objective data, our results suggest that the reform did not cause reductions in households' expenditures on restaurant services or on bars and cafeteria services.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: A study was made to determine the temperature increment at the dental root surface following Er,Cr:YSGG laser irradiation of the root canal. Design. Human canines and incisors previously instrumented to K file number ISO 30 were used. Irradiation was carried out with glass fiber endodontic tips measuring 200 μm in diameter and especially designed for insertion in the root canal. The teeth were irradiated at 1 and 2 W for 30 seconds, without water spraying or air, and applying a continuous circular movement (approximately 2 mm/sec.) in the apico-coronal direction. Results: At the 1 W power setting, the mean temperature increment was 3.84ºC versus 5.01ºC at 2 W. In all cases the difference in mean value obtained after irradiation versus the mean baseline temperature proved statistically significant (p< 0.05). Conclusions: Application of the Er,Cr:YSGG laser gives rise to a statistically significant temperature increment at the external root surface, though this increment is probably clinically irrelevant, since it would appear to damage the tissues (periodontal ligament and alveolar bone) in proximity to the treated tooth

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Third molar extraction is the most frequent procedure in oral surgery. The present study evaluates the indication of third molar extraction as established by the primary care dentist (PCD) and the oral surgeon, and compares the justification for extraction with the principal reason for patient consultation. Patients and method: A descriptive study was made of 319 patients subjected to surgical removal of a third molar in the context of the Master of Oral Surgery and Implantology (Barcelona University Dental School, Barcelona, Spain) between July 2004 and March 2005. The following parameters were evaluated: sex, age, molar, type of impaction, position according to the classifications of Pell and Gregory and of Winter, and the reasons justifying extraction. Results: The lower third molars were the most commonly extracted molars (73.7%). A total of 69.6% of the teeth were covered by soft tissues only. Fifty-six percent of the lower molars corresponded to Pell and Gregory Class IIB, while 42.1% were in the vertical position. The most common reason for patient reference to our Service of Oral Surgery on the part of the PCD was prophylactic removal (51.0% versus 46.1% in the case of the oral surgeon). Discussion and conclusions. Our results show prophylaxis to be the principal indication of third molar extraction, followed by orthodontic reasons. Regarding third molars with associated clinical symptoms or signs, infectious disease-including pericoronitis- was the pathology most often observed by the oral surgeon, followed by caries. This order of frequency was seen to invert in the case of third molars referred for extraction by the PCD. A vertical position predominated among the third molars with associated pathology

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report on the results of the spectral and timing analysis of a BeppoSAX observation of the microquasar system LS 5039/RX J1826.2-1450. The source was found in a low-flux state with Fx(1-10 keV)= 4.7 x 10^{-12} erg cm^{-2} s^{-1}, which represents almost one order of magnitude lower than a previous RXTE observation 2.5 years before. The 0.1--10 keV spectrum is described by an absorbed power-law continuum with photon-number spectral index Gamma=1.8+-0.2 and hydrogen column density of NH=1.0^{+0.4}_{-0.3} x 10^{22} cm^{-2}. According to the orbital parameters of the system the BeppoSAX observation covers the time of an X-ray eclipse should one occur. However, the 1.6-10 keV light curve does not show evidence for such an event, which allows us to give an upper limit to the inclination of the system. The low X-ray flux detected during this observation is interpreted as a decrease in the mass accretion rate onto the compact object due to a decrease in the mass-loss rate from the primary.