28 resultados para Electricity in dentistry.


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To compare the results obtained after oral mucocele resection with the scalpel versus the CO2 laser, based on the complications and recurrences after surgery Patients and Methods: Of the 68 patients we studied who have mucocele, 38 were resected with a scalpel and the remaining 30 with the CO2 laser (5-7 W). Patient sex and age were documented, along with location of the lesion as well as size, symptoms, duration, etiological factors, type of treatment, complications and recurrences after surgical removal. Results: The sample comprised 40 males and 28 females, aged between 6-65 years. The histological diagnosis was extravasation mucocele in 95% of the cases. The most frequent location was the lower lip (73.5%). The mean lesion diameter was 9 mm , and in most cases no evident etiological factor was recorded. The mean duration of the lesion was 4 months. Among the cases of conventional surgical removal of mucocele, recurrence was recorded in 8.8% of the cases, and 13.2% of the patients suffered postoperative complications - the most frequent being the presence of fibrous scars. There were no complications or relapses after a minimum follow-up of 12 months in the cases subjected to CO2 laser treatment. Conclusions: Oral mucocele ablation with the CO2 laser offers more predictable results and fewer complications and recurrences than conventional resection with the scalpel

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: Benign Oral Vascular Lesions (BOVLs) are a group of vascular diseases characterized by congenital, inflammatory or neoplastic vascular dilations clinically evidenced as more or less wide masses of commonly dark bluish color. If traumatized BOVLs are characterized by a great risk of hemorrhage and their treatment usually requires great caution to prevent massive bleeding. In the last decades lasers have dramatically changed the way of treatment of BOVLs permitting the application of even peculiar techniques that gave interesting advantages in their management reducing hemorrhage risks. The aim of this study was to evaluate the capabilities and disadvantages of three laser assisted techniques in the management of BOVLs. Study design: In this study 13 BOVLs were treated by three different laser techniques: the traditional excisional biopsy (EB), and two less invasive techniques, the transmucosal thermocoagulation (TMT) and the intralesional photocoagulation (ILP). Two different laser devices were adopted in the study: a KTP laser (DEKA, Florence, Italy, 532nm) and a GaAlAs laser (Laser Innovation, Castelgandolfo, Italy, 808nm) selected since their great effectiveness on hemoglobin. Results: In each case, lasers permitted safe treatments of BOVLs without hemorrhages, both during the intervention and in the post-operative period. The minimally invasive techniques (TMT and ILP) permitted even the safe resolution of big lesions without tissue loss. Conclusions: Laser devices confirm to be the gold standard in BOVLs treatment, permitting even the introduction of minimal invasive surgery principles and reducing the risks of hemorrhage typical of these neoplasms. As usual in laser surgery, it is necessary a clear knowledge of the devices and of the laser-tissue interaction to optimize the results reducing risks and disadvantages

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: To compare upper lip frenulum reinsertion, bleeding, surgical time and surgical wound healing in frenectomies performed with the CO2 laser versus the Er, Cr:YSGG laser. Study design: A prospective study was carried out on 50 randomized pediatric patients who underwent rhomboidal resection of the upper lip frenulum with either the CO2 laser or the Er,Cr:YSGG laser. Twenty-five patients were assigned to each laser system. All patients were examined at 7, 14, 21 days and 4 months after the operation in order to assess the surgical wound healing. Results: Insertion of the frenulum, which was preoperatively located between the upper central incisors, migrated to the mucogingival junction as a result of using both laser systems in all patients. Only two patients required a single dose of 650 mg of paracetamol, one of either study group. CO2 laser registered improved intraoperative bleeding control results and shorter surgical times. On the other hand, the Er,Cr:YSGG laser achieved faster healing. Conclusions: Upper lip laser frenectomy is a simple technique that results in minimum or no postoperative swelling or pain, and which involves upper lip frenulum reinsertion at the mucogingival junction. The CO2 laser offers a bloodless field and shorter surgical times compared with the Er,Cr:YSGG laser. On the other hand, the Er,Cr:YSGG laser achieved faster wound healing.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El láser de Nd:YAG está compuesto por un granate de itrio y aluminio, contaminado por neodimio. Emite a una longitud de onda de 1064 nm, en el infrarrojo cercano. A diferencia de otros láseres, el láser de Nd:YAG, puede transmitirse a través de fibra óptica, lo cual permite una fácil aplicación de este tipo de energía en espacios anatómicos bucodentarios de difícil acceso. Este hecho, asociado al potente efecto bactericida que produce esta longitud de onda, lo convierten en una herramienta ideal en los tratamientos endodóncicos y periodontales, en los que puede mejorar los resultados obtenidos con las técnicas convencionales. También se utiliza en ciertos tratamientos de Cirugía Bucal, principalmente para las exéresis de lesiones de tejidos blandos.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: The aim of this in vitro experimental study was to perform histological evaluation of the thermal effect produced on soft tissue irradiated with CO2, Er,Cr:YSGG or diode lasers. Study design: Porcine oral mucosa samples were irradiated with Er,Cr:YSGG laser at 1 W with and without water / air spray, at 2 W with and without water / air spray, and at 4 W with water / air spray, with CO2 laser at 1 W, 2 W, 10 W, 20 W continuous mode and 20 W pulsed mode and diode laser at 2W, 5W, and 10W pulsed mode. The thermal effect was evaluated measuring the width of damaged tissue adjacent to the incision, stained positively for hyalinized tissue with Hematoxylin-Eosin and Masson Trichrome stains. Besides, histological changes in the irradiated tissue were described using subjective grading scales. Results: The evaluated lasers developed a wide range of thermal damage with significant differences between groups. The samples with lowest thermal effect were those irradiated with Er,Cr:YSGG laser using water / air spray, followed by CO2 and diode lasers. Conclusions: Emission parameters of each laser system may influence the thermal damage inflicted on the soft tissue, however, the wave length of each laser determines the absorption rate characteristics of every tissue and the thermal effect

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To compare the anesthetic action of 0.5% bupivacaine in relation to 4% articaine, both with 1:200,000 epinephrine, in the surgical removal of lower third molars. As a secondary objective hemodynamic changes using both anesthetics were analyzed. Study Design: Triple-blind crossover randomized clinical trial. Eighteen patients underwent bilateral removal of impacted lower third molars using 0.5% bupivacaine or 4% articaine in two different appointments. Preoperative, intraoperative and postoperative variables were recorded. Differences were assessed with McNemar tests and repeated measures ANOVA tests. Results: Both solutions exhibited similar latency times and intraoperative efficacy. Statistical significant lower pain levels were observed with bupivacaine between the fifth (p=0.011) and the ninth (p=0.007) postoperative hours. Bupivacaine provided significantly longer lasting soft tissue anesthesia (p<0.05). Systolic blood pressure and heart rate values were significantly higher with articaine. Conclusions: Bupivacaine could be a valid alternative to articaine especially due to its early postoperative pain prevention ability.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: An evaluation and comparison is made of the thermal increment at different implant surfaces during irradiation with CO2 and ErCr:YSGG lasers. Study design: Five threaded and impacted implants with four types of surfaces were inserted in an adult pig rib: two implants with a hydroxyapatite surface (HA)(impacted and threaded, respectively), a machined titanium surface implant (TI mach), a titanium plasma spray surface implant (TPS), and a sandblasted, acid-etched surface implant (SBAE). A 0.5-mm diameter bone defect was made in the implant apical zone, and a type-K thermocouple (Termopar)® was placed in contact with the implant. The implants were irradiated in the coronal zone of each implant with a CO2 (4 W continuous mode) and an ErCr:YSGG laser (1.5 W, pulsed mode) first without and then with refrigeration. The temperature variations at the implant apical surface were recorded. Results: An apical temperature increase was recorded in all cases during CO2 and ErCr:YSGG laser irradiation without refrigeration. However, when the ErCr:YSGG was used with a water spray, a decrease in temperature was observed in all implants. The acid-etched and sandblasted surfaces were those most affected by the thermal changes. Conclusions: The ErCr:YSGG laser with a water spray applied to the sealing cap or coronal zone of the implants does not generate thermal increments in the apical surface capable of adversely affecting osseointegration and the integrity of the peri-implant bone tissue

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: To compare the clinical anesthetic efficacy of 0.5% bupivacaine and 4% articaine (both with 1:200.000 adrenaline) for anterior maxillary infiltration in healthy volunteers. Material and methods: A triple-blind split-mouth randomized clinical trial was carried out in 20 volunteers. A supraperiosteal buccal injection of 0.9 ml of either solution at the apex of the lateral incisor was done in 2 appointments separated 2 weeks apart. The following outcome variables were measured: latency time, anesthetic efficacy (dental pulp, keratinized gingiva, alveolar mucosa and upper lip mucosa and tissue) and the duration of anesthetic effect. Hemodynamic parameters were monitored during the procedure. Results: Latency time recorded was similar for both anesthetic solutions (p>0.05). No statistically significant differences were found in terms of anesthetic efficacy for dental pulp, keratinized gingiva or alveolar mucosa. Articaine had a significant higher proportion of successful anesthesia at 10 minutes after infiltration in lip mucosa and lip skin (p=0.039). The duration of anesthesia was 336 minutes for bupivacaine and 167 minutes for articaine. (p<0.001). No significant hemodynamic alterations were noted during the procedure. Conclusions: Articaine and bupivacaine exhibited similar anesthetic efficacy for maxillary infiltrations. The duration of anesthesia was longer with the bupivacaine solution, but lip anesthesia was better with articaine

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objetivos: Este trabajo pretende, en base a nuestra experiencia, valorar y discutir las indicaciones, ventajas e inconvenientes de la exéresis de los épulis de la cavidad bucal con el láser de dióxido de carbono (CO2) respecto al láser de Erbio:YAG (Er:YAG), el láser de diodo y el bisturí frío. Material y método: Se ha realizado un estudio retrospectivo de un grupo de 120 pacientes en los que se extirparon 128 épulis con el láser de CO2, láser de Er:YAG, láser de diodo y bisturí frío. Se realizaron controles postoperatorios a los 7, 15 y 30 días para comprobar la cicatrización y la evolución de la herida y a los 3, 6 y 12 meses verificando si se había producido o no la recidiva de la lesión. Resultados: Según las características clínicas y etiopatogénicas de las lesiones extirpadas, se han formado dos grupos: las lesiones hiperplásicas gingivales (77 casos) y los épulis fisurados (51 casos). La localización más frecuente de las hiperplasias gingivales fue la mandíbula (51.9%). Se encontró que la hiperplasia fibrosa fue el diagnóstico histopatológico más frecuente con 49 casos (63.6%). El porcentaje de recidiva tras su extirpación fue del 9,1%, de los cuales 5 casos eran hiperplasias fibrosas. Sólo hubo un caso de lesión maligna que fue diagnosticada de carcinoma de células escamosas infiltrante. Por otro lado, de los 51 épulis fisurados tratados, el 58.8% se encontraban en el maxilar superior. Éstos fueron diagnosticados histológicamente como hiperplasias fibrosas, recidivando en el 19.6% de los casos. Conclusiones: Aunque las diferentes técnicas quirúrgicas utilizadas en la extirpación del épulis de la cavidad bucal son correctas, en nuestra opinión, el láser de CO2 es el tratamiento de elección, ya que ofrece ventajas tanto intra como postoperatorias. Por otro lado, es indispensable analizar histopatológicamente toda lesión de la cavidad bucal para establecer un diagnóstico de certeza

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objetivos: Este trabajo pretende demostrar que se pueden realizar la mayoría de las intervenciones quirúrgicas de la cavidad bucal en la población pediátrica en un medio ambulatorio, así como valorar y mostrar la actividad realizada en el Máster de Cirugía e Implantología Bucal de la Facultad de Odontología de la Universidad de Barcelona durante el año 2000. Diseño del estudio: Para la realización de este trabajo se ha contabilizado la actividad quirúrgica de las unidades de cirugía bucal y cirugía con láser en la población pediátrica en el Máster de Cirugía e Implantología Bucal de la Universidad de Barcelona. Resultados: De las 3187 intervenciones quirúrgicas realizadas en nuestro servicio, 489 fueron en pacientes menores de 18 años. La exodoncia quirúrgica de terceros molares inferiores fue la más frecuente (55'6%), seguida de otras extracciones dentarias (33'6%), quirúrgicas o no, y del resto de intervenciones (10'6%) que incluyeron: fenestraciones de caninos u otros dientes incluidos, exéresis de frenillos, de mucoceles y reubicaciones dentarias. Se presentaron complicaciones tras la extracción quirúrgica de los terceros molares en un 15'93% de los casos, siendo las más frecuentes el dolor (4'35%) y la tumefacción (4'35%), signos propios de la inflamación postoperatoria. Conclusiones: Nuestra experiencia muestra que la cirugía bucal ambulatoria puede practicarse de forma segura en la población pediátrica siempre y cuando se disponga de los medios y del personal sanitario adecuados

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We study the outcomes of experimental multi-unit uniform and discriminatory auctions with demand uncertainty. Our study is motivated by the ongoing debate about market design in the electricity industry. Our main aim is to compare the effect of asymmetric demand-information between sellers on the performance of the two auction institutions. In our baseline conditions all sellers have the same information, whereas in our treatment conditions some sellers have better information than others. In both information conditions we find that average transaction prices and price volatility are not significantly different under the two auction institutions. However, when there is asymmetric information among sellers the discriminatory auction is significantly less efficient. These results are not in line with the typical arguments made in favor of discriminatory pricing in electricity industries; namely, lower consumer prices and less price volatility. Moreover, our results provide some indication that discriminatory auctions reduce technical efficiency relative to uniform auctions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper we check whether generator's bid behavior at the Spanish whosale electricity market is consistent with the hypothesis of profit maximization on their residual demands. Using OMEL data, we find the arc-elacticity of the residual demand around the system marginal price. The results suggest thet the larger firms are not actually profit-msximization. We argue how the regulatory environment may drive these results. Finally, we repeat the analysis for the first session of the intra-day market where presumably firms may not have the same incentives as in the day-ahead market.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

És àmpliament conegut que l'europeïtzació ha guanyat molt terreny en els estudis europeus. Des de finals de la dècada de 1990, ha gaudit d'una important expansió per tal d'avaluar l'eficàcia de les polítiques a escala europea en l'àmbit intern. En aquest procés la política energètica ha jugat un paper molt paradoxal, sent persistentment exclosos de l'agenda de recerca de la europeïtzació, encara que la seva creixent importància en l'elaboració de polítiques comunitàries. No obstant això, la realitat és que, tot i haver estat reconegut recentment com una àrea de la UE amb l'aplicació del Tractat de Lisboa, també ha estat influenciat, directament o indirectament, pels efectes de l'europeïtzació. Com a resultat d'això, la política energètica ha estat considerat com un "cas especial" de l'europeïtzació, portant fins al moment per a la construcció d'un sector caracteritzat la política energètica europea. En aquest context, el present treball pretén explicar l'europeïtzació de les polítiques energètiques nacionals en l'elaboració de l'actuació de la UE per mitjà de la seva competència ambiental. Més explícitament, aquesta investigació tracta de la naturalesa de la reglamentació comunitària en matèria d'energia renovable com un mecanisme d'europeïtzació amb especial èmfasi en el seu impacte a Espanya. Aquest treball sosté que (1) la lluita europea contra el canvi climàtic s'ha obert un camí per a la participació de la UE en matèria de política energètica, i que (2) encara que limitat aquest procés està produint alguns canvis en les polítiques energètiques nacionals. Universitat