22 resultados para EUSTACHIAN TUBE


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Despite the widespread use of interferon-gamma release assays (IGRAs), their role in diagnosing tuberculosis and targeting preventive therapy in HIV-infected patients remains unclear. We conducted a comprehensive systematic review to contribute to the evidence-based practice in HIV-infected people. Methodology/Principal Findings: We searched MEDLINE, Cochrane, and Biomedicine databases to identify articles published between January 2005 and July 2011 that assessed QuantiFERON H -TB Gold In-Tube (QFT-GIT) and T-SPOT H .TB (T-SPOT.TB) in HIV-infected adults. We assessed their accuracy for the diagnosis of tuberculosis and incident active tuberculosis, and the proportion of indeterminate results. The search identified 38 evaluable studies covering a total of 6514 HIV-infected participants. The pooled sensitivity and specificity for tuberculosis were 61% and 72% for QFT-GIT, and 65% and 70% for T-SPOT.TB. The cumulative incidence of subsequent active tuberculosis was 8.3% for QFT-GIT and 10% for T-SPOT.TB in patients tested positive (one study each), and 0% for QFT-GIT (two studies) and T-SPOT.TB (one study) respectively in those tested negative. Pooled indeterminate rates were 8.2% for QFT-GIT and 5.9% for T-SPOT.TB. Rates were higher in high burden settings (12.0% for QFT-GIT and 7.7% for T-SPOT.TB) than in low-intermediate burden settings (3.9% for QFT-GIT and 4.3% for T-SPOT.TB). They were also higher in patients with CD4 + T-cell count, 200 (11.6% for QFT-GIT and 11.4% for T-SPOT.TB) than in those with CD4 + T-cell count $ 200 (3.1% for QFT-GIT and 7.9% for T-SPOT.TB). Conclusions/Significance: IGRAs have suboptimal accuracy for confirming or ruling out active tuberculosis disease in HIV-infected adults. While their predictive value for incident active tuberculosis is modest, a negative QFT-GIT implies a very low short- to medium-term risk. Identifying the factors associated with indeterminate results will help to optimize the use of IGRAs in clinical practice, particularly in resource-limited countries with a high prevalence of HIV-coinfection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In vertebrates, early brain development takes place at the expanded anterior end of the neural tube. After closure of the anterior neuropore, the brain wall forms a physiologically sealed cavity that encloses embryonic cerebrospinal fluid (E-CSF), a complex and protein-rich fluid that is initially composed of trapped amniotic fluid. E-CSF has several crucial roles in brain anlagen development. Recently, we reported the presence of transient blood-CSF barrier located in the brain stem lateral to the ventral midline, at the mesencephalon and prosencephalon level, in chick and rat embryos by transporting proteins, water, ions and glucose in a selective manner via transcellular routes. To test the actual relevance of the control of E-CSF composition and homeostasis on early brain development by this embryonic blood-CSF barrier, we block the activity of this barrier by treating the embryos with 6-aminonicotinamide gliotoxin (6-AN). We demonstrate that 6-AN treatment in chick embryos blocks protein transport across the embryonic blood-CSF barrier, and that the disruption of the barrier properties is due to the cease transcellular caveolae transport, as detected by CAV-1 expression cease. We also show that the lack of protein transport across the embryonic blood-CSF barrier influences neuroepithelial cell survival, proliferation and neurogenesis, as monitored by neurepithelial progenitor cells survival, proliferation and neurogenesis. The blockage of embryonic blood-CSF transport also disrupts water influx to the E-CSF, as revealed by an abnormal increase in brain anlagen volume. These experiments contribute to delineate the actual extent of this blood-CSF embryonic barrier controlling E-CSF composition and homeostasis and the actual important of this control for early brain development, as well as to elucidate the mechanism by which proteins and water are transported thought transcellular routes across the neuroectoderm, reinforcing the crucial role of E-CSF for brain development.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In vertebrates, early brain development takes place at the expanded anterior end of the neural tube, which is filled with embryonic cerebrospinal fluid (E-CSF). We have recently identified a transient blood-CSF barrier that forms between embryonic days E3 and E4 in chick embryos and that is responsible for the transport of proteins and control of E-CSF homeostasis, including osmolarity. Here we examined the presence of glucose transporter GLUT-1 as well the presence of caveolae-structural protein Caveolin1 (CAV-1) in the embryonic blood-CSF barrier which may be involved in the transport of glucose and of proteins, water and ions respectively across the neuroectoderm. In this paper we demonstrate the presence of GLUT-1 and CAV-1 in endothelial cells of blood vessels as well as in adjacent neuroectodermal cells, located in the embryonic blood-CSF barrier. In blood vessels, these proteins were detected as early as E4 in chick embryos and E12.7 in rat embryos, i.e. the point at which the embryonic blood-CSF barrier acquires this function. In the neuroectoderm of the embryonic blood-CSF barrier, GLUT-1 was also detected at E4 and E12.7 respectively, and CAV-1 was detected shortly thereafter in both experimental models. These experiments contribute to delineating the extent to which the blood-CSF embryonic barrier controls E-CSF composition and homeostasis during early stages of brain development in avians and mammals. Our results suggest the regulation of glucose transport to the E-CSF by means of GLUT-1 and also suggest a mechanism by which proteins are transported via transcellular routes across the neuroectoderm, thus reinforcing the crucial role of E-CSF in brain development.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Corrosion reduces the lifetime of municipal solid waste incineration (MSWI) superheater tubes more than any other cause. It can be minimized by the careful selection of those materials that are most resistant to corrosion under operating conditions. Since thousands of different materials are already known and many more are developed every year, here the selection methodology developed by Prof. Ashby of the University of Cambridge was used to evaluate the performance of different materials to be used as MSWI superheater tubes. The proposed materials can operate at steam pressures and temperatures over 40 bars and 400ºC, respectively. Two case studies are presented: one makes a balanced selection between mechanical properties and cost per thermal unit; and the other focuses on increasing tube lifetime. The balanced selection showed that AISI 410 martensitic stainless steel (wrought, hard tempered) is the best candidate with a good combination of corrosion resistance, a relatively low price (0.83-0.92 e/kg) and a good thermal conductivity (23-27 W/m K). Meanwhile, Nitronic 50/XM-19 stainless steel is the most promising candidate for longterm selection, as it presents high corrosion resistance with a relatively low price (4.86-5.14 e/kg) compared to Ni-alloys.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Catalunya és un dels territoris on hi ha hagut més auge del sector de la cervesa artesana, i són molt nombroses les microcerveseries i les botigues especialitzades on es poden trobar els recursos materials necessaris, a més de ser centres difusió de coneixements relacionats. Així, doncs, aquest projecte està emmarcat en un context que permet el desenvolupament de tècniques d’elaboració de cervesa artesana. Aquest projecte es basa en la construcció d’un equip amb materials reutilitzats i amb un pressupost limitat que permet reproduir a petita escala els processos d’elaboració que es duen a terme en les microcerveseries artesanes actuals. El projecte s’ha assentat sobre la comprensió dels fonaments teòrics i pràctics del procés d’elaboració de cervesa, i amb l’experiència inicial d’elaboració de cervesa amb un equip bàsic de tipus homebrewer. Per minimintzar costos els tancs s’han construït a partir de barrils de cervesa i les parts sobrants s’han aprofitat per a altres elements. S’han emprat elements quotidians com una olla a pressió i s’ha construït un sistema regulador de pressió (per al tanc de fermentació cilindrocònic isobàric construït) en lloc d’adquirir-lo. S’ha posat l’èmfasi en minimitzar la necessitat de manipulació manual durant l’elaboració. Per tant, s’han instal·lat els components de l’equip formant un circuit tancat amb sistema de bombeig, i s’ha incorporat un sistema que permet el control i la lectura de les temperatures de cada procés. Altres elements són el sistema de filtres amb mecanisme de tub en forma d’ela (que permet l’extracció del most dels tanc de maceració i de cocció d’una manera efectiva i sense necessitat de manipulació) i el sistema de dutxa (que permet automatitzar el procés de rentat i filtrat). Un element que distingeix aquest equip d’altres equips emprats en algunes microcerveseries artesanes és el tanc de fermentació cilindrocònic isobàric amb vàlvula controladora de pressió, que permet prescindir de la doble fermentació en ampolla, ja que permet aprofitar el gas carbònic produït durant la fermentació per la carbonatació de la cervesa. Es pot concloure que gràcies a les seves característiques, l’equip permet realitzar successives elaboracions obtenint el mateix producte amb les mateixes característiques organolèptiques, principalement gràcies a la cambra de fermentació, que permet realitzar les etapes de fermentació, maduració i clarificació controlant la temperatura desitjada; al tanc de maceració amb aïllament, que permet realitzar el procés a temperatura constant sense pèrdues tèrmiques i al sistema de control de temperatura de totes les etapes. L’únic inconvenient és que, degut a la manca pressupostària, ha estat impossible l’adquisició d’un sistema d’embotellament isobàric que permeti realitzar l’embotellament sense pèrdues del gas carbònic. Per tant, el producte final pot embotellar-se amb una lleugera pèrdua de gas o es pot emmagatzemar en el mateix fermentador cilindrocònic per al seu consum directe, a l’estil d’alguns brewpubs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the performance of the Tuberculin Skin Test (TST) and Quantiferon-TB Gold in-Tube (QFT) and the possible association of factors which may modify their results in young children (0-6 years) with recent contact with an index tuberculosis case. Materials and Methods: A cross-sectional study including 135 children was conducted in Manaus, Amazonas-Brazil. The TST and QFT were performed and the tests results were analyzed in relation to the personal characteristics of the children studied and their relationship with the index case. Results: The rates of positivity were 34.8% (TST) and 26.7% (QFT), with 14.1% of indeterminations by the QFT. Concordance between tests was fair (Kappa = 0.35 P<0.001). Both the TST and QFT were associated with the intensity of exposure (Linear OR = 1.286, P = 0.005; Linear OR = 1.161, P = 0.035 respectively) with only the TST being associated with the time of exposure (Linear OR = 1.149, P = 0.009). The presence of intestinal helminths in the TST+ group was associated with negative QFT results (OR = 0.064, P = 0.049). In the TST- group lower levels of ferritin were associated with QFT+ results (Linear OR = 0.956, P = 0.036). Conclusions: Concordance between the TST and QFT was lower than expected. The factors associated with the discordant results were intestinal helminths, ferritin levels and exposure time to the index tuberculosis case. In TST+ group, helminths were associated with negative QFT results suggesting impaired cell-mediated immunity. The TST-&QFT+ group had a shorter exposure time and lower ferritin levels, suggesting that QFT is faster and ferritin may be a potential biomarker of early stages of tuberculosis infection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have analyzed the shot noise of electron emission under strong applied electric fields within the Landauer-Bttiker scheme. In contrast to the previous studies of vacuum-tube emitters, we show that in new generation electron emitters, scaled down to the nanometer dimensions, shot noise much smaller than the Schottky noise is observable. Carbon nanotube field emitters are among possible candidates to observe the effect of shot-noise suppression caused by quantum partitioning.