20 resultados para Determination method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The two independent components of the gyration tensor of quartz, g11 and g33, have been spectroscopically measured using a transmission two-modulator generalized ellipsometer. The method is used to determine the optical activity in crystals in directions other than the optic axis, where the linear birefringence is much larger than the optical activity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Our aim in this study was to determine the concentration of salivary glucose in healthy individuals and to compare it with the capillary glycemia. Study design: Samples of unstimulated whole saliva were collected from 63 non-diabetic patients. The concentration of salivary glucose and capillary blood was measured in all of the patients. The salivary glucose was determined by enzymatic method and spectrophotometry. The data was then analyzed using the Spearman correlation test, considering values of p<0.05 to be significant. Results: The whole sample consisted of 47.6% males and 52.4% women, with an average age of 37.5±15.7 years old. The average rates of unstimulated salivary flow were 0.41±0.21 ml/min among males and 0.31±0.15 ml/min among females. No significant difference was found based on these results (p=0.078). The average blood glucose among the males studied was 100.05±13.51 mg/dL, and among females, it was 99.5±13.9 mg/dL. The average salivary glucose for the whole sample was 5.97±1.87 mg/dL, with 5.91±2.19 mg/dL among males and 5.97±1.56 mg/dL among females, respectively, without presenting any significant differences (p=0.908). The concentration of salivary glucose did not present any statistically significant correlation with the capillary glycemia (p=0.732). Conclusions: The results suggest that the concentration of salivary glucose is not dependent on capillary glycemia and that the concentration of salivary glucose does not present significant differences between the measurements for males and females.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Experimental evidences demonstrate that vegetable derived extracts inhibit cholesterol absorption in the gastrointestinal tract. To further explore the mechanisms behind, we modeled duodenal contents with several vegetable extracts. Results: By employing a widely used cholesterol quantification method based on a cholesterol oxidase-peroxidase coupled reaction we analyzed the effects on cholesterol partition. Evidenced interferences were analyzed by studying specific and unspecific inhibitors of cholesterol oxidase-peroxidase coupled reaction. Cholesterol was also quantified by LC/MS. We found a significant interference of diverse (cocoa and tea-derived) extracts over this method. The interference was strongly dependent on model matrix: while as in phosphate buffered saline, the development of unspecific fluorescence was inhibitable by catalase (but not by heat denaturation), suggesting vegetable extract derived H2O2 production, in bile-containing model systems, this interference also comprised cholesterol-oxidase inhibition. Several strategies, such as cholesterol standard addition and use of suitable blanks containing vegetable extracts were tested. When those failed, the use of a mass-spectrometry based chromatographic assay allowed quantification of cholesterol in models of duodenal contents in the presence of vegetable extracts. Conclusions: We propose that the use of cholesterol-oxidase and/or peroxidase based systems for cholesterol analyses in foodstuffs should be accurately monitored, as important interferences in all the components of the enzymatic chain were evident. The use of adequate controls, standard addition and finally, chromatographic analyses solve these issues.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The complexing capacity of synthetic (0.011 M tartrate in 13.5% ethanol) and real wine (Raimat Abadia) in titrations with added total Zn concentrations up to 0.03 M has been determined following the free Zn concentrations with AGNES (absence of gradients and Nernstian equilibrium stripping) technique. A correction to find the preconcentration factor or gain (Y1) really applied at each one of the ionic strengths reached due to Zn additions along the titration has been applied. The standard implementation of AGNES to real wine led to the observation of two anomalous behaviors: (a) an increasingly negative current in the deposition stage (labeled as “HER” effect) and (b) a minimum in the currents of the stripping stage plot (labeled as the “dip” effect). A practical strategy to apply AGNES avoiding the dip effect has been developed to quantify properly free Zn concentrations. The van den Berg–Ružic–Lee linearization method (assuming the existence of just 1:1 complexes) has been adapted to consider the dilution effect and the ionic strength changes. Aggregated stability constants and total ligand concentrations have been calculated from synthetic and wine titration data. The found complexing capacity in the studied wine (cT,L = 0.0179 ± 0.0007 M) indicates the contribution of ligands other than tartrate (which is confirmed to be the main one).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Needle trap devices (NTDs) are a relatively new and promising tool for headspace (HS) analysis. In this study, a dynamic HS sampling procedure is evaluated for the determination of volatile organic compounds (VOCs) in whole blood samples. A full factorial design was used to evaluate the influence of the number of cycles and incubation time and it is demonstrated that the controlling factor in the process is the number of cycles. A mathematical model can be used to determine the most appropriate number of cycles required to adsorb a prefixed amount of VOCs present in the HS phase whenever quantitative adsorption is reached in each cycle. Matrix effect is of great importance when complex biological samples, such as blood, are analyzed. The evaluation of the salting out effect showed a significant improvement in the volatilization of VOCs to the HS in this type of matrices. Moreover, a 1:4 (blood:water) dilution is required to obtain quantitative recoveries of the target analytes when external calibration is used. The method developed gives detection limits in the 0.020–0.080 μg L−1 range (0.1–0.4 μg L−1 range for undiluted blood samples) with appropriate repeatability values (RSD < 15% at high level and <23% at LOQ level). Figure of merits of the method can be improved by using a smaller phase ratio (i.e., an increase in the blood volume and a decrease in the HS volume), which lead to lower detection limits, better repeatability values and greater sensibility. Twenty-eight blood samples have been evaluated with the proposed method and the results agree with those indicated in other studies. Benzene was the only target compound that gave significant differences between blood levels detected in volunteer non-smokers and smokers