190 resultados para Juan María Songel
Resumo:
A capillary microtrap thermal desorption module is developed for near real-time analysis of volatile organic compounds (VOCs) at sub-ppbv levels in air samples. The device allows the direct injection of the thermally desorbed VOCs into a chromatographic column. It does not use a second cryotrap to focalize the adsorbed compounds before entering the separation column so reducing the formation of artifacts. The connection of the microtrap to a GC–MS allows the quantitative determination of VOCs in less than 40 min with detection limits of between 5 and 10 pptv (25 °C and 760 mmHg), which correspond to 19–43 ng m−3, using sampling volumes of 775 cm3. The microtrap is applied to the analysis of environmental air contamination in different laboratories of our faculty. The results obtained indicate that most volatile compounds are easily diffused through the air and that they also may contaminate the surrounding areas when the habitual safety precautions (e.g., working under fume hoods) are used during the manipulation of solvents. The application of the microtrap to the analysis of VOCs in breath samples suggest that 2,5-dimethylfuran may be a strong indicator of a person's smoking status
Resumo:
Different compounds have been reported as biomarkers of a smoking habit, but, to date, there is no appropriate biomarker for tobacco-related exposure because the proposed chemicals seem to be nonspecific or they are only appropriate for short-term exposure. Moreover, conventional sampling methodologies require an invasive method because blood or urine samples are required. The use of a microtrap system coupled to gas chromatography–mass spectrometry analysis has been found to be very effective for the noninvasive analysis of volatile organic compounds in breath samples. The levels of benzene, 2,5-dimethylfuran, toluene, o-xylene, and m- p-xylene have been analyzed in breath samples obtained from 204 volunteers (100 smokers, 104 nonsmokers; 147 females, 57 males; ages 16 to 53 years). 2,5-Dimethylfuran was always below the limit of detection (0.005 ppbv) in the nonsmoker population and always detected in smokers independently of the smoking habits. Benzene was only an effective biomarker for medium and heavy smokers, and its level was affected by smoking habits. Regarding the levels of xylenes and toluene, they were only different in heavy smokers and after short-term exposure. The results obtained suggest that 2,5-dimethylfuran is a specific breath biomarker of smoking status independently of the smoking habits (e.g., short- and long-term exposure, light and heavy consumption), and so this compound might be useful as a biomarker of smoking exposure
Resumo:
Needle trap devices (NTDs) are a relatively new and promising tool for headspace (HS) analysis. In this study, a dynamic HS sampling procedure is evaluated for the determination of volatile organic compounds (VOCs) in whole blood samples. A full factorial design was used to evaluate the influence of the number of cycles and incubation time and it is demonstrated that the controlling factor in the process is the number of cycles. A mathematical model can be used to determine the most appropriate number of cycles required to adsorb a prefixed amount of VOCs present in the HS phase whenever quantitative adsorption is reached in each cycle. Matrix effect is of great importance when complex biological samples, such as blood, are analyzed. The evaluation of the salting out effect showed a significant improvement in the volatilization of VOCs to the HS in this type of matrices. Moreover, a 1:4 (blood:water) dilution is required to obtain quantitative recoveries of the target analytes when external calibration is used. The method developed gives detection limits in the 0.020–0.080 μg L−1 range (0.1–0.4 μg L−1 range for undiluted blood samples) with appropriate repeatability values (RSD < 15% at high level and <23% at LOQ level). Figure of merits of the method can be improved by using a smaller phase ratio (i.e., an increase in the blood volume and a decrease in the HS volume), which lead to lower detection limits, better repeatability values and greater sensibility. Twenty-eight blood samples have been evaluated with the proposed method and the results agree with those indicated in other studies. Benzene was the only target compound that gave significant differences between blood levels detected in volunteer non-smokers and smokers