3 resultados para knowledge source
em Galway Mayo Institute of Technology, Ireland
Resumo:
This study utilised recent developments in forensic aromatic hydrocarbon fingerprint analysis to characterise and identify specific biogenic, pyrogenic and petrogenic contamination. The fingerprinting and data interpretation techniques discussed include the recognition of: The distribution patterns of hydrocarbons (alkylated naphthalene, phenanthrene, dibenzothiophene, fluorene, chrysene and phenol isomers), • Analysis of “source-specific marker” compounds (individual saturated hydrocarbons, including n-alkanes (n-C5 through 0-C40) • Selected benzene, toluene, ethylbenzene and xylene isomers (BTEX), • The recalcitrant isoprenoids; pristane and phytane and • The determination of diagnostic ratios of specific petroleum / non-petroleum constituents, and the application of various statistical and numerical analysis tools. An unknown sample from the Irish Environmental Protection Agency (EPA) for origin characterisation was subjected to analysis by gas chromatography utilising both flame ionisation and mass spectral detection techniques in comparison to known reference materials. The percentage of the individual Polycyclic Aromatic Hydrocarbons (PAIIs) and biomarker concentrations in the unknown sample were normalised to the sum of the analytes and the results were compared with the corresponding results with a range of reference materials. In addition, to the determination of conventional diagnostic PAH and biomarker ratios, a number of “source-specific markers” isomeric PAHs within the same alkylation levels were determined, and their relative abundance ratios were computed in order to definitively identify and differentiate the various sources. Statistical logarithmic star plots were generated from both sets of data to give a pictorial representation of the comparison between the unknown sample and reference products. The study successfully characterised the unknown sample as being contaminated with a “coal tar” and clearly demonstrates the future role of compound ratio analysis (CORAT) in the identification of possible source contaminants.
The appraisal of anaerobic digestion in Ireland to develop improved designs and operational practice
Resumo:
Mesophilic Anaerobic Digestion treating sewage sludge was investigated at five full-scale sewage treatment plants in Ireland. The anaerobic digestion plants are compared and evaluated in terms of design, equipment, operation, monitoring and management. All digesters are cylindrical, gas mixed and heated Continuously Stirred Tank Reactors (CSTR), varying in size from 130m3 to 800m3. Heat exchanger systems heat all digesters. Three plants reported difficulties with the heating systems ranging from blockages to insufficient insulation and design. Exchangers were modified and replaced within one year of operation at two plants. All but one plant had Combined Heat and Power (CHP) systems installed. Parameter monitoring is a problem at all plants mainly due to a lack of staff and knowledge. The plant operators consider pH and temperature the most important parameters to be measured in terms of successful monitoring of an anaerobic digester. The short time taken and the ease at which pH and temperature can be measured may favour these parameters. Three laboratory scale pilot anaerobic digesters were operated using a variety of feeds over at 144-day period. Two of the pilots were unmixed and the third was mechanically mixed. As expected the unmixed reactors removed more COD by retention of solids in the digesters but also produced greater quantities of biogas than the mixed digester, especially when low solids feed such as whey was used. The mixed digester broke down more solids due to the superior contact between the substrate and the biomass. All three reactors showed good performance results for whey and sewage solids. Scum formation occurred giving operational problems for mixed and unmixed reactors when cattle slurry was used as the main feed source. The pilot test was also used to investigate which parameters were the best indicators of process instability. These trials clearly indicated that total Volatile Fatty Acid (VFA) concentrations was the best parameter to show signs of early process imbalance, while methane composition in the biogas was good to indicate possible nutrient deficiencies in the feed and oxygen shocks. pH was found to be a good process parameter only if the wastewater being treated produced low bicarbonate alkalinities during treatment.
Resumo:
Driven by concerns about rising energy costs, security of supply and climate change a new wave of Sustainable Energy Technologies (SET’s) have been embraced by the Irish consumer. Such systems as solar collectors, heat pumps and biomass boilers have become common due to government backed financial incentives and revisions of the building regulations. However, there is a deficit of knowledge and understanding of how these technologies operate and perform under Ireland’s maritime climate. This AQ-WBL project was designed to address both these needs by developing a Data Acquisition (DAQ) system to monitor the performance of such technologies and a web-based learning environment to disseminate performance characteristics and supplementary information about these systems. A DAQ system consisting of 108 sensors was developed as part of Galway-Mayo Institute of Technology’s (GMIT’s) Centre for the Integration of Sustainable EnergyTechnologies (CiSET) in an effort to benchmark the performance of solar thermal collectors and Ground Source Heat Pumps (GSHP’s) under Irish maritime climate, research new methods of integrating these systems within the built environment and raise awareness of SET’s. It has operated reliably for over 2 years and has acquired over 25 million data points. Raising awareness of these SET’s is carried out through the dissemination of the performance data through an online learning environment. A learning environment was created to provide different user groups with a basic understanding of a SET’s with the support of performance data, through a novel 5 step learning process and two examples were developed for the solar thermal collectors and the weather station which can be viewed at http://www.kdp 1 .aquaculture.ie/index.aspx. This online learning environment has been demonstrated to and well received by different groups of GMIT’s undergraduate students and plans have been made to develop it further to support education, awareness, research and regional development.