2 resultados para fast pyrolysis bio-oil components

em Galway Mayo Institute of Technology, Ireland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the effects of biosurfactants and organic matter amendments on the bioremediation of diesel contaminated soil. Two strains of Pseudomonas aeruginosa with the ability to produce biosurfactant were isolated from a water and soil sample in Co. Sligo. The first strain, Isolate A, produced a biosurfactant which contained four rhamnose containing compounds, when grown in proteose peptone glucose ammonium salts medium with glucose as the carbon source. Two of the components were identified as rhamnolipid 1 and 2 whilst the other two components were unidentified. The second strain, Isolate GO, when grown in similar conditions produced a biosurfactant which contained only rhamnolipid 2. The type of aeration system used had a significant effect on the abiotic removal of diesel from soil. Forced aeration at a rate of 120L 02/kg soil/ hour resulted in the greatest removal. Over a 112 day incubation period this type o f aeration resulted in the removal o f 48% o f total hexane extractable material. In relation to bioremediation of the diesel contaminated sandy soil, amending the soil with two inorganic nutrients, KH2PO4 and NÜ4N03, significantly enhanced the removal of diesel, especially the «- alkanes, when compared to an unamended control. The biosurfactant from Isolate A and a biosurfactant produced by Pseudomonas aeruginosa NCIMB 8628 (a known biosurfactant producer), when applied at a concentration of three times their critical micelle concentration, had a neutral effect on the biodégradation o f diesel contaminated sandy soil, even in the presence o f inorganic nutrients. It was deduced that the main reason for this neutral effect was because they were both readily biodegraded by the indigenous microorganisms. The most significant removal of diesel occurred when the soils were amended with two organic materials plus the inorganic nutrients. Amendment of the diesel contaminated soil with spent brewery grain (SBG) removed significantly more diesel than amendment with dried molassed sugar beet pulp (DMSBP). After a 108 day incubation period, amendment of the diesel contaminated soil with DMSBP plus inorganic nutrients and SBG plus inorganic nutrients resulted in 72 and 89% removal of diesel range organics (DRO), in comparison to 41% removal of DRO in an inorganic nutrient amended control. The first order kinetic model described the degradation of the different diesel components with high correlation and was used to calculate Vi lives. The V2 life, of the total «-alkanes in the diesel was reduced from 40 days in the control to 8.5 and 5.1 days in the presence of DMSBP and SBG, respectively. The V2 life o f the unresolved complex mixture (UCM) in the diesel contaminated soil was also significantly reduced in the presence o f the two organics. DMSBP and SBG addition reduced UCM V2 life to 86 and 43 days, respectively, compared to 153 days in the control. The component of diesel whose removal was enhanced the greatest through the organic material amendments was the isoprenoid, pristane, a compound which until recently was thought to be nonbiodegradable and was used as an inert biomarker in oil degradation studies. The V2 life of pristane was reduced from 533 days in the nutrient amended control to 49.5 and 19.5 days in DMSBP and SBG amended soils. These results indicate that the addition o f the DMSBP and SBG to diesel contaminated soil stimulated diesel biodégradation, probably by enhancing the indigenous diesel degrading microbial population to degrade diesel hydrocarbons, whilst the addition o f biosurfactants had no enhanced effect on the bioremediation process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stand alone solar powered refrigeration and water desalination, two of the most popular and sought after applications of solar energy systems, have been selected as the topic of research for the works presented in this thesis. The water desalination system based on evaporation and condensation was found to be the most suitable one to be powered by solar energy. It has been established that highoutput fast-response solar heat collectors used to achieve high rates of evaporation and reliable solar powered cooling system for faster rates of condensation are the most important factors in achieving increased outputs in solar powered desalination systems. Comprehensive reviews of Solar powered cooling/refrigeration and also water desalination techniques have been presented. In view of the fact that the Institute of Technology, Sligo has a well-established long history of research and development in the production of state of the art high-efficiency fast-response evacuated solar heat collectors it was decided to use this know how in the work described in this thesis. For this reason achieving high rates of evaporation was not a problem. It was, therefore, the question of the solar powered refrigeration that was envisaged to be used in the solar powered desalination tofacilitate rapid condensation of the evaporated water that had to be addressed first. The principles of various solar powered refrigeration techniques have also been reviewed. The first step in work on solar powered refrigeration was to successfully modify a conventional refrigerator working on Platen-Munters design to be powered by highoutput fast-response evacuated solar heat collectors. In this work, which was the first ever successful attempt in the field, temperatures as low as —19°C were achieved in the icebox. A new approach in the use of photovoltaic technology to power a conventional domestic refrigerator was also attempted. This was done by modifying a conventional domestic refrigerator to be powered by photovoltaic panels in the most efficient way. In the system developed and successfully tested in this approach, the power demand has been reduced phenomenally and it is possible to achieve 48 hours of cooling power with exposure to just 7 hours of sunshine. The successful development of the first ever multi-cycle intermittent solar powered icemaker is without doubt the most exciting breakthrough in the work described in this thesis. Output of 74.3kg of ice per module with total exposure area of 2.88 m2, or 25.73kg per m2, per day is a major improvement in comparison to about 5-6kg of ice per m2 per day reported for all the single cycle intermittent systems. This system has then become the basis for the development of a new solar powered refrigeration system with even higher output, named the “composite” system described in this thesis. Another major breakthrough associated with the works described in this thesis is the successful development and testing of the high-output water desalination system. This system that uses a combination of the high-output fast-response evacuated solar heat collectors and the multi-cycle icemaker. The system is capable of producing a maximum of 141 litres of distilled water per day per module which has an exposure area of 3.24m2, or a production rate of 43.5 litres per m2 per day. Once again when this result is compared to the reported daily output of 5 litres of desalinated water per m per day the significance of this piece of work becomes apparent. In the presentation of many of the components and systems described in this thesis CAD parametric solid modelling has been used instead of photographs to illustrate them more clearly. The multi-cycle icemaker and the high-output desalination systems are the subject of two patent applications.