3 resultados para Project 2002-035-C : Linking Best Value Procurement Assessment to Outcome Performance Indicators

em Galway Mayo Institute of Technology, Ireland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ireland’s remote position on the tip of Europe ensures that the country is vulnerable to uncertainty of supply. The reliance on conventional sources of electricity has ensured that escalated prices and high carbon emissions have been witnessed whilst opportunities that inherent resources provide, such as the wind, have not been capitalised upon. The intermittent nature of the wind make it difficult to maximise its potential as in many cases the highest wind speeds are highest when demand is low. The West of Ireland’s combination of wind speeds and unique topography makes it suitable for and innovative wind powered pumped storage system, which can essentially regulate the wind generated electricity and integrate further penetration of renewable energy. In addition, its location along the Atlantic Ocean provides further scope for innovation as seawater can be integrated into the system design. The construction of such an unprecedented project in combination with increased interconnectors has the potential to make Ireland a rechargeable battery for Europe. However, such ambitious plans are at the very early stages and are in direct contrast to current events in the Irish energy market. This study focuses on the feasibility of West of Ireland pumped storage systems. Entailed within this is an extensive desk study, a detailed site selection process and a feasibility study of grid connection. To increase opportunities to identify the best possible site, the feasibility study was focused on the Galway and Mayo areas solely.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study analyses the area of construction and demolition waste (C & D W) auditing. The production of C&DW has grown year after year since the Environmental Protection Agency (EPA) first published a report in 1996 which provided data for C&D W quantities for 1995 (EPA, 1996a). The most recent report produced by the EPA is based on data for 2005 (EPA, 2006). This report estimated that the quantity of C&DW produced for that period to be 14 931 486 tonnes. However, this is a ‘data update’ report containing an update on certain waste statistics so any total provided would not be a true reflection of the waste produced for that period. This illustrates that a more construction site-specific form of data is required. The Department of Building and Civil Engineering in the Galway-Mayo Institute of Technology have carried out two recent research projects (Grimes, 2005; Kelly, 2006) in this area, which have produced waste production indicators based on site-specific data. This involved the design and testing of an original auditing tool based on visual characterisation and the application of conversion factors. One of the main recommendations of these studies was to compare this visual characterisation approach with a photogrammetric sorting methodology. This study investigates the application of photogrammetric sorting on a residential construction site in the Galway region. A visual characterisation study is also carried out on the same project to compare the two methodologies and assess the practical application in a construction site environment. Data collected from the waste management contractor on site was also used to provide further evaluation. From this, a set of waste production indicators for new residential construction was produced: □ 50.8 kg/m2 for new residential construction using data provided by the visual characterisation method and the Landfill Levy conversion factors. □ 43 kg/m2 for new residential construction using data provided by the photogrammetric sorting method and the Landfill Levy conversion factors. □ 23.8 kg/m2 for new residential construction using data provided by Waste Management Contractor (WMC). The acquisition of the data from the waste management contractor was a key element for testing of the information produced by the visual characterisation and photogrammetric sorting methods. The actual weight provided by the waste management contractor shows a significant difference between the quantities provided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although the ASP model has been around for over a decade, it has not achieved the expected high level of market uptake. This research project examines the past and present state of ASP adoption and identifies security as a primary factor influencing the uptake of the model. The early chapters of this document examine the ASP model and ASP security in particular. Specifically, the literature and technology review chapter analyses ASP literature, security technologies and best practices with respect to system security in general. Based on this investigation, a prototype to illustrate the range and types of technologies that encompass a security framework was developed and is described in detail. The latter chapters of this document evaluate the practical implementation of system security in an ASP environment. Finally, this document outlines the research outputs, including the conclusions drawn and recommendations with respect to system security in an ASP environment. The primary research output is the recommendation that by following best practices with respect to security, an ASP application can provide the same level of security one would expect from any other n-tier client-server application. In addition, a security evaluation matrix, which could be used to evaluate not only the security of ASP applications but the security of any n-tier application, was developed by the author. This thesis shows that perceptions with regard to fears of inadequate security of ASP solutions and solution data are misguided. Finally, based on the research conducted, the author recommends that ASP solutions should be developed and deployed on tried, tested and trusted infrastructure. Existing Application Programming Interfaces (APIs) should be used where possible and security best practices should be adhered to where feasible.