2 resultados para Graft protection

em Galway Mayo Institute of Technology, Ireland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the project was to determine the extent and quality of the groundwater in Tipperary South Riding with a view to developing a groundwater protection plan which would allow the Local Authority to manage, protect and develop the groundwater as efficiently as possible. The geology of the area varies with topography. The low-lying areas of the county comprise mainly Carboniferous limestones while the elevated regions consist of sandstones and shales of Upper Carboniferous, Devonian and Silurian ages. Deformation of these rocks decreases in magnitude moving northwards over the area; the Southern Synclines having suffered the effects of the Hercynian orogeny and the northern region exhibiting Caledonian orogenic trends. Quaternary (subsoil) deposits are found throughout the area and are of variable thickness and permeability. Till is the most widespread deposit with discontinuous pockets of sand and gravel in various proportions, and some marl, alluvium and peat in places. The principal aquifers of the area are the Kiltorcan sandstone formation and various limestone units within the Carboniferous succession. 50 % of south Tipperary constitutes either regionally or locally important aquifers. Secondary permeabilities created by structural deformation, dolomitisation, karstification and weathering processes create high transmissivities and often have large well yields. Specific baseflow analysis highlighted the complexity of the aquifers and proved that the lower part of the Suir river system is a major groundwater resource region. The hydrochemistry and water quality of the local authority groundwater sources was examined briefly. The majority of south Tipperary is underlain by limestone or Quaternary deposits derived from limestone and, consequently, calcium/magnesium bicarbonate waters predominate. The quality of the groundwater in south Tipperary demonstrates that the main concern originates from the presence of E.coli, and Total coliforms. The primary sources of contamination are from farmyard wastes and septic tanks. The vulnerability of groundwater to diffuse and point sources of pollution has been found to be dependent on the overlying soil, subsoil and the thickness of the unsaturated zone. A conceptual rather than quantitative approach is used and it is found that approximately 60% of south Tipperary is designated as being extremely or highly vulnerable. The groundwater protection plan was devised subsequent to an understanding of the aquifer systems, an assessment of the vulnerability, and a review of the Irish planning system and environmental law. It is recommended that the plan be integrated into the county development plan for legislative purposes. A series of acceptability matrices were devised to restrict potentially polluting activities in vulnerable areas while maintaining a balance between protection of the groundwater resource and the need to site essential developments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abdominal Aortic Aneurysms (AAA) haemorhaging is a life-threatening disease. An aneurysm is a permanent swelling of an artery due to a weakness in its wall. Current surgical repair involves opening the chest or abdomen, gaining temporary vascular control of the aorta and suturing a prosthetic graft to the healthy aorta within the aneurysm itself The outcome of this surgical approach is not perfect, and the quality of life after this repair is impaired by postoperative pain, sexual dysfunction, and a lengthy hospital stay resulting in high health costs. All these negative effects are related to the large incision and extensive tissue dissection. Endovascular grafting is an alternative to the standard surgical method. This treatment is a less invasive method of treating aortic aneurysms. It involves a surgical exposure of the common femoral arteries where the stent graft can be inserted through by an over-the-wire technique. All manipulations are controlled from a remote place by the use of a catheter and this technique avoids the need to directly expose the diseased artery through a large incision or an extensive dissection. The proposed design method outlined in this project is to develop the endovascular approach. The main aim is to design an unitary bifurcated stent graft (1 e- bifurcated graft as a single component) to treat these Abdominal Aortic Aneurysms. This includes the delivery system and deployment mechanism necessary to first accurately position the stent graft across the aneurysm sac and also across the iliac bifurcation, and secondly fix the stent graft in position by using expandable metal stents. Thus, excluding the aneurysm from the circulation and therefore preventing rupture. Miniaturisation is a critical aspect of this design, as the smaller the crimped stent graft the easier to guide through the vascular system to the desired location. Biocompatibility is an important aspect. The preferred materials for this prosthesis are to use Shape Memory Alloys for the stent and a multifilament fabric for the graft. A taper design is applied for the geometry as this gives a favourable flow characteristic and reduced wave reflections. Adequate testing of the stent graft to prove its durability and the ease of the method of deployment is a prerequisite. A bench test facility has being designed and build to replicate the cardiovascular system and the disease in question aortic aneurysms at the iliac bifurcation. The testing here shows the feasibility of the proposed delivery system and the durability of the stent graft across the aneurysm sac. Finally, these endovascular treatments offer the economic advantage of short hospital stays or even treatment as an outpatient, as well as elimination of the need for postoperative intensive care The risk of developing an aneurysm increases with age, that is one of the mam reasons to look for less invasive ways of treating aneurysms. Consequently, there is enormous pressure to develop and use these devices rapidly.