5 resultados para Environmental stressor
em Galway Mayo Institute of Technology, Ireland
Resumo:
All organisations make some contribution to the degradation of the environment through their use of resources and production of waste. Environmental management systems (EMS) standards can provide a tool for companies to systematically reduce their environmental impacts. ISO 14001 was published in 1996. This fitted in with plans of the case study company to take proactive action in this area, even though there was no legislative requirement for them to do so. As EMS implementation was a new area at the time, appropriate methodologies were developed to address different aspects of the implementation, and ISO 14001 was successfully implemented in the company. The results of the primary research included: ♦ Drawing up a methodology for identifying and interpreting the environmental legislation that may have an impact on the organisation and compiling a register of such regulations. ♦ Developing a robust methodology for assessing significant environmental aspects and impacts and applying this to the software company. ♦ Establishing objectives and targets for those aspects identified as significant and implementing environmental management programmes to meet these. ♦ Developing an internal environmental audit procedure based on auditing against the significant aspects. ♦ Integrating areas of the EMS with the existing quality management system in order to avoid duplication of effort. ♦ Undergoing an external assessment process in order to achieve certification of the system. The thesis concludes that the systematic approach defined in ISO 14001 provided a mechanism that the organisation was able to adopt to bring about improvement in its environmental performance. The system was based on a thorough evaluation of the organisation's significant environmental aspects in order to bring about a reduction in its negative impacts. The ISO 14001 requirement for continual improvement is the key driver of the system, and this is what differentiates it from ISO 9000.
Resumo:
The objective of this thesis is to compare and contrast environmental licensing systems, for the wood panel industry, in a number of countries in order to determine which system is the best from an environmental and economic point of view. The thesis also examines the impact which government can have on industry and the type of licensing system in operation in a country. Initially, the thesis investigates the origins of the various environmental licensing systems which are in operation in Ireland, Scotland, Wales, France, USA and Canada. It then examines the Environmental Agencies which control and supervise industry in these countries. The impact which the type of government (i.e. unitary or federal) in charge in any particular country has on industry and the Regulatory Agency in that country is then described. Most of the mills in the thesis make a product called OSB (Oriented Strand Board) and the manufacturing process is briefly described in order to understand where the various emissions are generated. The main body of the thesis examines a number of environmental parameters which have emission limit values in the licenses examined, although not all of these parameters have emission limit values in all of the licenses. All of these parameters are used as indicators of the potential impact which the mill can have on the environment. They have been set at specific levels by the Environmental Agencies in the individual countries to control the impact of the mill. Following on from this, the two main types of air pollution control equipment (WESPs and RTOs) are described in regard to their function and capabilities. The mill licenses are then presented in the form of results tables which compare air results and water results separately. This is due to the fact that the most significant emission from this type of industry is to air. A matrix system is used to compare the licenses so that the comparison can be as objective as possible. The discussion examines all of the elements previously described and from this it was concluded that the IPC licensing system is the best from an environmental and economic point of view. It is a much more expensive system to operate than the other systems examined, but it is much more comprehensive and looks at the mill as a whole rather than fragmenting it. It was also seen that the type of environmental licensing system which is in place in a country can play a role in the locating of an industry as certain systems were seen to have more stringent standards attached to them. The type of standard in place in a country is in turn influenced by the type of government which is in place in that country.
Resumo:
Energy from waste (E/W) technologies in the form o f biogas plants, CHP plants and other municipal solid waste (MSW) conversion technologies, have been gaining steady ground in the provision o f energy throughout Europe and the UK. Urban Waste Water Treatment Plants (UWWTP) are utilising much o f the same biochemical processes common to these E/W plants. Previous studies on Centralised Anaerobic Digestion (CAD) within Ireland found that the legislative and economic conditions were not conducive to such an operation on the grounds o f low energy price for electric and heat energy, and due to the restrictive nature o f the allowable feedstocks. Recent changes to the Irish REFIT tariff on energy produced from Anaerobic digestion; alterations to the regulation o f the allowable use o f animal by products(ABP); the recent enactment o f the Renewable Energy D irective (09/28/EC) and a subsequent review o f the draft Biowaste Directive (2001) required that the issue o f decentralised energy production in Ireland be reassessed. In this instance the feasibility study is based on a extant rural community, centred around the village o f Woodford Co Galway. The review found that the prevailing conditions were now such that it was technically and economically feasible for this biochemical process to provide energy and waste treatment facilities at the above location. The review also outlines the last item which is preventing this process from becoming achievable, specifically the lack o f a digestate regulation on land spreading which deals specifically with biowaste. The study finds that the implementation o f the draft EU biowaste regulations, with amendments for Cr and Hg levels to match the proposed Irish regulation for compost, would ensure that Ireland has some o f the most restrictive regulations in Europe for this application. The delay in completing this piece o f legislation is preventing national energy and waste issues from being resolved in a planned and stepwise fashion. A proposed lay out for the new Integrated Waste from Energy Plant (IW/EP) is presented. Budget economic projections and alternative revenue streams are outlined. Finally a review o f the national policies regarding the Rural Development Plan (RDP), the Rural Planning Guidelines (RPG) and the National Renewable Energy Action Plan (NREAP) are examined against the relevant EU directives.
Resumo:
This study utilised recent developments in forensic aromatic hydrocarbon fingerprint analysis to characterise and identify specific biogenic, pyrogenic and petrogenic contamination. The fingerprinting and data interpretation techniques discussed include the recognition of: The distribution patterns of hydrocarbons (alkylated naphthalene, phenanthrene, dibenzothiophene, fluorene, chrysene and phenol isomers), • Analysis of “source-specific marker” compounds (individual saturated hydrocarbons, including n-alkanes (n-C5 through 0-C40) • Selected benzene, toluene, ethylbenzene and xylene isomers (BTEX), • The recalcitrant isoprenoids; pristane and phytane and • The determination of diagnostic ratios of specific petroleum / non-petroleum constituents, and the application of various statistical and numerical analysis tools. An unknown sample from the Irish Environmental Protection Agency (EPA) for origin characterisation was subjected to analysis by gas chromatography utilising both flame ionisation and mass spectral detection techniques in comparison to known reference materials. The percentage of the individual Polycyclic Aromatic Hydrocarbons (PAIIs) and biomarker concentrations in the unknown sample were normalised to the sum of the analytes and the results were compared with the corresponding results with a range of reference materials. In addition, to the determination of conventional diagnostic PAH and biomarker ratios, a number of “source-specific markers” isomeric PAHs within the same alkylation levels were determined, and their relative abundance ratios were computed in order to definitively identify and differentiate the various sources. Statistical logarithmic star plots were generated from both sets of data to give a pictorial representation of the comparison between the unknown sample and reference products. The study successfully characterised the unknown sample as being contaminated with a “coal tar” and clearly demonstrates the future role of compound ratio analysis (CORAT) in the identification of possible source contaminants.
Resumo:
This project focused on the investigation and the development of a chemical sensing system for the determination of chromium Cr6+ and a bio-reactor followed by electrochemical detection at a glassy carbon electrode, for the determination of organochlorine compounds. The conjugation of Cr6+ with 1,5-diphenylcarbazide was studied at various types of electrodes such as glassy carbon, ultra-trace epoxy-graphite, chemically or un-modified carbon-paste and dropping-mercury. The cyclic voltammetric behaviour of the complex was also investigated. In addition, the possibility of developing a chemical sensor, Le. an electrochemical probe capable of sensing Cr6+ through its complexation with 1,5-diphenylacarbazide was studied. The conjugations of l-chloro-2,4-dinitrobenzene, 2,4-dichloronitrobenzene and ethacrynic, which are electrophilic organochlorine compounds, with reduced glutathione, were studied in order to test the bioreactor developed, based on the immobilisation of glutathione s-transferase. This was carried out at different types of electrodes such as glassy-carbon, gold, silver, platinum, epoxy-graphite, hangingmercury, and ferrocene-modified rotating-disc electrodes.