6 resultados para CHEMICAL PROCESS SYSTEMS

em Galway Mayo Institute of Technology, Ireland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Historically, shifts to reduced and no-tillage management for production of crops were fostered by needs to decrease soil erosion and loss of organic matter, reduce fuel and labour costs and conserve soil water, as compared with conventional fallow tillage management. Recent interest in maintaining soil quality has been stimulated by a renewed awareness of the importance of soil condition to both the sustainability of agricultural production systems and environmental quality (Doran and Parkin, 1996). The aim of this project was to determine the impact on the physical, chemical and microbiological status of the soil of conventional and reduced tillage. It has been suggested that the reduced soil disturbance associated with the tine cultivator improves soil structure, increases nutrient content in the top 10cm of soil, increases microbial activity and improves physical characteristics. From this study it was determined that the environmental benefits linked to reduced tillage in literature, did not develop in the first two years of this programmes implementation. The results of this study determined that soil nutrients did not increase in concentration in the top 10 cm of soil under reduced cultivation. The only exception was exchangeable potassium. As potassium is not a mobile nutrient its movement is dependent on soil disturbance, therefore under reduced cultivation its concentration was allowed to accumulate in the upper horizon of the soil profile. Microbial activity was greater in the conventionally tilled treatments, as determined by total aerobic bacterial numbers. This could be due to the increased rates of soil aeration in this treatment. Numbers of aerobic bacteria were greater in the conventional tillage treatments at both incubation temperatures of 22 and 32° C. The physical characteristics of the soil determined, indicate that below the depth of soil cultivation, cone penetration resistance increases. Therefore the reduced cultivation treatments would be more prone to soil compaction, higher in the soil profile.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent studies have shown that septic tank systems are a major source of groundwater pollution. Many public health workers feel that the most cri^cal aspect of the use of septic tanks as a means of sewage disposal is the contamination of private water wells with attendant human health hazards. In this study the movement and attenuation of septic tank effluents in a range of soil/overburden types and hydrogeological situations was investigated. The suitability of a number of chemical and biological tracer materials to monitor the movement of septic tank effluent constituents to groundwater sources was also examined. The investigation was divided into three separate but inteiTelated sections. In the first section of the study the movement of septic tank effluent from two soil treatment systems was investigated by direct measurements of soil nutrient concentrations and enteric bacterial numbers in the soil beneath and downgradient of the test systems. Two sites with different soil types and hydrogeological characteristics were used. The results indicated that the attenuation of the effluent in both of the treatment systems was incomplete. Migration of nitrate, ammonium, phosphate and fecal bacteria to a depth of 50 cm beneath the inverts of the distribution tiles was demonstrated on all sampling occasions. The lateral migration of the pollutants was less pronounced, although on occasions high nutrients levels and fecal bacterial numbers were detected at a lateral distance of 4.0 m downgradient of the test systems. There was evidence that the degree and extent of effluent migration was increased after periods of heavy or prolonged rainfall when the attenuating properties of the treatment systems were reduced as a result of saturation of the soil. The second part of the study examined the contamination of groundwaters downgradient of septic tank soil treatment systems. Three test sites were used in the investigation. The sites were chosen because of differences in the thicknesses and nature of the unsaturated zone available for effluent attenuation at each of the locations. A series of groundwater monitoring boreholes were installed downgradient of the test systems at each of the sites and these were sampled regularly to assess the efficiency of the overburden material in reducing the polluting potential of the wastewater. Effluent attenuation in the septic tank treatment systems was shown to be incomplete, resulting in chemical and microbiological contamination of the groundwaters downgradient of the systems. The nature and severity of groundwater contamination was dependent on the composition and thickness of the unsaturated zone and the extent of weathering in the underlying saturated bedrock. The movement of septic tank effluent through soil/overburdens to groundwater sources was investigated by adding a range of chemical and biological tracer materials to the three septic tank systems used in section two of the study. The results demonstrated that a single tracer type cannot be used to accurately monitor the movement of all effluent constituents through soils to groundwater. The combined use of lithium bromide and endospores of Bacillus globigii was found to give an accurate indication of the movement of both the chemical and biological effluent constituents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

All organisations make some contribution to the degradation of the environment through their use of resources and production of waste. Environmental management systems (EMS) standards can provide a tool for companies to systematically reduce their environmental impacts. ISO 14001 was published in 1996. This fitted in with plans of the case study company to take proactive action in this area, even though there was no legislative requirement for them to do so. As EMS implementation was a new area at the time, appropriate methodologies were developed to address different aspects of the implementation, and ISO 14001 was successfully implemented in the company. The results of the primary research included: ♦ Drawing up a methodology for identifying and interpreting the environmental legislation that may have an impact on the organisation and compiling a register of such regulations. ♦ Developing a robust methodology for assessing significant environmental aspects and impacts and applying this to the software company. ♦ Establishing objectives and targets for those aspects identified as significant and implementing environmental management programmes to meet these. ♦ Developing an internal environmental audit procedure based on auditing against the significant aspects. ♦ Integrating areas of the EMS with the existing quality management system in order to avoid duplication of effort. ♦ Undergoing an external assessment process in order to achieve certification of the system. The thesis concludes that the systematic approach defined in ISO 14001 provided a mechanism that the organisation was able to adopt to bring about improvement in its environmental performance. The system was based on a thorough evaluation of the organisation's significant environmental aspects in order to bring about a reduction in its negative impacts. The ISO 14001 requirement for continual improvement is the key driver of the system, and this is what differentiates it from ISO 9000.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this thesis is to compare and contrast environmental licensing systems, for the wood panel industry, in a number of countries in order to determine which system is the best from an environmental and economic point of view. The thesis also examines the impact which government can have on industry and the type of licensing system in operation in a country. Initially, the thesis investigates the origins of the various environmental licensing systems which are in operation in Ireland, Scotland, Wales, France, USA and Canada. It then examines the Environmental Agencies which control and supervise industry in these countries. The impact which the type of government (i.e. unitary or federal) in charge in any particular country has on industry and the Regulatory Agency in that country is then described. Most of the mills in the thesis make a product called OSB (Oriented Strand Board) and the manufacturing process is briefly described in order to understand where the various emissions are generated. The main body of the thesis examines a number of environmental parameters which have emission limit values in the licenses examined, although not all of these parameters have emission limit values in all of the licenses. All of these parameters are used as indicators of the potential impact which the mill can have on the environment. They have been set at specific levels by the Environmental Agencies in the individual countries to control the impact of the mill. Following on from this, the two main types of air pollution control equipment (WESPs and RTOs) are described in regard to their function and capabilities. The mill licenses are then presented in the form of results tables which compare air results and water results separately. This is due to the fact that the most significant emission from this type of industry is to air. A matrix system is used to compare the licenses so that the comparison can be as objective as possible. The discussion examines all of the elements previously described and from this it was concluded that the IPC licensing system is the best from an environmental and economic point of view. It is a much more expensive system to operate than the other systems examined, but it is much more comprehensive and looks at the mill as a whole rather than fragmenting it. It was also seen that the type of environmental licensing system which is in place in a country can play a role in the locating of an industry as certain systems were seen to have more stringent standards attached to them. The type of standard in place in a country is in turn influenced by the type of government which is in place in that country.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This project focused on the investigation and the development of a chemical sensing system for the determination of chromium Cr6+ and a bio-reactor followed by electrochemical detection at a glassy carbon electrode, for the determination of organochlorine compounds. The conjugation of Cr6+ with 1,5-diphenylcarbazide was studied at various types of electrodes such as glassy carbon, ultra-trace epoxy-graphite, chemically or un-modified carbon-paste and dropping-mercury. The cyclic voltammetric behaviour of the complex was also investigated. In addition, the possibility of developing a chemical sensor, Le. an electrochemical probe capable of sensing Cr6+ through its complexation with 1,5-diphenylacarbazide was studied. The conjugations of l-chloro-2,4-dinitrobenzene, 2,4-dichloronitrobenzene and ethacrynic, which are electrophilic organochlorine compounds, with reduced glutathione, were studied in order to test the bioreactor developed, based on the immobilisation of glutathione s-transferase. This was carried out at different types of electrodes such as glassy-carbon, gold, silver, platinum, epoxy-graphite, hangingmercury, and ferrocene-modified rotating-disc electrodes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the determinism of the AS-lnterface network and the 3 main families of control systems, which may use it, namely PLC, PC and RTOS. During the course of this study the PROFIBUS and Ethernet field level networks were also considered in order to ensure that they would not introduce unacceptable latencies into the overall control system. This research demonstrated that an incorrectly configured Ethernet network introduces unacceptable variable duration latencies into the control system, thus care must be exercised if the determinism of a control system is not to be compromised. This study introduces a new concept of using statistics and process capability metrics in the form of CPk values, to specify how suitable a control system is for a given control task. The PLC systems, which were tested, demonstrated extremely deterministic responses, but when a large number of iterations were introduced in the user program, the mean control system latency was much too great for an AS-I network. Thus the PLC was found to be unsuitable for an AS-I network if a large, complex user program Is required. The PC systems, which were tested were non-deterministic and had latencies of variable duration. These latencies became extremely exaggerated when a graphing ActiveX was included in the control application. These PC systems also exhibited a non-normal frequency distribution of control system latencies, and as such are unsuitable for implementation with an AS-I network. The RTOS system, which was tested, overcame the problems identified with the PLC systems and produced an extremely deterministic response, even when a large number of iterations were introduced in the user program. The RTOS system, which was tested, is capable of providing a suitable deterministic control system response, even when an extremely large, complex user program is required.