4 resultados para termination of no win no fee retainer
Resumo:
BACKGROUND: This study's objective was to evaluate the role of psychological adjustment in the decision-making process to have an abortion and explore individual variables that might influence this decision. METHODS: In this cross-sectional study, we sequentially enrolled 150 women who made the decision to voluntarily terminate a pregnancy in Maternity Dr. Alfredo da Costa, in Lisbon, Portugal, between September 2008 and June 2009. The instruments were the Depression, Anxiety and Stress Scale (DASS), Satisfaction with Social Support Scale (SSSS), Emotional Assessment Scale (EAS), Decision Conflict Scale (DCS), and Beliefs and Values Questionnaire (BVQ). We analyzed the data using Student's T-tests, MANOVA, ANOVA, Tukey's post-hoc tests and CATPCA. Statistically significant effects were accepted for p<0.05. RESULTS: The participants found the decision difficult and emotionally demanding, although they also identified it as a low conflict decision. The prevailing emotions were sadness, fear and stress; but despite these feelings, the participants remained psychologically adjusted in the moment they decided to have an abortion. The resolution to terminate the pregnancy was essentially shared with supportive people and it was mostly motivated by socio-economic issues. The different beliefs and values found in this sample, and their possible associations are discussed. CONCLUSION: Despite high levels of stress, the women were psychologically adjusted at the time of making the decision to terminate the pregnancy. However, opposing what has been previously reported, the women presented high levels of sadness and fear, showing that this decision was hard to make, triggering disruptive emotions.
Resumo:
Introduction: Anatomical variations of the extensor tendons to the fingers are of great clinical interest, due to the relatively high frequency of tendon injury in clinical practice. Material and methods: During routine dissection of the right upper limb of a 67-year-old female preserved corpse, the extensor indicis proprius (EIP) muscle belly originated 3 independent tendons, each with a separate fascial sheath, forming a triple EIP tendon. There was a larger tendon, which occupied a central position, that represented the usual single EIP tendon. In addition, there were two thinner radial and ulnar accessory EIP tendons. The radial-EIP tendon crossed deep to the extensor digitorum communis (EDC) tendon to the index finger in the distal half of the dorsum of the hand to reach the radial side of the extensor expansion hood of the index finger. Discussion: According to the literature, the frequency of a triple EIP tendon ranges from 0%, to as high as 7%, although most authors do not acknowledge the presence of this variant in their series. This variant of the EIP tendon, in which the radial-EIP terminated laterally to the termination of the tendon of the EDC to the index finger, may be a source of confusion intraoperatively, as the EIP tendon has traditionally been identified on the basis of its ulnar location with respect to the EDC tendon. Conclusion: The possibility of a triple EIP tendon should certainly be born in mind by all surgeons when performing tendon repairs, tenoplasties or tendon transfers.
Resumo:
INTRODUCTION: Vagal activity is thought to influence atrial electrophysiological properties and play a role in the initiation and maintenance of atrial fibrillation (AF). In this study, we assessed the effects of acute vagal stimulation (vagus_stim) on atrial conduction times, atrial and pulmonary vein (PV) refractoriness, and vulnerability to induction of AF in the rabbit heart with intact autonomic innervation. METHODS: An open-chest epicardial approach was performed in 11 rabbits (New Zealand; 3.9-5.0 kg), anesthetized and artificially ventilated after neuromuscular blockade. A 3-lead ECG was obtained. Atrial electrograms were recorded along the atria, from right to left (four monopolar electrodes), together with a circular electrode adapted for proximal left PV assessment. Acute vagus nerve stimulation was obtained with bipolar electrodes (20 Hz). Epicardial activation was recorded in sinus rhythm, and the conduction time from right (RA) to left atrium (LA), and from RA to PVs, was measured in basal conditions and during vagus_stim. The atrial effective refractory period (ERP) and dispersion of refractoriness (Disp_A) were analyzed. Vulnerability to AF induction was assessed at the right (RAA) and left (LAA) atrial appendages and the PVs. Atrial stimulation (50 Hz) was performed alone or combined with vagus_stim. Heart rate and blood pressure were monitored. RESULTS: In basal conditions, there was a significant delay in conduction from RA to PVs, not influenced by vagus_stim, and the PV ERPs were shorter than those measured in LA and LAA, but without significant differences compared to RA and RAA. During vagus_stim, conduction times between RA and LA increased from 16+8 ms to 27+6 ms (p < 0.05) and ERPs shortened significantly in RA, LAA and LA (p < 0.05), but not in RAA. There were no significant differences in Disp_A. AF induction was reproducible in 45% of cases at 50 Hz and in 100% at 50 Hz+vagus_stim (p < 0.05). The duration of inducible AF increased from 1.0 +/- 0.2 s to 12.0 +/- 4.5 s with 50 Hz+vagus_stim (p < 0.01). AF lasted >10 s in 45.4% of rabbits during vagus_stim, and ceased after vagus_stim in 4 out of these 5 cases. In 3 animals, PV tachycardia, with fibrillatory conduction, induced with 50 Hz PV pacing during vagus_stim. CONCLUSIONS: Vagus_stim reduces interatrial conduction velocity and significantly shortens atrial ERP, contributing to the induction and duration of AF episodes in the in vivo rabbit heart. This model may be useful for the assessment of autonomic influence on the pathophysiology of AF.
Resumo:
Objectives: Chorionic Vilus Sampling (CVS) has several advantages over amniocentesis: it may be performed at an earlier gestational age, the results are quicker to obtain and there’s a lower miscarriage risk – 1%. However, the higher prevalence of discrepant fetal and vilus sampling material’s karyotype findings is a disadvantage of this technique – 0.5%. This is caused, amongst other causes, by placental mosaicism which consists of two genetically different cell lines. There are three types of placental mosaicism according to the abnormal cell line location: Type I – in the cytotrophoblast; Type II – in the vilus’ stroma; Type III – in both the above locations. Material and Methods: We present a case report about a 36-year-old pregnant woman going through our Department’s 1st trimester combined screening program; a CVS was performed, which showed Confined Placental Mosaicism (CPM). Results and Conclusion: Although the pregnant woman was in the low-risk group for aneuploidy, the patient wanted the cytogenetic study to be performed in order to reduce maternal anxiety. CVS was performed at the gestational age of 12 weeks + 5 days and the karyotype was 47XY+2/46XY. For the correct interpretation of this data an amniocentesis was performed at the gestational age of 15 weeks + 6 days, which showed a 46XY karyotype. We therefore conclude that the cytogenetic analysis of the CVS was the result of a CPM. A careful follow-up including fetal echocardiogram and seriated ultrasonographic monitoring was used to safely exclude malformations and fetal growth restriction. We verified no occurences throughout pregnancy, delivery and perinatal period. CVS practice was recently implemented in our country and has many advantages over amniocentesis. Besides the fact that an earlier gestational age usually means less affective bonding to the fetus and therefore makes medical termination of pregnancy somewhat less difficult, one should consider specific situations like the one reported in which CPM may be diagnosed. This condition is associated with increased risk of fetal growth restriction, so the clinician should be aware of the need for a more careful follow-up, since perinatal complications, which should be anticipated and treated, can be expected in 16-21% of these cases.