4 resultados para single channel algorithm
Resumo:
INTRODUCTION: ABO-incompatible liver transplantation (ABOi LT) is considered to be a rescue option in emergency transplantation. Herein, we have reported our experience with ABOi LT including long-term survival and major complications in these situations. PATIENT AND METHODS: ABOi LT was performed in cases of severe hepatic failure with imminent death. The standard immunosuppression consisted of basiliximab, corticosteroids, tacrolimus, and mycophenolate mofetil. Pretransplantation patients with anti-ABO titers above 16 underwent plasmapheresis. If the titer was above 128, intravenous immunoglobulin (IVIG) was added at the end of plasmapheresis. The therapeutic approach was based on the clinical situation, hepatic function, and titer evolution. A rapid increase in titer required five consecutive plasmapheresis sessions followed by administration of IVIG, and at the end of the fifth session, rituximab. RESULTS: From January 2009 to July 2012, 10 patients, including 4 men and 6 women of mean age 47.8 years (range, 29 to 64 years), underwent ABOi LT. At a mean follow-up of 19.6 months (range, 2 days to 39 months), 5 patients are alive including 4 with their original grafts. One patient was retransplanted at 9 months. Major complications were infections, which were responsible for 3 deaths due to multiorgan septic failure (2 during the first month); rejection episodes (4 biopsy-proven of humoral rejections in 3 patients and 1 cellular rejection) and biliary. CONCLUSION: The use of ABOi LT as a life-saving procedure is justifiable in emergencies when no other donor is available. With careful recipient selection close monitoring of hemagglutinins and specific immunosuppression we have obtained acceptable outcomes.
Resumo:
PURPOSE: The Genous™ stent (GS) is designed to accelerate endothelization, which is potentially useful in the pro-thrombotic environment of ST-elevation acute myocardial infarction (STEMI). We aimed to evaluate the safety and effectiveness of the GS in the first year following primary percutaneous coronary intervention (PCI) and to compare our results with the few previously published studies. METHODS AND MATERIALS: All patients admitted to a single center due to STEMI that underwent primary PCI using exclusively GS, between May 2006 and January 2012, were enrolled. The primary study endpoints were major adverse cardiac events (MACEs), defined as the composite of cardiac death, acute myocardial infarction and target vessel revascularization, at one and 12months. RESULTS: In the cohort of 109 patients (73.4% male, 59 ±12years), 24.8% were diabetic. PCI was performed in 116 lesions with angiographic success in 99.1%, using 148 GS with median diameter of 3.00mm (2.50-4.00) and median length of 15mm (9-33). Cumulative MACEs were 2.8% at one month and 6.4% at 12months. Three stent thromboses (2.8%), all subacute, and one stent restenosis (0.9%) occurred. These accounted for the four target vessel revascularizations (3.7%). At 12months, 33.9% of patients were not on dual antiplatelet therapy. CONCLUSIONS: GS was safe and effective in the first year following primary PCI in STEMI, with an apparently safer profile comparing with the previously published data. SUMMARY: We report the safety and effectiveness of the Genous™ stent (GS) in the first year following primary percutaneous coronary intervention in ST-elevation acute myocardial infarction. A comprehensive review of the few studies that have been published on this subject was included and some suggest a less safe profile of the GS. Our results and the critical review included may add information and reinforce the safety and effectiveness of the GS in ST-elevation in acute myocardial infarction.