9 resultados para prosthesis and implants
Resumo:
INTRODUCTION: Mitral regurgitation (MR) is the most common valvular disease and has recently become the target of a number of percutaneous approaches. The MitraClip is virtually the only device for which there is considerable experience, with more than 20,000 procedures performed worldwide. OBJECTIVE: To describe our initial experience of the percutaneous treatment of MR with the MitraClip device. METHODS: We describe the first six MitraClip cases performed in this institution (mean age 58.5 ± 13.1 years), with functional MR grade 4+ and New York Heart Association (NYHA) heart failure class III or IV (n=3), with a mean follow-up of 290 ± 145 days. RESULTS: Procedural success (MR ≤ 2+) was 100%. Total procedure time was 115.8 ± 23.7 min, with no in-hospital adverse events and discharge between the fourth and eighth day, and consistent improvement in the six-minute walk test (329.8 ± 98.42 vs. 385.33 ± 106.95 m) and in NYHA class (three patients improved by two NYHA classes). During follow-up there were two deaths, in two of the four patients who had been initially considered for heart transplantation. CONCLUSION: In patients with functional MR the MitraClip procedure is safe, with both a high implantation and immediate in-hospital success rate. A longer follow-up suggests that the clinical benefit decreases or disappears completely in patients with more advanced heart disease, namely those denied transplantation or on the heart transplant waiting list.
Resumo:
A 66-year-old female with Streptococcus viridans aortic and tricuspid infective endocarditis develops, during the course of antibiotic therapy, rupture of a right coronary sinus of Valsalva aneurysm to the right ventricle. An urgent cardiac surgery is preformed with implantation of a mechanical aortic prosthesis and a right coronary sinus plasty. Six months later a huge aortic pseudoaneurysm is diagnosed and she is submitted to a second uneventful surgery. A review is done for the significant features with discussion of diagnosis and therapy.
Resumo:
This paper focus on the most common used prosthesis for replacement of diseased heart valves, when repair is not feasible. A brief historical review is made. New prosthesis and the trends for the future are also addressed.
Resumo:
Background: Performing magnetic resonance imaging (MRI) on women with gynecological devices is a completely accepted practice. The goal of our review is to assess how safe it is to perform MRI on women using contraceptive implants or devices. Study Design: Literature review, searching in PubMed-Medline/Ovid for the following keywords: magnetic resonance imaging, intrauterine devices, Implanon® and Essure®. Results: Though plastic devices do not represent a contraindication to the use of the technique, those including metallic components have been submitted to several tests, after which they were classified as MR Conditional (devices presenting no risks in MR-specific environments) by the Food and Drug Administration. Thus, the use of MRI can be safely advised to women with this type of device as long as the magnetic resonance equipment is ≤3.0 T. Conclusions: Presently, there is no scientific evidence that contraindicates performing MRI on women with any kind of gynecological device. Therefore, this procedure is safe as long as it is performed under previously tested conditions.
Resumo:
BACKGROUND: Bioresorbable vascular scaffolds (BVS) were recently approved for percutaneous coronary intervention in Europe. The aim of this position statement is to review the information and studies on available BVS, to stimulate discussion on their use and to propose guidelines for this treatment option in Portugal. METHODS AND RESULTS: A working group was set up to reach a consensus based on current evidence, discussion of clinical case models and individual experience. The evidence suggests that currently available BVS can produce physiological and clinical improvements in selected patients. There are encouraging data on their durability and long-term safety. Initial indications were grouped into three categories: (a) consensual and appropriate - young patients, diabetic patients, left anterior descending artery, long lesions, diffuse disease, and hybrid strategy; (b) less consensual but possible - small collateral branches, stabilized acute coronary syndromes; and (c) inappropriate - left main disease, tortuosity, severe calcification. CONCLUSION: BVS are a viable treatment option based on the encouraging evidence of their applicability and physiological and clinical results. They should be used in appropriate indications and will require technical adaptations. Outcome monitoring and evaluation is essential to avoid inappropriate use. It is recommended that medical societies produce clinical guidelines based on high-quality registries as soon as possible.
Resumo:
STUDY OBJECTIVE: The main aim of this study is to evaluate the impact of adolescent pregnancy in the future contraceptive choices. A secondary aim is to verify whether these choices differ from those made after an abortion. DESIGN: Retrospective study. SETTING:Adolescent Unit of a tertiary care center. PARTICIPANTS:212 pregnant teenagers. INTERVENTIONS: Medical records review. MAIN OUTCOME MEASURES:Intended pregnancy rate and contraceptive methods used before and after pregnancy. For contraceptive choices after pregnancy we considered: Group 1 - teenagers who continued their pregnancy to delivery (n = 106) and Group 2 - the same number of adolescents who chose to terminate their pregnancy. RESULTS: The intended pregnancy rate was 14.2%. Prior to a pregnancy continued to delivery, the most widely used contraceptive method was the male condom (50.9%), followed by oral combined contraceptives (28.3%); 18.9% of adolescents were not using any contraceptive method. After pregnancy, contraceptive implant was chosen by 70.8% of subjects (P < .001) and the oral combined contraceptives remained the second most frequent option (17.9%, P = .058). Comparing these results with Group 2, we found that the outcome of the pregnancy was the main factor in the choices that were made. Thus, after a pregnancy continued to delivery, adolescents prefer the use of LARC [78.4% vs 40.5%, OR: 5,958 - 95% (2.914-12.181), P < .001)], especially contraceptive implants [70.8% vs 38.7%, OR: 4.371 - 95% (2.224-8.591), P < .001], to oral combined contraceptives [17.9% vs 57.5%, OR: 0.118 - 95% CI (0.054-0.258), P < .001]. CONCLUSION:Adolescent pregnancy and its outcome constitute a factor of change in future contraceptive choice.
Resumo:
OBJECTIVE:Endograft mural thrombus has been associated with stent graft or limb thrombosis after endovascular aneurysm repair (EVAR). This study aimed to identify clinical and morphologic determinants of endograft mural thrombus accumulation and its influence on thromboembolic events after EVAR. METHODS: A prospectively maintained database of patients treated by EVAR at a tertiary institution from 2000 to 2012 was analyzed. Patients treated for degenerative infrarenal abdominal aortic aneurysms and with available imaging for thrombus analysis were considered. All measurements were performed on three-dimensional center-lumen line computed tomography angiography (CTA) reconstructions. Patients with thrombus accumulation within the endograft's main body with a thickness >2 mm and an extension >25% of the main body's circumference were included in the study group and compared with a control group that included all remaining patients. Clinical and morphologic variables were assessed for association with significant thrombus accumulation within the endograft's main body by multivariate regression analysis. Estimates for freedom from thromboembolic events were obtained by Kaplan-Meier plots. RESULTS: Sixty-eight patients (16.4%) presented with endograft mural thrombus. Median follow-up time was 3.54 years (interquartile range, 1.99-5.47 years). In-graft mural thrombus was identified on 30-day CTA in 22 patients (32.4% of the study group), on 6-month CTA in 8 patients (11.8%), and on 1-year CTA in 17 patients (25%). Intraprosthetic thrombus progressively accumulated during the study period in 40 patients of the study group (55.8%). Overall, 17 patients (4.1%) presented with endograft or limb occlusions, 3 (4.4%) in the thrombus group and 14 (4.1%) in the control group (P = .89). Thirty-one patients (7.5%) received an aortouni-iliac (AUI) endograft. Two endograft occlusions were identified among AUI devices (6.5%; overall, 0.5%). None of these patients showed thrombotic deposits in the main body, nor were any outflow abnormalities identified on the immediately preceding CTA. Estimated freedom from thromboembolic events at 5 years was 95% in both groups (P = .97). Endograft thrombus accumulation was associated with >25% proximal aneurysm neck thrombus coverage at baseline (odds ratio [OR], 1.9; 95% confidence interval [CI], 1.1-3.3), neck length ≤ 15 mm (OR, 2.4; 95% CI, 1.3-4.2), proximal neck diameter ≥ 30 mm (OR, 2.4; 95% CI, 1.3-4.6), AUI (OR, 2.2; 95% CI, 1.8-5.5), or polyester-covered stent grafts (OR, 4.0; 95% CI, 2.2-7.3) and with main component "barrel-like" configuration (OR, 6.9; 95% CI, 1.7-28.3). CONCLUSIONS: Mural thrombus formation within the main body of the endograft is related to different endograft configurations, main body geometry, and device fabric but appears to have no association with the occurrence of thromboembolic events over time.
Resumo:
Pseudo-Kaposi sarcoma is a benign reactive vascular proliferation mainly involving the lower legs, which can be related to acquired chronic venous insufficiency or congenital arteriovenous malformations. In its most common presentation, acroangiodermatitis is seen in patients with chronic venous insufficiency of the lower limbs as an exaggeration of the stasis dermatitis. However, rare reports of acroangiodermatitis include descriptions in amputees (especially in those with poorly fitting suction-type devices), in patients undergoing hemodialysis (with lesions developing distally to arteriovenous shunts) and in patients with paralyzed legs. We report on a 28 year-old-male who presented pseudo-Kaposi's sarcoma in an amputation stump because of suction-socket lower limb prosthesis.