2 resultados para post and core technique


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: This study was designed to compare baseline data and clinical outcome between patients with prostate enlargement/benign prostatic hyperplasia (PE/BPH) who underwent unilateral and bilateral prostatic arterial embolization (PAE) for the relief of lower urinary tract symptoms (LUTS). METHODS: This single-center, ambispective cohort study compared 122 consecutive patients (mean age 66.7 years) with unilateral versus bilateral PAE from March 2009 to December 2011. Selective PAE was performed with 100- and 200-μm nonspherical polyvinyl alcohol (PVA) particles by a unilateral femoral approach. RESULTS: Bilateral PAE was performed in 103 (84.4 %) patients (group A). The remaining 19 (15.6 %) patients underwent unilateral PAE (group B). Mean follow-up time was 6.7 months in group A and 7.3 months in group B. Mean prostate volume, PSA, International prostate symptom score/quality of life (IPSS/QoL) and post-void residual volume (PVR) reduction, and peak flow rate (Qmax) improvement were 19.4 mL, 1.68 ng/mL, 11.8/2.0 points, 32.9 mL, and 3.9 mL/s in group A and 11.5 mL, 1.98 ng/mL, 8.9/1.4 points, 53.8 mL, and 4.58 mL/s in group B. Poor clinical outcome was observed in 24.3 % of patients from group A and 47.4 % from group B (p = 0.04). CONCLUSIONS: PAE is a safe and effective technique that can induce 48 % improvement in the IPSS score and a prostate volume reduction of 19 %, with good clinical outcome in up to 75 % of treated patients. Bilateral PAE seems to lead to better clinical results; however, up to 50 % of patients after unilateral PAE may have a good clinical outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Low-dose dobutamine stress echocardiography is a common and useful technique to assess myocardial viability in patients with ischemic cardiomyopathy. OBJECTIVE: To evaluate the use of low-dose dobutamine stress echocardiography in determining the functional status of patients with idiopathic dilated cardiomyopathy (IDCM). METHODS: Prospective study of 28 patients with IDCM by transthoracic echocardiography (2D), low-dose dobutamine stress echocardiography, cardiopulmonary exercise testing (CPET) and measurement of pro-BNP. RESULTS: The mean age of the population was 50.3 +/- 11.5 years, 9 female and 19 male. Mean ejection fraction was 32.1 +/- 9.8%. All were in sinus rhythm. The following parameters were analyzed in 2D echocardiography and after dobutamine: dimensions of left atrium (LA) and of left ventricle in diastole and systole, shortening fraction (%), left ventricular end-diastolic (EDV) and end-systolic volumes (ESV), ejection fraction (EF), and mitral inflow (E, A, E/A ratio and deceleration time). In CPET, we considered the following parameters: peak VO2 and % maximal peak VO2 attained. We compared echo results with CPET. There was a correlation between age and peak VO2 (r = -0.38 with p = 0.049). In 2D echo, there was a correlation between baseline EF and LA dimensions and peak VO2 (r = 0.45 / p = 0.004 and r = -0.49 / p = 0.014, respectively). After dobutamine echo, there was a correlation between some echo parameters and peak VO2: EF - r = 0.59 / p = 0.001, LA dimensions - r = 0.56 / p = 0.007, and ESV - r = -0.45 / p = 0.026. Percentage maximal peak VO2 attained correlated with LA dimensions measured in 2D echo and after dobutamine (r = -0.398 / p = 0.036 and r = -0.674 / p = 0.02 respectively) and EF after dobutamine (r = -0.389 / p = 0.04). The value of pro-BNP correlated with LA dimensions and baseline EF (r = 0.44 / p = 0.02 and r = -0.57 / p = 0.002, respectively), and the correlation was maintained after inotropic stimulation with dobutamine (r = 0.57 / p = 0.001 and r = -0.55 / p = 0.0039). CONCLUSION: Low-dose dobutamine stress echocardiography showed stronger correlations with cardiopulmonary exercise testing than the parameters evaluated by conventional echocardiography and could be used to determine the functional status of patients with dilated cardiomyopathy; patients with greater ejection fraction after inotropic stimulation had better cardiopulmonary tests.