5 resultados para optical motion capture


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The Genous™ stent (GS) is designed to accelerate endothelization, which is potentially useful in the pro-thrombotic environment of ST-elevation acute myocardial infarction (STEMI). We aimed to evaluate the safety and effectiveness of the GS in the first year following primary percutaneous coronary intervention (PCI) and to compare our results with the few previously published studies. METHODS AND MATERIALS: All patients admitted to a single center due to STEMI that underwent primary PCI using exclusively GS, between May 2006 and January 2012, were enrolled. The primary study endpoints were major adverse cardiac events (MACEs), defined as the composite of cardiac death, acute myocardial infarction and target vessel revascularization, at one and 12months. RESULTS: In the cohort of 109 patients (73.4% male, 59 ±12years), 24.8% were diabetic. PCI was performed in 116 lesions with angiographic success in 99.1%, using 148 GS with median diameter of 3.00mm (2.50-4.00) and median length of 15mm (9-33). Cumulative MACEs were 2.8% at one month and 6.4% at 12months. Three stent thromboses (2.8%), all subacute, and one stent restenosis (0.9%) occurred. These accounted for the four target vessel revascularizations (3.7%). At 12months, 33.9% of patients were not on dual antiplatelet therapy. CONCLUSIONS: GS was safe and effective in the first year following primary PCI in STEMI, with an apparently safer profile comparing with the previously published data. SUMMARY: We report the safety and effectiveness of the Genous™ stent (GS) in the first year following primary percutaneous coronary intervention in ST-elevation acute myocardial infarction. A comprehensive review of the few studies that have been published on this subject was included and some suggest a less safe profile of the GS. Our results and the critical review included may add information and reinforce the safety and effectiveness of the GS in ST-elevation in acute myocardial infarction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To evaluate the long-term clinical outcomes following percutaneous coronary intervention (PCI) with the Genous stent in an unselected population. METHODS: All patients admitted to a single center who underwent PCI using the GS exclusively, between May 2006 and May 2012, were enrolled, and a clinical follow-up of up to 60 months was carried out. The primary endpoint of major adverse cardiac event (MACE) rate was defined as the composite of cardiac death, acute myocardial infarction (AMI), and target lesion revascularization (TLR). RESULTS: Of the 450 patients included (75.1% male; 65.5 ± 11.7 years), 28.4% were diabetic and acute coronary syndrome was the reason for PCI in 76.4%. Angioplasty was performed in 524 lesions using 597 Genous stents, with angiographic success in 97.1%. At a median of 36 months of follow-up (range, 1-75 months), MACE, AMI, TLR, stent restenosis (SR), and stent thrombosis (ST) rates were 15.6%, 8.4%, 4.4%, 3.8%, and 2.2%, respectively. Between 12 and 24 months, the TLR, SR, and ST rates practically stabilized, up to 60 months. Bifurcation lesions were independently associated with MACE, TLR, and SR. CONCLUSION: This is the first study reporting clinical results with the Genous stent up to 60 months. The Genous stent was safe and effective in the long-term, in an unselected population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multifocal intraocular lenses (MF IOLs) have concentric optical zones with different dioptric power, enabling patients to have good visual acuity at multiple focal points. However, several optical limitations have been attributed to this particular design. The purpose of this study is to access the effect of MF IOLs design on the accuracy of retinal optical coherence tomography (OCT). Cross-sectional study conducted at the Refractive Surgery Department of Central Lisbon Hospital Center. Twenty-three eyes of 15 patients with a diffractive MF IOL and 27 eyes of 15 patients with an aspheric monofocal IOL were included in this study. All patients underwent OCT macular scans using Heidelberg Spectralis®. Macular thickness and volume values and image quality (Q factor) were compared between the two groups. There were no statistically significant differences between both groups regarding macular thickness or volume measurements. Retinal OCT image quality was significantly lower in the MF IOL group (p < 0.01). MF IOLs are associated with a significant decrease in OCT image quality. However, this fact does not seem to compromise the accuracy of spectral domain OCT retinal measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary optical coherence tomography has emerged as the most powerful in-vivo imaging modality to evaluate vessel structure in detail. It is a useful research tool that provides insights into the pathogenesis of coronary artery disease. This technology has an important clinical role that is still being developed. We review the evidence on the wide spectrum of potential clinical applications for coronary optical coherence tomography, which encompass the successive stages in coronary artery disease management: accurate lesion characterization and quantification of stenosis, guidance for the decision to perform percutaneous coronary intervention and subsequent planning, and evaluation of immediate and long-term results following intervention.