3 resultados para diagnostic methods
Resumo:
8A>C>86A G:EDGI: A patient diagnosed Wilson’s disease (WD) 22 years previously, successfully treated initially with zinc, developed neuropsychiatric disease after years of irregular therapy. Reassuming zinc therapy was successful. After a normal pregnancy, she had two therapeutic abortions for corpus callosum agenesis, and a missed abortion. We review the genetics, physiopathology, clinics and imagiologic response to zinc therapy, the problems of pregnancy in WD, advising to maintain therapy. A hypothetic cause for fetus brain anomaly would be hypocupremia due to zinc therapy, confronting with two other possibilities, one related to Wilson’s disease in itself, other due to a congenital syndrome of agenesis of the corpus callosum, impossible to diagnose by our available diagnostic methods.
Resumo:
Despite its efficacy, including in the prevention of vertical transmission, the antiretroviral nevirapine is associated with severe idiosyncratic hepatotoxicity and skin rash. The mechanisms underlying nevirapine toxicity are not fully understood, but drug bioactivation to reactive metabolites capable of forming stable protein adducts is thought to be involved. This hypothesis is based on the paradigm that drug reactive metabolites have the potential to bind to self-proteins, which results in drug-modified proteins being perceived as foreign by the immune system. The aim of the present work was to identify hemoglobin adducts in HIV patients as biomarkers of nevirapine haptenation upon bioactivation. The ultimate goal is to develop diagnostic methods for predicting the onset of nevirapine-induced toxic reactions. All included subjects were adults on nevirapine-containing antiretroviral therapy for at least 1month. The protocol received prior approval from the Hospital Ethics Committees and patients gave their written informed consent. Nevirapine-derived adducts with the N-terminal valine of hemoglobin were analyzed by an established liquid chromatography-electrospray ionization-tandem mass spectrometry method and characterized on the basis of retention time and mass spectrometric fragmentation pattern by comparison with adduct standards prepared synthetically. The nevirapine adducts were detected in 12/13 patient samples, and quantified in 11/12 samples (2.58±0.8 fmol/g of hemoglobin). This work represents the first evidence of nevirapine-protein adduct formation in man and confirms the ability of nevirapine to modify self-proteins, thus providing clues to the molecular mechanisms underlying nevirapine toxicity. Moreover, the possibility of assessing nevirapine-protein adduct levels has the potential to become useful for predicting the onset of nevirapine-induced adverse reactions.
Resumo:
Background: A new method for determining serum specific IgE (IMMULITE“ 2000 3gAllergy) has recently become available. Objective: To evaluate the clinical performance of IMMULITE 2000 in the diagnosis of cow’s milk allergy compared with that of UniCAP“. Additionally, we verified the behavior of both methods at two diagnostic decision points proposed by other authors. Methods: The study population consisted of 31 children with cow’s milk allergy (group A) and a control group of 19 atopic children without food allergy(group B). A blood sample from each child was tested using both methods and the results were compared. Results: In group A, the values for cow’s milk IgE ranged from 0.35 kU/L (the lowest common detection limit) to above 100 kU/L. In group B, the values were less than 1.1 kU/L for IMMULITE 2000 and less than 1.6 kU/L for UniCAP. An agreement of 90 % in IgE classes was obtained. Both methods demonstrated exactly the same diagnostic performance(sensitivity: 100 %; specificity: 78.9 %; negative predictive value: 100%; positive predictive value: 84.6%;efficiency: 90.2 %). The evaluation of the two methods at the two different decision points proposed in the literature showed a better positive predictive value with UniCAP, but we obtained equivalent performance with IMMULITE 2000 by choosing higher cutoff values. Conclusions: We conclude that IMMULITE 2000 is as effective as UniCAP in the diagnosis of cow’s milk allergy. Both methods can be used to obtain site-specific decision points that are population, age and disease dependent.