4 resultados para cinética do VO2
Resumo:
INTRODUCTION: Low-dose dobutamine stress echocardiography is a common and useful technique to assess myocardial viability in patients with ischemic cardiomyopathy. OBJECTIVE: To evaluate the use of low-dose dobutamine stress echocardiography in determining the functional status of patients with idiopathic dilated cardiomyopathy (IDCM). METHODS: Prospective study of 28 patients with IDCM by transthoracic echocardiography (2D), low-dose dobutamine stress echocardiography, cardiopulmonary exercise testing (CPET) and measurement of pro-BNP. RESULTS: The mean age of the population was 50.3 +/- 11.5 years, 9 female and 19 male. Mean ejection fraction was 32.1 +/- 9.8%. All were in sinus rhythm. The following parameters were analyzed in 2D echocardiography and after dobutamine: dimensions of left atrium (LA) and of left ventricle in diastole and systole, shortening fraction (%), left ventricular end-diastolic (EDV) and end-systolic volumes (ESV), ejection fraction (EF), and mitral inflow (E, A, E/A ratio and deceleration time). In CPET, we considered the following parameters: peak VO2 and % maximal peak VO2 attained. We compared echo results with CPET. There was a correlation between age and peak VO2 (r = -0.38 with p = 0.049). In 2D echo, there was a correlation between baseline EF and LA dimensions and peak VO2 (r = 0.45 / p = 0.004 and r = -0.49 / p = 0.014, respectively). After dobutamine echo, there was a correlation between some echo parameters and peak VO2: EF - r = 0.59 / p = 0.001, LA dimensions - r = 0.56 / p = 0.007, and ESV - r = -0.45 / p = 0.026. Percentage maximal peak VO2 attained correlated with LA dimensions measured in 2D echo and after dobutamine (r = -0.398 / p = 0.036 and r = -0.674 / p = 0.02 respectively) and EF after dobutamine (r = -0.389 / p = 0.04). The value of pro-BNP correlated with LA dimensions and baseline EF (r = 0.44 / p = 0.02 and r = -0.57 / p = 0.002, respectively), and the correlation was maintained after inotropic stimulation with dobutamine (r = 0.57 / p = 0.001 and r = -0.55 / p = 0.0039). CONCLUSION: Low-dose dobutamine stress echocardiography showed stronger correlations with cardiopulmonary exercise testing than the parameters evaluated by conventional echocardiography and could be used to determine the functional status of patients with dilated cardiomyopathy; patients with greater ejection fraction after inotropic stimulation had better cardiopulmonary tests.
Resumo:
Recentemente, surgiram alguns trabalhos que ressaltaram a importância do cálculo do volume da aurícula esquerda (VAE) como um marcador de eventos cardíacos adversos. Foi objectivo deste estudo avaliar a importância prognóstica deste parâmetro em doentes (dts) com deficiente função ventricular esquerda e correlacioná-lo com outros parâmetros clássicos de prognóstico – consumo de O2 (VO2 max) e pro-BNP (pBNP). Métodos: Analisou-se o volume da aurícula esquerda (VAE) por método de Simpson, numa população de 35 dts com cardiopatia dilatada (idiopática e isquémica) com fracção de ejecção (FE) 31±9,6% doentes (dts) eram de sexo masculino e a média de idades foi de 50,5±10,5 anos. Toda a população efectuou estudos de ecocardiografia convencional (incluindo avaliação por M-mode, bidimensional e Doppler), prova cardiorespiratória (VO2max) e doseamento de pro-BNP. O tempo médio de seguimento foi de 24 ± 4 meses, tendo-se considerado como eventos cardíacos (EC): internamento por insuficiência cardíaca, transplante e morte. Resultados: Dos parâmetros da ecocardiografia - o diâmetro da AE foi de 46,6±5,7mm, as dimensões do VE em diástole – 73,5±10mm e em sístole -58,9±11mm, a média da fracção de ejecção foi de 31±9,6%, o VAE foi de 78,6±33 ml, os volumes do VE foram de 214±82ml em diástole e de 153±75ml em sístole, 15 dts tinham padrão restritivo de enchimento ventricular (E/A>2), a média da área (Doppler cor) da insuficiência mitral foi de 4±3,3cm2, 14 dts tinham E/E’>15. O VO2 max médio foi de 20±5,8ml/kg/min e o pro-BNP de 3146±4629pg/mL. Para além da correlação de outros parâmetros clássicos ecocardiográficos com o prognóstico (volumes VE, FE e E/E’), o VAE e o volume indexado da AE (VAE/SC) mostraram uma correlação com o prognóstico (EC) com r=0,4 (p=0,02) que não se verificou para o diâmetro da AE (p=ns). Em relação à tolerância ao esforço, houve uma correlação inversa entre o diâmetro, o volume e o volume indexado da AE e o VO2max, com maior significado estatístico para o VAE e VAE/SC com r=-0,48, p=0,008. Quanto ao pro-BNP, quer o diâmetro, quer o VAE (ou volume indexado) tiverem o mesmo nível de significado estatístico (r=0,43; p=0,02). O valor predictivo de eventos (curvas ROC) para o VAE foi de 70ml e de 37ml/m2 para o VAE/m2. Conclusão: O volume da aurícula esquerda/volume indexado é um parâmetro ecocardiográfico com significado prognóstico em dts com deficiente função ventricular esquerda, correlacionando-se com a tolerância ao esforço e pro-BNP.
Resumo:
Previous studies have shown that a ratio of early transmitral flow velocity to early diastolic velocity of the mitral annulus (E/E') of > 15, obtained by tissue Doppler imaging (TDI), correlates with left ventricular filling pressure. OBJECTIVE: The aim of our study was to assess whether E/E' provides prognostic information in patients with dilated cardiomyopathy. METHODS: We studied 33 patients with dilated cardiomyopathy and mean ejection fraction of 31%. All the patients underwent routine two-dimensional and Doppler echocardiographic examination and TDI to determine early peak velocity of the mitral annulus. Pro-B-type natriuretic peptide (pro-BNP) and peak oxygen consumption (VO2max) were also measured. Patients were divided into two groups according to the value of E/E': Group I (n = 15 patients) with E/E' > or = 15 and Group II (n = 18 patients) with E/E' < 15. Patients were followed for 12+/-4 months; new hospital admission due to heart failure, heart transplantation and death were considered as cardiac events. RESULTS: There were significant differences between the two groups in conventional two-dimensional echocardiographic measurements (dimensions and ejection fraction) and Doppler parameters (mitral inflow). With regard to mitral annular velocities obtained by TDI at two different points (septum and lateral wall), the E', A' and S' velocities differed significantly between the two groups, with lower velocities in Group I. Systolic velocity measured in the lateral portion of the mitral annulus showed the most significant difference: Group I - 4.46 cm/sec versus Group II - 7.19 cm/sec, p < 0.00001. Pro-BNP was 5622 pg/ml in Group I, and 1254 pg/ml in Group II, p = 0.004. VO2 max was significantly different between the two groups: Group I - 17.6 ml/kg/min versus Group II - 22.8 ml/kg/min, p = 0.004. During follow-up, events were more common in Group I, with 9 patients (60%) having events, while in Group II, the event rate was 11.1% (2 patients), p = 0.004. CONCLUSION: The ratio of early transmitral flow velocity to early diastolic velocity of the mitral annulus is a powerful predictor of clinical outcome. Lower velocities of mitral annulus on TDI are expected in patients with E/E' > or = 15. Systolic velocities of under 5 cm/sec measured in the lateral portion of the mitral annulus appeared to be strongly related to prognosis.
Resumo:
Objectivo e desenho: estudo prospectivo de avaliação da possibilidade de aplicação e utilidade clínica da ecocardiografia transtorácica (ETT) na avaliação da hpotensão numa Unidade de Cuidados Intensivos Polivalente (UCIP). Local: UCIP de 16 camas. Material e métodos: Incluídos doentes com hipotensão (pressão arterial sistólica 90 mmHg ou média (PAM) < 60 mmHg, que não respondeu à administração de soros no espaço de 30 minutos). Os objectivos do ETT foram: excluir cardiopatia estrutural grave, avaliação de outras alterações cardíacas (alterações das dimensões das cavidades e função ventricular esquerda), análise da veia cava inferior (VCI) e determinação do índex cardíaco (IC). Resultados: de um total de 208 doentes foram incluídos 198 (4,5% de exames impossíveis), com média etária de 63,4 +/- 16,2 anos, 129 do sexo masculino, APACHE II 30,1 +/- 9,9, SAPS II 68,8 +/- 20,5, SOFA 11,6 +/- 3,8 MODS 10,9 +/- 3,9. Observou-se uma mortalidade de 51% (n=101), e 168 (85,2%) doentes estavam ventilados. Oitenta e oito (44,4%) doentes apresentaram alterações cardíacas, dos quais 28 (14%) classificadas como graves: três valvulopatias aórticas graves, quatro endocardites, nove miocardiopatias dilatadas, dois tamponamentos (18 doentes com alterações graves insuspeitas, 9%), seis enfartes agudos do miocárdio, quatro alterações da cinética segmentar. Estes doentes apresentaram uma mortalidade e índices de gravidade mais elevados (p <0,001). Em relação ao IC, 157 doentes apresentaram um valor normal ou elevado, os quais apresentaram todos um valor de resistências ventriculares periféricas baixo. Por análise de regressão logística, verificou-se uma relação entre o índex da VCI e os dias de internamento (p = 0,05) e entre o IC, índex da VCI e a mortalidade (p =0,008 e 0,041 respectivamente). Conclusões: Observou-se uma elevada prevalência de patologia cardíaca entre os doentes admitidos numa UCIP com hipotensão (n =88, 44,4%), dos quais 14% consideradas graves. Estes doentes tiveram maior mortalidade e índices de gravidade mais elevados. A análise conjunta do IC e da VCI pode ser útil na definição do padrão hemodinâmico do doente hipotenso e certos parâmetros ecocardiográficos, em especial o índex da VCI, podem ser úteis no prognóstico destes doentes.