3 resultados para Zero Dynamic
Resumo:
Our purposes are to determine the impact of histological factors observed in zero-time biopsies on early post transplant kidney allograft function. We specifically want to compare the semi-quantitative Banff Classification of zero time biopsies with quantification of % cortical area fibrosis. Sixty three zero-time deceased donor allograft biopsies were retrospectively semiquantitatively scored using Banff classification. By adding the individual chronic parameters a Banff Chronic Sum (BCS) Score was generated. Percentage of cortical area Picro Sirius Red (%PSR) staining was assessed and calculated with a computer program. A negative linear regression between %PSR/ GFR at 3 year post-transplantation was established (Y=62.08 +-4.6412X; p=0.022). A significant negative correlation between arteriolar hyalinosis (rho=-0.375; p=0.005), chronic interstitial (rho=0.296; p=0.02) , chronic tubular ( rho=0.276; p=0.04) , chronic vascular (rho= -0.360;P=0.007), BCS (rho=-0.413; p=0.002) and GFR at 3 years were found. However, no correlation was found between % PSR, Ci, Ct or BCS. In multivariate linear regression the negative predictive factors of 3 years GFR were: BCS in histological model; donor kidney age, recipient age and black race in clinical model. The BCS seems a good and easy to perform tool, available to every pathologist, with significant predictive short-term value. The %PSR predicts short term kidney function in univariate study and involves extra-routine and expensive-time work. We think that %PSR must be regarded as a research instrument.
Resumo:
The purpose of our study was to evaluate the accuracy of dynamic incremental bolus-enhanced conventional CT (DICT) with intravenous contrast administration, early phase, in the diagnosis of malignancy of focal liver lesions. A total of 122 lesions were selected in 74 patients considering the following criteria: lesion diameter 10 mm or more, number of lesions less than six per study, except in multiple angiomatosis and the existence of a valid criteria of definitive diagnosis. Lesions were categorized into seven levels of diagnostic confidence of malignancy compared with the definitive diagnosis for acquisition of a receiver-operator-characteristic (ROC) curve analysis and to determine the sensitivity and specificity of the technique. Forty-six and 70 lesions were correctly diagnosed as malignant and benign, respectively; there were 2 false-positive and 4 false-negative diagnoses of malignancy and the sensitivity and specificity obtained were 92 and 97%. The DICT early phase was confirmed as a highly accurate method in the characterization and diagnosis of malignancy of focal liver lesions, requiring an optimal technical performance and judicious analysis of existing semiological data.