3 resultados para Validated Interval Software


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine if mid-term outcome following endovascular aneurysm repair (EVAR) with the Endurant Stent Graft (Medtronic, Santa Rosa, CA, USA) is influenced by severe proximal neck angulation. METHODS: A retrospective case-control study was performed using data from a prospective multicenter database. All measurements were obtained using dedicated reconstruction software and center-lumen line reconstruction. Patients with neck length >15 mm, infrarenal angle (β) >75°, and/or suprarenal angle (α) >60°, or neck length >10 mm with β >60°, and/or α >45° were compared with a matched control group. Primary endpoint was primary clinical success. Secondary endpoints were freedom from rupture, type 1A endoleak, stent fractures, freedom from neck-related reinterventions, and aneurysm-related adverse events. Morphological neck variation over time was also assessed. RESULTS: Forty-five patients were included in the study group and were compared with a matched control group with 65 patients. Median follow-up time was 49.5 months (range 30.5-58.4). The 4-year primary clinical success estimates were 83% and 80% for the angulated and nonangulated groups (p = .42). Proximal neck angulation did not affect primary clinical success in a multivariate model (hazard ratio 1.56, 95% confidence interval 0.55-4.41). Groups did not differ significantly in regard to freedom from rupture (p = .79), freedom from type 1A endoleak (p = .79), freedom from neck-related adverse events (p = .68), and neck-related reinterventions (p = .68). Neck angle reduction was more pronounced in patients with severe proximal neck angulation (mean Δα -15.6°, mean Δβ -30.6°) than in the control group (mean Δα -0.39°, mean Δβ -5.9°) (p < .001). CONCLUSION: Mid-term outcomes following EVAR with the Endurant Stent Graft were not influenced by severe proximal neck angulation in our population. Despite the conformability of the device, moderate aortic neck remodeling was identified in the group of patients with angulated neck anatomy on the first computed tomography scan after implantation with no important further remodeling afterwards. No device integrity failures were encountered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective:We aimed to identify the cut-off for risk of pre-eclampsia (PE) in Portuguese population by applying the first trimester prediction model from Fetal Medicine Foundation (FMF) in a prospective enrolled cohort of low risk pregnant women. Population and methods: A prospective cohort of low risk singleton pregnancies underwent routine first-trimester scree - ning from 2011 through 2013. Maternal characteristics, blood pressure, uterine artery Doppler, levels of pregnancy-associated plasma protein-A (PAPP-A) and free b-human chorionic gonadotropin were evaluated. The prediction of PE in first trimester was calculated through software Astraia, the outcome obtained from medical records and the cutoff value was subse quently calculated. Results:Of the 273 enrolled patients, 7 (2.6%) developed PE. In first trimester women who developed PE presented higher uterine arteries resistance, represented by higher values of lowest and mean uterine pulsatility index, p <0.005. There was no statistical significance among the remaining maternal characteristics, body mass index, blood pressure and PAPP-A. Using the FMF first trimester PE algorithm, an ideal cut-off of 0.045 (1/22) would correctly detect 71% women who developed PE for a 12% false positive rate and a likelihood ratio of 12.98 (area under the curve: 0.69; confidence interval 95%: 0.39-0.99). By applying the reported cutoff to our cohort, we would obtain 71.4% true positives, 88.3% true negatives, 11.4% false positives and 28.6% false negatives. Conclusion: By applying a first trimester PE prediction model to low risk pregnancies derived from a Portuguese population, a significant proportion of patients would have been predicted as high risk. New larger studies are required to confirm the present findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The adjusted effect of long-chain polyunsaturated fatty acid (LCPUFA) intake during pregnancy on adiposity at birth of healthy full-term appropriate-for-gestational age neonates was evaluated. STUDY DESIGN: In a cross-sectional convenience sample of 100 mother and infant dyads, LCPUFA intake during pregnancy was assessed by food frequency questionnaire with nutrient intake calculated using Food Processor Plus. Linear regression models for neonatal body composition measurements, assessed by air displacement plethysmography and anthropometry, were adjusted for maternal LCPUFA intakes, energy and macronutrient intakes, prepregnancy body mass index and gestational weight gain. RESULT: Positive associations between maternal docosahexaenoic acid intake and ponderal index in male offspring (β=0.165; 95% confidence interval (CI): 0.031-0.299; P=0.017), and between n-6:n-3 LCPUFA ratio intake and fat mass (β=0.021; 95% CI: 0.002-0.041; P=0.034) and percentage of fat mass (β=0.636; 95% CI: 0.125-1.147; P=0.016) in female offspring were found. CONCLUSION: Using a reliable validated method to assess body composition, adjusted positive associations between maternal docosahexaenoic acid intake and birth size in male offspring and between n-6:n-3 LCPUFA ratio intake and adiposity in female offspring were found, suggesting that maternal LCPUFA intake strongly influences fetal body composition.