4 resultados para Unit Groups
Resumo:
The authors analyzed 704 transthoracic echocardiographic (TTE) examinations, performed routinely to all admitted patients to a general 16-bed Intensive Care Unit (ICU) during an 18-month period. Data acquisition and prevalence of abnormalities of cardiac structures and function were assessed, as well as the new, previously unknown severe diagnoses. A TTE was performed within the first 24 h of admission on 704 consecutive patients, with a mean age of 61.5+/-17.5 years, ICU stay of 10.6+/-17.1 days, APACHE II 22.6+/-8.9, and SAPS II 52.7+/-20.4. In four patients, TTE could not be performed. Left ventricular (LV) dimensions were quantified in 689 (97.8%) patients, and LV function in 670 (95.2%) patients. Cardiac output (CO) was determined in 610 (86.7%), and mitral E/A in 399 (85.9% of patients in sinus rhythm). Echocardiographic abnormalities were detected in 234 (33%) patients, the most common being left atrial (LA) enlargement (n=163), and LV dysfunction (n=132). Patients with these alterations were older (66+/-16.5 vs 58.1+/-17.4, p<0.001), presented a higher APACHE II score (24.4+/-8.7 vs 21.1+/-8.9, p<0.001), and had a higher mortality rate (40.1% vs 25.4%, p<0.001). Severe, previously unknown echocardiographic diagnoses were detected in 53 (7.5%) patients; the most frequent condition was severe LV dysfunction. Through a multivariate logistic regression analysis, it was determined that mortality was affected by tricuspid regurgitation (p=0.016, CI 1.007-1.016) and ICU stay (p<0.001, CI 1-1.019). We conclude that TTE can detect most cardiac structures in a general ICU. One-third of the patients studied presented cardiac structural or functional alterations and 7.5% severe previously unknown diagnoses.
Resumo:
OBJECTIVE: The objective of the study was to develop a model for estimating patient 28-day in-hospital mortality using 2 different statistical approaches. DESIGN: The study was designed to develop an outcome prediction model for 28-day in-hospital mortality using (a) logistic regression with random effects and (b) a multilevel Cox proportional hazards model. SETTING: The study involved 305 intensive care units (ICUs) from the basic Simplified Acute Physiology Score (SAPS) 3 cohort. PATIENTS AND PARTICIPANTS: Patients (n = 17138) were from the SAPS 3 database with follow-up data pertaining to the first 28 days in hospital after ICU admission. INTERVENTIONS: None. MEASUREMENTS AND RESULTS: The database was divided randomly into 5 roughly equal-sized parts (at the ICU level). It was thus possible to run the model-building procedure 5 times, each time taking four fifths of the sample as a development set and the remaining fifth as the validation set. At 28 days after ICU admission, 19.98% of the patients were still in the hospital. Because of the different sampling space and outcome variables, both models presented a better fit in this sample than did the SAPS 3 admission score calibrated to vital status at hospital discharge, both on the general population and in major subgroups. CONCLUSIONS: Both statistical methods can be used to model the 28-day in-hospital mortality better than the SAPS 3 admission model. However, because the logistic regression approach is specifically designed to forecast 28-day mortality, and given the high uncertainty associated with the assumption of the proportionality of risks in the Cox model, the logistic regression approach proved to be superior.
Resumo:
The objective was to validate Regulatory Sensory Processing Disorders’ criteria (DC:0-3R, 2005) using empirical data on the presence and severity of sensory modulation deficits and specific psychiatric symptoms in clinical samples. Sixty toddlers who attended a child mental health unit were diagnosed by a clinical team. The following two groups were created: toddlers with RSPD(N = 14) and those with ‘‘other diagnoses in Axis I/II of the DC:0-3R00(OD3R) (N = 46). Independently of the clinical process, parents completed the Infant Toddler Sensory Profile (as a checklist for sensory symptoms) and the Achenbach Behavior Checklist for ages 1/2–5 (CBCL 1/2–5). The scores from the two groups were compared. The results showed the following for the RSPD group: a higher number of affected sensory areas and patterns than in the OD3R group; a higher percentage of sensory deficits in specific sensory categories; and a higher severity of behavioral symptoms such as withdrawal, inattention, other externalizing problems and pervasive developmental problems in CBCL 1/2–5. The results confirmed our hypotheses by indicating a higher severity of sensory symptoms and identifying specific behavioral problems in children with RSPD. The results revealed convergent validity between the instruments and the diagnostic criteria for RSPD and supported the validity of RSPD as a unique diagnosis. The findings also suggested the importance of identifying sensory modulation deficits in order to develop an early intervention to enhance the sensory capacities of children who do not fully satisfy the criteria for some DSM-IV-TR disorders.
Resumo:
Background: In the haemodynamically unstable patient the method of treatment of acute renal failure is still largely controversial. The purpose of our study was to compare slow extended dialysis with continuous haemodiafiltration in the critical patient with indication for renal replacement therapy and haemodynamic instability. Patients and Methods: This is a cohort study comparing in 63 ventilated critical patients a 12 month period when only continuous haemodiafiltration was used (n=25) with an equal period of slow extended dialysis (n=38). Our primary objective was to evaluate the impact of the dialytic procedure on cardiovascular stability in those patients. As secondary aims we considered system coagulation/thrombosis and predictors of mortality. In the two groups we analysed the first session performed, the second session performed and the average of all the sessions performed in each patient. Results: In these patients, mortality in the intensive care unit was high (68% in the continuous haemodiafiltration group and 63% in the slow extended dialysis group). We did not find any association between the dialytic technique used and death; only the APACHE score was a predictor of death. Slow extended dialysis was a predictor of haemodynamic stability, a negative predictor of sessions that had to be interrupted for haemodynamic instability, and a predictor of achieving the volume removal initially sought. Slow extended dialysis was also associated with less coagulation of the system. Conclusions: Our data suggested that slow extended dialysis use was not inferior to continuous haemodiafiltration use in terms of cardiovascular tolerability.