15 resultados para Ultrassonografia doppler
Resumo:
INTRODUCTION: Adults with repaired tetralogy of Fallot (TOF) may be at risk for progressive right ventricular (RV) dilatation and dysfunction, which is commonly associated with arrhythmic events. In frequently volume-overloaded patients with congenital heart disease, tissue Doppler imaging (TDI) is particularly useful for assessing RV function. However, it is not known whether RV TDI can predict outcome in this population. OBJECTIVE: To evaluate whether RV TDI parameters are associated with supraventricular arrhythmic events in adults with repaired TOF. METHODS: We studied 40 consecutive patients with repaired TOF (mean age 35 +/- 11 years, 62% male) referred for routine echocardiographic exam between 2007 and 2008. The following echocardiographic measurements were obtained: left ventricular (LV) ejection fraction, LV end-systolic volume, LV end-diastolic volume, RV fractional area change, RV end-systolic area, RV end-diastolic area, left and right atrial volumes, mitral E and A velocities, RV myocardial performance index (Tei index), tricuspid annular plane systolic excursion (TAPSE), myocardial isovolumic acceleration (IVA), pulmonary regurgitation color flow area, TDI basal lateral, septal and RV lateral peak diastolic and systolic annular velocities (E' 1, A' 1, S' 1, E' s, A' s, S' s, E' rv, A' rv, S' rv), strain, strain rate and tissue tracking of the same segments. QRS duration on resting ECG, total duration of Bruce treadmill exercise stress test and presence of exercise-induced arrhythmias were also analyzed. The patients were subsequently divided into two groups: Group 1--12 patients with previous documented supraventricular arrhythmias (atrial tachycardia, fibrillation or flutter) and Group 2 (control group)--28 patients with no previous arrhythmic events. Univariate and multivariate analysis was used to assess the statistical association between the studied parameters and arrhythmic events. RESULTS: Patients with previous events were older (41 +/- 14 vs. 31 +/- 6 years, p = 0.005), had wider QRS (173 +/- 20 vs. 140 +/- 32 ms, p = 0.01) and lower maximum heart rate on treadmill stress testing (69 +/- 35 vs. 92 +/- 9%, p = 0.03). All patients were in NYHA class I or II. Clinical characteristics including age at corrective surgery, previous palliative surgery and residual defects did not differ significantly between the two groups. Left and right cardiac chamber dimensions and ventricular and valvular function as evaluated by conventional Doppler parameters were also not significantly different. Right ventricular strain and strain rate were similar between the groups. However, right ventricular myocardial TDI systolic (Sa: 5.4+2 vs. 8.5 +/- 3, p = 0.004) and diastolic indices and velocities (Ea, Aa, septal E/Ea, and RV free wall tissue tracking) were significantly reduced in patients with arrhythmias compared to the control group. Multivariate linear regression analysis identified RV early diastolic velocity as the sole variable independently associated with arrhythmic history (RV Ea: 4.5 +/- 1 vs. 6.7 +/- 2 cm/s, p = 0.01). A cut-off for RV Ea of < 6.1 cm/s identified patients in the arrhythmic group with 86% sensitivity and 59% specificity (AUC = 0.8). CONCLUSIONS: Our results suggest that TDI may detect RV dysfunction in patients with apparently normal function as assessed by conventional echocardiographic parameters. Reduction in RV early diastolic velocity appears to be an early abnormality and is associated with occurrence of arrhythmic events. TDI may be useful in risk stratification of patients with repaired tetralogy of Fallot.
Resumo:
A manutenção de uma adequada pressão de perfusão cerebral é essencial para a prevenção de isquémia cerebral. Flutuações fisiológicas da pressão arterial a montante são compensadas localmente pela autoregulação cerebral. A reserva vascular cerebral necessária à eficácia desta autoregulação pode ser determinada medindo as modificações no fluxo sanguíneo cerebral em resposta a estímulos vasodilatadores. O Doppler Transcraneano tem sido usado para a determinação da velocidade do fluxo sanguíneo cerebral modificada por esses estímulos. Descrevemos um método de análise da capacidade de reserva da circulação cerebral pelo Doppler Transcraneano sob efeito do CO2. Este método pode ser útil para a caracterização das alterações hemodinâmicas que ocorrem em vários tipos de doença isquémica cerebral.
Resumo:
A Via Verde do Acidente Vascular Cerebral (AVC) tem como objectivo o tratamento rápido dos doentes com AVC isquémico com terapêuticas de repermeabilização, a fim de diminuir o grau de incapacidade por sequelas neurológicas Existem, contudo, critérios rígidos de selecção dos candidatos que beneficiam de terapêuticas de fase aguda o que origina a exclusão de um grande número de doentes. Estes doentes devem realizar de forma célere um estudo neurovascular de forma a permitir uma estratificação de risco e uma orientação terapêutica adequada. No nosso Centro, este estudo neurovascular tem sido feito frequentemente no Serviço de Urgência. Apresentação e discussão do resultado dos exames neurovasculares, neste caso Exame Ultrassonográfico dos Grandes Vasos do Pescoço (ECODVP), realizado no Serviço de Urgência do Hospital de São José - Centro Hospitalar Lisboa Central, pelo Laboratório de Neurossonologia – Unidade Cerebrovascular, durante o ano de 2011. Análise retrospectiva de todos os doentes que realizaram ECODVP no Serviço de Urgência durante o período de 1 de Janeiro a 31 de Dezembro de 2011. Estes exames foram executados com recurso a um Ecógrafo Toshiba com sonda linear (7-14MHz). Os exames foram classificados em “Normal”, “Estenose Carotídea ou Vertebral > 50%”, “Trombo na Carótida Interna”, “Dissecção Carotídea ou vertebral”, “Oclusão Alta da Carótida Interna” e “Oclusão Proximal da Carótida Interna”. Foram avaliados 164 indivíduos (93 sexo masculino e 71 sexo feminino) com uma média de idades = 64,40 anos. Dos 164 indivíduos avaliados foram documentados 134 exames Normais correspondendo a 82% do total de exames. Dos restantes 18%, 30 tinham as seguintes alterações: Estenoses Carotídeas ou Vertebrais (> 50%): 17; Trombo Carotídeo: 2; Dissecções Carotídeas ou Vertebrais: 3; Oclusão Alta da Carótida Interna: 6; Oclusão Proximal da Carótida Interna: 2. A realização de exames Neurovasculares no Serviço de Urgência do Hospital de São José traduz um serviço de qualidade, permitindo redireccionar e encaminhar os doentes, adequando as devidas medidas diagnósticas e terapêuticas a instituir.
Resumo:
Em contexto de urgência o Cardiopneumologista desempenha um papel fundamental pela realização de diversos meios complementares de diagnóstico e terapêutica. Entre estes surge o Ecodoppler Neurovascular, técnica ultrassonográfica inócua, não invasiva, de fácil aplicação, que permite a obtenção de um elevado número de achados clínicos, essenciais ao encaminhamento do doente em qualquer contexto clínico. Assim este exame demonstra a sua aplicabilidade essencialmente em pacientes neurocríticos ou outros com suspeita e/ou diagnóstico de Acidente Isquémico Transitório, Acidente Vascular Cerebral (AVC), Hemorragia Subaracnoideia, Anemia das Células Falciformes e Hidrocefalia. Ainda em contexto de urgência o Ecodoppler Neurovascular assume real importância na orientação e tratamento de doentes da Via Verde AVC, uma das principais e preocupantes causas de morbilidade e mortalidade em todo o Mundo. A realização destes exames na prática hospitalar, neste conjunto de patologias, permite uma correcta e precoce orientação terapêutica, com consequente rentabilização de custos e melhorias na qualidade do tratamento. No entanto, é de referir que esta abordagem só é possível de acordo com a existência de equipas multidisciplinares de elevada relevância especialmente em contexto de urgência, local específico de encaminhamento de pacientes urgentes ou não urgentes. A título de conclusão a realização do exame Ecodoppler Neurovascular no Serviço de Urgência traduz um serviço de qualidade, permitindo redireccionar e encaminhar os doentes, adequando as devidas medidas diagnósticas e terapêuticas a instituir.
Resumo:
BACKGROUND: Atherosclerotic carotid disease represents approximately 20% of the causes of ischemic stroke. Effective treatment options, such as endovascular or surgical revascularization procedures, are available. Doppler Ultrasound (DUS) is a non-invasive, inexpensive, routine exam used to evaluate the presence of internal carotid artery (ICA) stenosis. We retrospectively analysed the prevalence of severe atherosclerotic carotid disease in a population of patients with acute ischemic stroke/transitory ischemic attacks (TIAs), and the role of DUS in the detection of ICA stenosis and treatment decisions in these patients. METHODS: A total of 318 patients with ischemic stroke or TIAs was admitted to our stroke unit, and 260 patients were studied by DUS. ICA stenosis was evaluated by DUS according to peak systolic velocity. All DUS exams were performed by the same operator. ICA stenosis was further assessed in 43 patients by digital subtraction angiography (DSA) using NASCET criteria. RESULTS: Of the total 318 patients, 260 (82%) had DUS evaluation. Of the total 520 ICAs studied by DUS, degrees of ICA stenosis were: 0-29% n= 438 (84%); 30-49% n= 8 (2%); 50-69% n= 27 (5%); 70-89% n= 15 (3%); 90-99% n= 20 (4%); oclusão n= 14 (2%). Of the total 260 patients studied, 43 (16.5%) underwent DSA. Sensibility and specificity of DUS in the diagnosis of carotid stenosis over 70% were, respectively, 91% e 84%. Of the total 31 patients with significant carotid stenosis (70-99%), 23 (74%) underwent subsequent carotid revascularization procedures. DISCUSSION: DUS is an important screening test in our stroke unit, justifying its use as a routine exam for all patients with ischemic stroke/TIAs. Moreover, our results show the relevance of severe carotid disease in a population with acute ischemic stroke/TIAs (16.5%), with a total of 9% of patients being submitted to carotid revascularization procedures.
Resumo:
Previous studies have shown that a ratio of early transmitral flow velocity to early diastolic velocity of the mitral annulus (E/E') of > 15, obtained by tissue Doppler imaging (TDI), correlates with left ventricular filling pressure. OBJECTIVE: The aim of our study was to assess whether E/E' provides prognostic information in patients with dilated cardiomyopathy. METHODS: We studied 33 patients with dilated cardiomyopathy and mean ejection fraction of 31%. All the patients underwent routine two-dimensional and Doppler echocardiographic examination and TDI to determine early peak velocity of the mitral annulus. Pro-B-type natriuretic peptide (pro-BNP) and peak oxygen consumption (VO2max) were also measured. Patients were divided into two groups according to the value of E/E': Group I (n = 15 patients) with E/E' > or = 15 and Group II (n = 18 patients) with E/E' < 15. Patients were followed for 12+/-4 months; new hospital admission due to heart failure, heart transplantation and death were considered as cardiac events. RESULTS: There were significant differences between the two groups in conventional two-dimensional echocardiographic measurements (dimensions and ejection fraction) and Doppler parameters (mitral inflow). With regard to mitral annular velocities obtained by TDI at two different points (septum and lateral wall), the E', A' and S' velocities differed significantly between the two groups, with lower velocities in Group I. Systolic velocity measured in the lateral portion of the mitral annulus showed the most significant difference: Group I - 4.46 cm/sec versus Group II - 7.19 cm/sec, p < 0.00001. Pro-BNP was 5622 pg/ml in Group I, and 1254 pg/ml in Group II, p = 0.004. VO2 max was significantly different between the two groups: Group I - 17.6 ml/kg/min versus Group II - 22.8 ml/kg/min, p = 0.004. During follow-up, events were more common in Group I, with 9 patients (60%) having events, while in Group II, the event rate was 11.1% (2 patients), p = 0.004. CONCLUSION: The ratio of early transmitral flow velocity to early diastolic velocity of the mitral annulus is a powerful predictor of clinical outcome. Lower velocities of mitral annulus on TDI are expected in patients with E/E' > or = 15. Systolic velocities of under 5 cm/sec measured in the lateral portion of the mitral annulus appeared to be strongly related to prognosis.
Resumo:
INTRODUCTION: The significant risk of sudden arrhythmic death in patients with congestive heart failure and electromechanical ventricular dyssynchrony has led to increased use of combined cardiac resynchronization therapy defibrillator (CRT-D) devices. OBJECTIVES: To evaluate the echocardiographic variables in patients undergoing CRT-D that predict the occurrence of appropriate therapies (AT) for ventricular tachyarrhythmia. METHODS: We analyzed 38 consecutive patients (mean age 60 +/- 12 years, 63% male) with echocardiographic evaluation before and 6 months after CRT-D implantation. Patients with AT were identified in a mean follow-up of 471 +/- 323 days. A standard echocardiographic study was performed including tissue Doppler imaging (TDI). Responders were defined as patients with improvement in NYHA class of < or = 1 in the first six months, and reverse remodeling as a decrease in left ventricular end-systolic volume of < or = 15% and/or an increase in left ventricular ejection fraction of > 25%. RESULTS: The responder rate was 74%, and the reverse remodeling rate was 55%. AT occurred in 21% of patients, who presented with greater left ventricular end-diastolic internal diameter (LVEDD) before implantation (86 +/- 8 vs. 76 +/- 11 mm, p = 0.03) and at 6 months (81 +/- 8 vs. 72 +/- 14 mm, p = 0.08), and increased left ventricular end-systolic internal diameter (66 +/- 14 vs. 56 +/- 14 mm, p = 0.03) and lower ejection fraction (24 +/- 6 vs. 34 +/- 14%, p = 0.08) at 6 months. In the group with AT, the responder rate was lower (38 vs. 83%, p = 0.03), without significant differences in reverse remodeling (38% for the AT group vs. 60%, p = 0.426) or in the other variables. By univariate analysis, predictors of AT were LVEDD before implantation and E' after implantation. Age, gender, ischemic etiology, use of antiarrhythmic drugs, reverse remodeling and the other echocardiographic parameters did not predict AT. In multivariate logistic regression analysis, both LVEDD before implantation (OR 1.24, 95% CI 1.04-1.48, p = 0.019) and postimplantation E' (OR 0.27, 95% CI 0.09-0.76, p = 0.014) remained as independent predictors of AT. CONCLUSIONS: In patients undergoing CRT-D, episodes of ventricular tachyarrhythmia occur with high incidence, independently of echocardiographic response, with LVEDD before implantation and E' after implantation as the only independent predictors of AT in the medium-term. These results highlight the importance of combined devices with defibrillation capability.
Resumo:
Recentemente, surgiram alguns trabalhos que ressaltaram a importância do cálculo do volume da aurícula esquerda (VAE) como um marcador de eventos cardíacos adversos. Foi objectivo deste estudo avaliar a importância prognóstica deste parâmetro em doentes (dts) com deficiente função ventricular esquerda e correlacioná-lo com outros parâmetros clássicos de prognóstico – consumo de O2 (VO2 max) e pro-BNP (pBNP). Métodos: Analisou-se o volume da aurícula esquerda (VAE) por método de Simpson, numa população de 35 dts com cardiopatia dilatada (idiopática e isquémica) com fracção de ejecção (FE) 31±9,6% doentes (dts) eram de sexo masculino e a média de idades foi de 50,5±10,5 anos. Toda a população efectuou estudos de ecocardiografia convencional (incluindo avaliação por M-mode, bidimensional e Doppler), prova cardiorespiratória (VO2max) e doseamento de pro-BNP. O tempo médio de seguimento foi de 24 ± 4 meses, tendo-se considerado como eventos cardíacos (EC): internamento por insuficiência cardíaca, transplante e morte. Resultados: Dos parâmetros da ecocardiografia - o diâmetro da AE foi de 46,6±5,7mm, as dimensões do VE em diástole – 73,5±10mm e em sístole -58,9±11mm, a média da fracção de ejecção foi de 31±9,6%, o VAE foi de 78,6±33 ml, os volumes do VE foram de 214±82ml em diástole e de 153±75ml em sístole, 15 dts tinham padrão restritivo de enchimento ventricular (E/A>2), a média da área (Doppler cor) da insuficiência mitral foi de 4±3,3cm2, 14 dts tinham E/E’>15. O VO2 max médio foi de 20±5,8ml/kg/min e o pro-BNP de 3146±4629pg/mL. Para além da correlação de outros parâmetros clássicos ecocardiográficos com o prognóstico (volumes VE, FE e E/E’), o VAE e o volume indexado da AE (VAE/SC) mostraram uma correlação com o prognóstico (EC) com r=0,4 (p=0,02) que não se verificou para o diâmetro da AE (p=ns). Em relação à tolerância ao esforço, houve uma correlação inversa entre o diâmetro, o volume e o volume indexado da AE e o VO2max, com maior significado estatístico para o VAE e VAE/SC com r=-0,48, p=0,008. Quanto ao pro-BNP, quer o diâmetro, quer o VAE (ou volume indexado) tiverem o mesmo nível de significado estatístico (r=0,43; p=0,02). O valor predictivo de eventos (curvas ROC) para o VAE foi de 70ml e de 37ml/m2 para o VAE/m2. Conclusão: O volume da aurícula esquerda/volume indexado é um parâmetro ecocardiográfico com significado prognóstico em dts com deficiente função ventricular esquerda, correlacionando-se com a tolerância ao esforço e pro-BNP.
Resumo:
"Cor triatriatum dexter" (CTD) is an unusual cyanotic cardiac defect in which the right atrium is subdivided into two distinct chambers due to the persistence of the "sinus venosus" valve. Two patients with CTD ho were evaluated and treatment in 1979 and 1992 are described: the first one, had total anomalous pulmonary venous return to the coronary sinus or "cor triatriatum sinister" as preoperative diagnosis based on M-mode echocardiographic findings. The presence of a membrane inside the right atrium was suspected on cineangiogram. The other one had a preoperative diagnosis of CTD. Anatomic relationships and physiological effects were established by two dimensional and Doppler ultrasonography and confirmed at cardiac catheterization and surgery. High resolution two dimensional echocardiography coupled with Doppler ultrasonography has a definite role in the study of this heart defect.
Resumo:
Introdução: A Pressão Venosa Central (PVC), é um importante parâmetro hemodinâmico, reflectindo o estado de hidratação. Embora existam estudos de cálculo não invasivo da PVC por ecocardiografia, não está descrito um método de quantificação exacta da mesma. Objectivos: Analisando diversos parâmetros ecocardiográficos, os autores propõem uma fórmula de cálculo da PVC que mostra boa correlação estatística com a PVC medida de forma invasiva. Material e Métodos: O estudo foi efectuado em 45 doentes internados na UCI, 32 em ritmo sinusal e 13 em fibrilhação auricular, 32 dos quais submetidos a ventilação mecânica. Fizeram-se simultaneamente medições invasivas da PVC e o estudo ecocardiográfico transtorácico com Doppler. Os métodos estatísticos utilizados foram a correlação bivariada e análise de variâncias. Resultados: Foram encontrados diversos parâmetros ecocardiográficos que mostram boa correlação com o valor da PVC medida. A estes foram aplicados coeficientes estandardizados e obteve-se a seguinte fórmula de cálculo da PVC: (desaceleração E tricúspide) x 0,11 + (gradiente VD/AD) x 0,16 - (variação da VCI). Conclusão: Acrescenta-se mais um elemento de avaliação hemodinâmica não invasiva quantificando um parâmetro até agora só avaliado de forma aproximada por esta abordagem.
As Alterações do Doppler Cardíaco Perante Modificação da Volémia em Cuidados Intensivos Polivalentes
Resumo:
Num grupo de 64 doentes de uma Unidade de Cuidados Intensivos, 24 dos quais submetidos a ventilação mecânica, foi determinada a influência da modificação da volémia nas características do Doppler cardíaco, através da negativização do balanço hídrico e correspondente modificação da pressão venosa central. Com a modificação da volémia, a relação E/A do fluxo transvalvular mitral mostrou uma tendência para reduzir, o tempo de desaceleração da onda E mitral para diminuir, o tempo de relaxamento isovolumétrico para aumentar, e a veia cava inferior reduziu o seu diâmetro expiratório e aumentou o valor do colapso inspiratório. Não se observou uma correlação significativa entre os valores das variáveis estudadas e a modificação da volémia, inclusivamente entre a pressão venosa central e o balanço hídrico. A modificação da volémia em doentes críticos modifica as características de determinados parâmetros de ecocardiografia- -Doppler, mas não é possível predizer a magnitude dessa variação.
Resumo:
Objectivo: Estabelecer valores de referência da robustez óssea nos primeiros dias de vida, em recém-nascidos de termo e pré-termo adequados para a idade de gestação nascidos em Portugal. Métodos: Foi medida a velocidade do som (VdS) (m/s) por ultrassonografia quantitativa, numa amostra sistemática de recém-nascidos adequados para a idade de gestação, de termo e pré-termo, respectivamente nos primeiros dois e cinco dias após o nascimento. Foi avaliada a homogeneidade de valores entre géneros e entre grupos de idade de gestação. Resultados: A amostra constou de 158 recém-nascidos, 34 de termo e 124 pré-termo (idade de gestação entre 26 a 41 semanas), com peso de nascimento de 595 g a 4195 g, 84 do sexo masculino (53,2%) e 20 gémeos (10,8%). A média da VdS aumenta significativamente com a idade de gestação. São providenciados valores de referência da VdS para os percentis 10, 25, 50, 75 e 90, para grupos de idade de gestação, sem distinção para o género. Conclusão: São disponibilizados valores de referência de VdS nos primeiros dias de vida, de recém-nascidos adequados para a idade de gestação, de termo e pré-termo, nascidos em Portugal. Estes valores reflectem a robustez óssea intrauterina e servem de referência basal para estudos evolutivos realizados em Portugal.
Resumo:
Objectivo: Avaliar a acuidade da angiografia de subtracção digital (ASD) no diagnóstico morfológico da conexão venosa pulmonar anómala (CVPA) em crianças. Concepção do estudo: Estudo prospectivo de doentes consecutivos entre Janeiro de 1989 e Julho de 1992. Tipo de Atendimento: Serviço de Cardiologia Pediátrica de um Hospital Central. População: Vinte e quatro doentes com CVPA. Métodos: Todos os doentes fizeram avaliação clínica e ecocardiográfica completa (modo M, bidimensional e Doppler) antes da realização do exame hemodinâmico. Em todos os casos se fizeram, de modo sistemático, injecções selectivas de contraste de baixa osmolaridade (0,5-1 ml/kg; dose total <6 mi/kg) no tronco e ramos da artéria pulmonar com registo em angiografia com subtracção digital (ASD). As imagens colhidas foram trabalhadas, selecciona das e armazenadas em video-cassetes e películas fotográficas (câmara multiformato). Resultados: Dezasseis doentes tinham CVPA total (CVPAT): onze à veia cava superior (VCS), dois ao seio coronário e três infradiafragmáticos (dois à veia cava inferior (VCI) e um à veia porta). Oito crianças tinham CVPA parcial (CVPAP): três à VCS, uma à aurícula direita (AD), três à VCI (síndroma da cimitarra) e num caso a CVPA era mista. Em oito doentes (seis com CVPAT e dois com CVPAP), a ASD contribuiu significativamente para o diagnóstico final tendo completado ou corrigido a informação obtida por ecocardiografia. Nos dezoito doentes submetidos a cirurgia cardíaca foi confirmado o diagnóstico obtido por ASD. Conclusões: A ASD é um método muito útil para o diagnóstico anatómico de doentes com CVPA. Na nossa experiência foi particularmente informativa a análise de registos em «video». A ASD está indicada nos casos em que os achados clínicos e ecocardiográficos não sejam típicos.
Resumo:
Apresenta-se um caso clínico de dissecção da aorta abdominal - tipo B - diagnosticada por eco-Doppler e tomografia axial computorizada (TC). Discute-se o interesse do eco-Doppler no diagnóstico de dissecção da aorta abdominal e na avaliação do envolvimento arterial visceral. É ainda um método útil no follow-up dos doentes com terapêutica conservadora.
Resumo:
PURPOSE: To determine the correlation between ocular blood flow velocities and ocular pulse amplitude (OPA) in glaucoma patients using colour Doppler imaging (CDI) waveform analysis. METHOD: A prospective, observer-masked, case-control study was performed. OPA and blood flow variables from central retinal artery and vein (CRA, CRV), nasal and temporal short posterior ciliary arteries (NPCA, TPCA) and ophthalmic artery (OA) were obtained through dynamic contour tonometry and CDI, respectively. Univariate and multiple regression analyses were performed to explore the correlations between OPA and retrobulbar CDI waveform and systemic cardiovascular parameters (blood pressure, blood pressure amplitude, mean ocular perfusion pressure and peripheral pulse). RESULTS: One hundred and ninety-two patients were included [healthy controls: 55; primary open-angle glaucoma (POAG): 74; normal-tension glaucoma (NTG): 63]. OPA was statistically different between groups (Healthy: 3.17 ± 1.2 mmHg; NTG: 2.58 ± 1.2 mmHg; POAG: 2.60 ± 1.1 mmHg; p < 0.01), but not between the glaucoma groups (p = 0.60). Multiple regression models to explain OPA variance were made for each cohort (healthy: p < 0.001, r = 0.605; NTG: p = 0.003, r = 0.372; POAG: p < 0.001, r = 0.412). OPA was independently associated with retrobulbar CDI parameters in the healthy subjects and POAG patients (healthy CRV resistance index: β = 3.37, CI: 0.16-6.59; healthy NPCA mean systolic/diastolic velocity ratio: β = 1.34, CI: 0.52-2.15; POAG TPCA mean systolic velocity: β = 0.14, CI 0.05-0.23). OPA in the NTG group was associated with diastolic blood pressure and pulse rate (β = -0.04, CI: -0.06 to -0.01; β = -0.04, CI: -0.06 to -0.001, respectively). CONCLUSIONS: Vascular-related models provide a better explanation to OPA variance in healthy individuals than in glaucoma patients. The variables that influence OPA seem to be different in healthy, POAG and NTG patients.