7 resultados para Toric implantable collamer lens


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multifocal intraocular lenses (MF IOLs) have concentric optical zones with different dioptric power, enabling patients to have good visual acuity at multiple focal points. However, several optical limitations have been attributed to this particular design. The purpose of this study is to access the effect of MF IOLs design on the accuracy of retinal optical coherence tomography (OCT). Cross-sectional study conducted at the Refractive Surgery Department of Central Lisbon Hospital Center. Twenty-three eyes of 15 patients with a diffractive MF IOL and 27 eyes of 15 patients with an aspheric monofocal IOL were included in this study. All patients underwent OCT macular scans using Heidelberg Spectralis®. Macular thickness and volume values and image quality (Q factor) were compared between the two groups. There were no statistically significant differences between both groups regarding macular thickness or volume measurements. Retinal OCT image quality was significantly lower in the MF IOL group (p < 0.01). MF IOLs are associated with a significant decrease in OCT image quality. However, this fact does not seem to compromise the accuracy of spectral domain OCT retinal measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O aumento significativo registado nas implantações de dispositivos cardíacos, sobretudo como consequência dos benefícios demonstrados com a utilização de cardioversoresdesfibrilhadores e sistemas de ressincronização cardíaca na redução da mortalidade, trouxe para a prática clínica hospitalar o problema da gestão de recursos para responder ao crescimento exponencial do número de doentes em consultas regulares de seguimento especializado. A era das tecnologias da comunicação permitiu desenvolver sistemas de monitorização à distância, que são hoje uma realidade em franca expansão na Europa e nos Estados Unidos, com diversas vantagens e níveis de eficácia e segurança bem documentados. A sua utilização tem permitido obter um elevado grau de satisfação para o doente e médico, reduzindo o número de visitas hospitalares e os custos inerentes ao seguimento desta população. Os resultados dos diferentes estudos têm mostrado elevada capacidade na deteção mais precoce de problemas clínicos, arrítmicos ou de descompensação da insuficiência cardíaca, e de anomalias no funcionamento do dispositivo implantado. Apesar da experiência favorável com o recurso a esta metodologia de follow-up, são necessários estudos para avaliar o seu impacto clínico a longo prazo, em comparação com as consultas convencionais, bem como a introdução e adaptação da legislação referente a este tipo de evolução tecnológica aplicada à saúde. No presente artigo, revimos os aspetos técnicos e a evidência recente da relevância clínica da monitorização à distância em portadores de dispositivos cardíacos implantados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Sulfite oxidase deficiency (SOD) is an autosomal recessive inherited disease usually presenting in the neonatal period with severe neurological symptoms including seizures, often refractory to anticonvulsant therapy, and a rapidly progressive encephalopathy resembling neonatal hypoxic ischemia, with premature death. Most patients develop dislocated ocular lenses. Later or milder presentations of SOD are being reported with increasing frequency. These presentations include neurological regression with loss of previously acquired milestones or movement disorders. Case report: We report a four years old girl presenting with intermittent ataxia and uncoordinated limb movements. A similar episode of ataxia had occurred previously, one year before, with complete neurologic recovery and normal developmental milestones. Bilateral lens dislocation had been recently diagnosed. Cranial MRI demonstrated bilateral globus pallidus enhancement. Low homocysteine was found in plasma and SulfitestR was positive. Further investigations led to confirmation of isolated sulfite oxidase deficiency with no enzyme activity detected on skin fibroblasts culture. Discussion: This case illustrates the clinical variability of SOD and it is not only atypical but also seems to be the mildest form described so far. The association of ectopia lentis with a movement disorder, even without psychomotor regression, should prompt us to look for this diagnosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Based on a survey sent to Portuguese centers that perform diagnostic and interventional electrophysiology and/or implantable cardioverter-defibrillator (ICD) implantations, the authors analyze the number and type of procedures performed during 2012 and compare these data with previous years. In 2012, a total of 2561 diagnostic electrophysiologic studies were performed, which were followed by ablation in 2017 cases, representing a steady situation compared with the previous year. There was a 12% increase in the number of ablation procedures for atrial fibrillation, making it for the first time the most frequent indication for ablation, overtaking atrioventricular nodal reentrant tachycardia. The total number of first ICD implantations was 1048 (around 100 per million population), of which 375 were cardiac resynchronization devices (BiV ICDs). This represents a slight decrease (3.3%) in the total number of new implants, with an increase of 10% in the number of BiV ICDs compared to the previous year. However, there was a considerable increase in the number of ICD generator replacements, resulting in an overall increase of 3.5% in implantations performed in 2012. Some comments are made regarding developments in this activity and its current status, and on some factors that may influence the dynamics of this area of interventional cardiology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the case of a 52-year-old man who presented to our emergency department (ED) after three episodes of syncope in the seven hours before admission. During his stay in the ED he had recurrent ventricular tachycardia (VT) requiring external electrical cardioversion. A 12-lead electrocardiogram (ECG) showed a short QT (SQT) interval (270 ms, QTc 327 ms), with frequent R-on-T extrasystoles triggering sustained polymorphic VT. After exclusion of other precipitating causes, the patient was diagnosed as having SQT syndrome (SQTS) according to the Gollob criteria. To our knowledge, this is the first known documentation of an SQT-caused arrhythmic episode on a 12-lead ECG, as well as the first reported case of SQTS in Portugal. The patient received an implantable cardioverter-defibrillator and was discharged. At a follow-up assessment 14 months later he was symptom-free, interrogation of the device showed no arrhythmic events, and the ECG showed a QT interval of 320 ms (QTc 347 ms).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Primary angle closure occurs as a result of crowded anterior segment anatomy, causing appositional contact between the peripheral iris and trabecular meshwork, thereby obstructing aqueous outflow. Several studies highlight the role of the crystalline lens in its pathogenesis. The objective of this work is to compare the long-term efficacy of phacoemulsification versus laser peripheral iridotomy (LPI) in the management of chronic primary angle closure (CPAC). Prospective case-control study with 30 eyes of 30 patients randomly divided in two groups: 15 eyes in the LPI group and 15 eyes in the IOL group. Patients in the LPI group underwent LPI using argon and Nd:YAG laser. Patients in the IOL group underwent phacoemulsification with posterior chamber intraocular lens (IOL) implantation. Examinations before and after the procedure included gonioscopy, Goldmann applanation tonometry, and anterior chamber evaluation using the Pentacam rotating Scheimpflug camera. The mean follow-up time was 31.13 ± 4.97 months. There was a statistically significant reduction in the intraocular pressure (IOP) and number of anti-glaucoma medications (p < 0.01) only in the IOL group. Anterior chamber depth, angle, and volume were all higher in the IOL group (p < 0.01) at the end of the follow-up period. Phacoemulsification with posterior chamber IOL implantation results in a higher anterior chamber depth, angle, and volume, when compared to LPI. Consequently, phacoemulsification has greater efficacy in lowering IOP and preventing its long-term increase in patients with CPAC and cataract.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diabetic macular oedema (DMO) is a leading cause of vision loss in the working-age population worldwide. Corticosteroid drugs have been demonstrated to inhibit the expression of both the vascular endothelial growth factor (VEGF) gene and other anti-inflammatory mediators, such as prostaglandins. Triamcinolone, fluocinolone and dexamethasone are the main steroids that have been studied for the treatment of macular oedema. Over the last few years, several studies have suggested an important role for dexamethasone in the management of DMO. The dexamethasone intravitreal implant (DEX implant) (Ozurdex®; Allergan, Inc., Irvine, CA) is a novel approach approved by the US Food and Drug Administration (FDA) and by the EU for the intravitreal treatment of macular oedema after branch or central retinal vein occlusion, and for the treatment of non-infectious uveitis affecting the posterior segment of the eye. We reviewed manuscripts that had investigated the pharmacokinetics, efficacy and safety of the DEX implant regarding DMO treatment.