3 resultados para The Critical Incident Technique
Resumo:
Background: In the haemodynamically unstable patient the method of treatment of acute renal failure is still largely controversial. The purpose of our study was to compare slow extended dialysis with continuous haemodiafiltration in the critical patient with indication for renal replacement therapy and haemodynamic instability. Patients and Methods: This is a cohort study comparing in 63 ventilated critical patients a 12 month period when only continuous haemodiafiltration was used (n=25) with an equal period of slow extended dialysis (n=38). Our primary objective was to evaluate the impact of the dialytic procedure on cardiovascular stability in those patients. As secondary aims we considered system coagulation/thrombosis and predictors of mortality. In the two groups we analysed the first session performed, the second session performed and the average of all the sessions performed in each patient. Results: In these patients, mortality in the intensive care unit was high (68% in the continuous haemodiafiltration group and 63% in the slow extended dialysis group). We did not find any association between the dialytic technique used and death; only the APACHE score was a predictor of death. Slow extended dialysis was a predictor of haemodynamic stability, a negative predictor of sessions that had to be interrupted for haemodynamic instability, and a predictor of achieving the volume removal initially sought. Slow extended dialysis was also associated with less coagulation of the system. Conclusions: Our data suggested that slow extended dialysis use was not inferior to continuous haemodiafiltration use in terms of cardiovascular tolerability.
Resumo:
PURPOSE: The Genous™ stent (GS) is designed to accelerate endothelization, which is potentially useful in the pro-thrombotic environment of ST-elevation acute myocardial infarction (STEMI). We aimed to evaluate the safety and effectiveness of the GS in the first year following primary percutaneous coronary intervention (PCI) and to compare our results with the few previously published studies. METHODS AND MATERIALS: All patients admitted to a single center due to STEMI that underwent primary PCI using exclusively GS, between May 2006 and January 2012, were enrolled. The primary study endpoints were major adverse cardiac events (MACEs), defined as the composite of cardiac death, acute myocardial infarction and target vessel revascularization, at one and 12months. RESULTS: In the cohort of 109 patients (73.4% male, 59 ±12years), 24.8% were diabetic. PCI was performed in 116 lesions with angiographic success in 99.1%, using 148 GS with median diameter of 3.00mm (2.50-4.00) and median length of 15mm (9-33). Cumulative MACEs were 2.8% at one month and 6.4% at 12months. Three stent thromboses (2.8%), all subacute, and one stent restenosis (0.9%) occurred. These accounted for the four target vessel revascularizations (3.7%). At 12months, 33.9% of patients were not on dual antiplatelet therapy. CONCLUSIONS: GS was safe and effective in the first year following primary PCI in STEMI, with an apparently safer profile comparing with the previously published data. SUMMARY: We report the safety and effectiveness of the Genous™ stent (GS) in the first year following primary percutaneous coronary intervention in ST-elevation acute myocardial infarction. A comprehensive review of the few studies that have been published on this subject was included and some suggest a less safe profile of the GS. Our results and the critical review included may add information and reinforce the safety and effectiveness of the GS in ST-elevation in acute myocardial infarction.
Resumo:
Objective: The epilepsies associated with the tuberous sclerosis complex (TSC) are very often refractory to medical therapy. Surgery for epilepsy is an effective alternative when the critical link between the localization of seizure onset in the scalp and a particular cortical tuber can be established. In this study we perform analysis of ictal and interictal EEG to improve such link. Methods: The ictal and interictal recordings of four patients with TSC undergoing surgery for epilepsy were submitted to independent component analysis (ICA), followed by source analysis, using the sLORETA algorithm. The localizations obtained for the ictal EEG and for the average interictal spikes were compared. Results: The ICA of ictal EEG produced consistent results in different events, and there was good agreement with the tubers that were successfully removed in three of the four patients (one patient refused surgery). In some patients there was a large discrepancy between the localization of ictal and interictal sources. The interictal activity produced more widespread source localizations. Conclusions: The use of ICA of ictal EEG followed by the use of source analysis methods in four cases of epilepsy and TSC was able to localize the epileptic generators very near the lesions successfully removed in surgery for epilepsy. Significance: The ICA of ictal EEG events may be a useful add-on to the tools used to establish the connection between epileptic scalp activity and the cortical tubers originating it, in patients with TSC considered for surgery of epilepsy.