3 resultados para Surrogate Data
Resumo:
A pilot study aimed to introduce intraoperative monitoring of liver surgery using transoesophageal echocardiography (TEE) is described. A set of TEE measurements was established as a protocol, consisting of left atrial (LA) dimension at the aortic valve plane; mitral velocity flow integral, calculation of stroke volume and cardiac output (CO); mitral annular plane systolic excursion; finally, right atrial area. A total of 165 measurements (on 21 patients) were performed, 31 occurring during hypotension. The conclusions reached were during acute blood loss LA dimension changed earlier than CVP, and, in one patient, a dynamic left ventricular (LV) obstruction was observed; in 3 patients a transient LV systolic dysfunction was documented. The comparison between 39 CO paired measurements obtained by TEE and PiCCO2 revealed a statistically significant correlation (P < 0.001, r = 0.83). In this pilot study TEE successfully answered the questions raised by the anesthesiologists. Larger cohort studies are needed to address this issue.
Resumo:
Introduction. Pulmonary arterial hypertension (PAH) is a rare disease that must be managed in specialized centers; therefore, the availability of epidemiological national data is critical. Methods. We conducted a prospective, observational, and multicenter registry with a joint collaboration from five centers from Portugal and included adult incident patients with PAH or chronic thromboembolic pulmonary hypertension (CTEPH). Results. Of the 79 patients enrolled in this study, 46 (58.2%) were classified as PAH and 33 patients (41.8%) as CTEPH. PAH patients had a mean age of 43.4 ± 16.4 years. Idiopathic PAH was the most common etiology (37%). At presentation, PAH patients had elevated right atrial pressure (RAP) (7.7 ± 5.9mmHg) and mean pulmonary vascular resistance (11.4 ± 6.5 Wood units), with a low cardiac index (2.7 ± 1.1 L⋅min−1 m−2); no patient was under selective pulmonary vasodilators; however, at follow-up, most patients were on single (50%), double (28%), or triple (9%) combination vasodilator therapy. One-year survival was 93.5%, similar to CTEPH patients (93.9%), that were older (60.0 ± 12.5 years) and had higher RAP (11.0 ± 5.2mmHg,
Resumo:
Poor ventilation at day care centres (DCCs) was already reported, although its effects on attending children are not clear. This study aimed to evaluate the association between wheezing in children and indoor CO2 (a ventilation surrogate marker) in DCC and to identify behaviours and building characteristics potentially related to CO2. In phase I, 45 DCCs from Lisbon and Oporto (Portugal) were selected through a proportional stratified random sampling. In phase II, 3 months later, 19 DCCs were further reassessed after cluster analysis for the greatest difference comparison. In both phases, children’s respiratory health was assessed by ISAAC-derived questionnaires. Indoor CO2 concentrations and building characteristics of the DCC were evaluated in both phases, using complementary methods. Mixed effect models were used to analyze the data. In phase I, which included 3,186 children (mean age 3.1±1.5 years), indoor CO2 concentration in the DCC rooms was associated with reported wheezing in the past 12months (27.5 %) (adjusted odds ratio (OR) for each increase of 200 ppm 1.04, 95 % CI 1:01 to 1:07). In phase II, the association in the subsample of 1,196 children seen in 19 out of the initial 45 DCCs was not significant (adjusted OR 1.02, 95 % CI 0.96 to 1.08). Indoor CO2 concentration was inversely associated with the practices of opening Windows and internal doors and with higher wind velocity. A positive trend was observed between CO2 and prevalence of reported asthma (4.7 %). Conclusion: Improved ventilation is needed to achieve a healthier indoor environment in DCC.