7 resultados para Scale monitoring
Resumo:
A pilot study aimed to introduce intraoperative monitoring of liver surgery using transoesophageal echocardiography (TEE) is described. A set of TEE measurements was established as a protocol, consisting of left atrial (LA) dimension at the aortic valve plane; mitral velocity flow integral, calculation of stroke volume and cardiac output (CO); mitral annular plane systolic excursion; finally, right atrial area. A total of 165 measurements (on 21 patients) were performed, 31 occurring during hypotension. The conclusions reached were during acute blood loss LA dimension changed earlier than CVP, and, in one patient, a dynamic left ventricular (LV) obstruction was observed; in 3 patients a transient LV systolic dysfunction was documented. The comparison between 39 CO paired measurements obtained by TEE and PiCCO2 revealed a statistically significant correlation (P < 0.001, r = 0.83). In this pilot study TEE successfully answered the questions raised by the anesthesiologists. Larger cohort studies are needed to address this issue.
Resumo:
BACKGROUND: Wireless capsule endoscopy has been introduced as an innovative, non-invasive diagnostic technique for evaluation of the gastrointestinal tract, reaching places where conventional endoscopy is unable to. However, the output of this technique is an 8 hours video, whose analysis by the expert physician is very time consuming. Thus, a computer assisted diagnosis tool to help the physicians to evaluate CE exams faster and more accurately is an important technical challenge and an excellent economical opportunity. METHOD: The set of features proposed in this paper to code textural information is based on statistical modeling of second order textural measures extracted from co-occurrence matrices. To cope with both joint and marginal non-Gaussianity of second order textural measures, higher order moments are used. These statistical moments are taken from the two-dimensional color-scale feature space, where two different scales are considered. Second and higher order moments of textural measures are computed from the co-occurrence matrices computed from images synthesized by the inverse wavelet transform of the wavelet transform containing only the selected scales for the three color channels. The dimensionality of the data is reduced by using Principal Component Analysis. RESULTS: The proposed textural features are then used as the input of a classifier based on artificial neural networks. Classification performances of 93.1% specificity and 93.9% sensitivity are achieved on real data. These promising results open the path towards a deeper study regarding the applicability of this algorithm in computer aided diagnosis systems to assist physicians in their clinical practice.
Resumo:
Introdução: Muitos dos instrumentos disponíveis para a avaliação do equilíbrio, risco de queda e medo de cair medem apenas actividades simples no domicílio e apresentam tendência para um “efeito de tecto” em idosos residentes na comunidade. A “Activities-specific Balance Confidence (ABC) Scale” foi concebida para avaliar o equilíbrio de forma abrangente, num conjunto de actividades de vida diária associadas a um largo espectro de dificuldade. Objectivos: Traduzir para português e adaptar culturalmente para Portugal a “Activities-specific Balance Confidence (ABS) Scale” e avaliar a sua fiabilidade. População e Métodos: Tradução e adaptação cultural do instrumento e subsequente aplicação a uma população idosa portuguesa, para determinação da sua fiabilidade inter-observador, fiabilidade intra-observador e consistência interna. Resultados: Os resultados foram muito homogéneos na grande maioria das comparações realizadas, quer intra-observador, quer inter-observador. A avaliação da consistência interna revelou valores muito elevados. Estes níveis de fiabilidade mantiveram-se mesmo removendo qualquer uma das 16 questões que compõem o questionário, mantendo-se praticamente constantes os valores registados com o questionário completo. Conclusões: A versão portuguesa da escala ABC demonstrou boa fiabilidade intra-observador, fiabilidade inter-observador e consistência interna na avaliação da auto-percepção do equilíbrio para diversas actividades de vida diária numa população idosa portuguesa. Outros trabalhos serão necessários para avaliar a utilidade desta escala na avaliação do risco de queda e do efeito de intervenções terapêuticas nesta população.
Resumo:
Surveillance registers monitor the prevalence of cerebral palsy and the severity of resulting impairments across time and place. The motor disorders of cerebral palsy can affect children’s speech production and limit their intelligibility. We describe the development of a scale to classify children’s speech performance for use in cerebral palsy surveillance registers, and its reliability across raters and across time. Speech and language therapists, other healthcare professionals and parents classified the speech of 139 children with cerebral palsy (85 boys, 54 girls; mean age 6.03 years, SD 1.09) from observation and previous knowledge of the children. Another group of health professionals rated children’s speech from information in their medical notes. With the exception of parents, raters reclassified children’s speech at least four weeks after their initial classification. Raters were asked to rate how easy the scale was to use and how well the scale described the child’s speech production using Likert scales. Inter-rater reliability was moderate to substantial (k > .58 for all comparisons). Test–retest reliability was substantial to almost perfect for all groups (k > .68). Over 74% of raters found the scale easy or very easy to use; 66% of parents and over 70% of health care professionals judged the scale to describe children’s speech well or very well. We conclude that the Viking Speech Scale is a reliable tool to describe the speech performance of children with cerebral palsy, which can be applied through direct observation of children or through case note review.
Resumo:
The anti-HIV drug abacavir is associated with idiosyncratic hypersensitivity reactions and cardiotoxicity. Although the mechanism underlying abacavir-toxicity is not fully understood, drug bioactivation to reactive metabolites may be involved. This work was aimed at identifying abacavir-protein adducts in the hemoglobin of HIV patients as biomarkers of abacavir bioactivation and protein modification. The protocol received prior approval from the Hospital Ethics Committee, patients gave their written informed consent and adherence was controlled through a questionnaire. Abacavir-derived Edman adducts with the N-terminal valine of hemoglobin were analyzed by an established liquid chromatography-electrospray ionization-tandem mass spectrometry method. Abacavir-valine adducts were detected in three out of ten patients. This work represents the first evidence of abacavir-protein adduct formation in humans. The data confirm the ability of abacavir to modify self-proteins and suggest that the molecular mechanism(s) of some abacavir-induced adverse reactions may require bioactivation.
Resumo:
BACKGROUND: The use of cardiac output monitoring may improve patient outcomes after major surgery. However, little is known about the use of this technology across nations. METHODS: This is a secondary analysis of a previously published observational study. Patients aged 16 years and over undergoing major non-cardiac surgery in a 7-day period in April 2011 were included into this analysis. The objective is to describe prevalence and type of cardiac output monitoring used in major surgery in Europe. RESULTS: Included in the analysis were 12,170 patients from the surgical services of 426 hospitals in 28 European nations. One thousand four hundred and sixteen patients (11.6 %) were exposed to cardiac output monitoring, and 2343 patients (19.3 %) received a central venous catheter. Patients with higher American Society of Anesthesiologists (ASA) scores were more frequently exposed to cardiac output monitoring (ASA I and II, 643 patients [8.6 %]; ASA III-V, 768 patients [16.2 %]; p < 0.01) and central venous catheter (ASA I and II, 874 patients [11.8 %]; ASA III-V, 1463 patients [30.9 %]; p < 0.01). In elective surgery, 990 patients (10.8 %) were exposed to cardiac output monitoring, in urgent surgery 252 patients (11.7 %) and in emergency surgery 173 patients (19.8 %). A central venous catheter was used in 1514 patients (16.6 %) undergoing elective, in 480 patients (22.2 %) undergoing urgent and in 349 patients (39.9 %) undergoing emergency surgery. Nine hundred sixty patients (7.9 %) were monitored using arterial waveform analysis, 238 patients (2.0 %) using oesophageal Doppler ultrasound, 55 patients (0.5 %) using a pulmonary artery catheter and 44 patients (2.0 %) using other technologies. Across nations, cardiac output monitoring use varied from 0.0 % (0/249 patients) to 27.5 % (19/69 patients), whilst central venous catheter use varied from 5.6 % (7/125 patients) to 43.2 % (16/37 patients). CONCLUSIONS: One in ten patients undergoing major surgery is exposed to cardiac output monitoring whilst one in five receives a central venous catheter. The use of both technologies varies widely across Europe.
Resumo:
An early and accurate recognition of success in treating obesity may increase the compliance of obese children and their families to intervention programs. This observational, prospective study aimed to evaluate the ability and the time to detect a significant reduction of adiposity estimated by body mass index (BMI), percentage of fat mass (%FM), and fat mass index (FMI) during weight management in prepubertal obese children.