8 resultados para Resynchronization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The demonstrated benefits of cardiac resynchronization therapy (CRT) in reducing mortality and hospitalizations for heart failure, improving NYHA functional class and inducing reverse remodeling have led to its increasing use in clinical practice. However, its potential contribution to complex ventricular arrhythmias is controversial.We present the case of a female patient with valvular heart failure and severe systolic dysfunction, in NYHA class III and under optimal medical therapy, without previous documented ventricular arrhythmias. After implantation of a CRT defibrillator, she suffered an arrhythmic storm with multiple episodes of monomorphic ventricular tachycardia (VT), requiring 12 shocks. Subsequently, a pattern of ventricular bigeminy was observed, as well as reproducible VT runs induced by biventricular pacing. Since no other vein of the coronary sinus system was accessible, it was decided to implant an epicardial lead to stimulate the left ventricle, positioned in the left ventricular mid-lateral wall. No arrhythmias were detected in the following six months. This case highlights the possible proarrhythmic effect of biventricular pacing with a left ventricular lead positioned in the coronary sinus venous system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Left ventricular reverse remodeling (LVRR), defined as reduction of end-diastolic and end-systolic dimensions and improvement of ejection fraction, is associated with the prognostic implications of cardiac resynchronization therapy (CRT). The time course of LVRR remains poorly characterized. Nevertheless, it has been suggested that it occurs ≤6 months after CRT. OBJECTIVE: To characterize the long-term echocardiographic and clinical evolution of patients with LVRR occurring >6 months after CRT and to identify predictors of a delayed LVRR response. METHODS: A total of 127 consecutive patients after successful CRT implantation were divided into three groups according to LVRR response: Group A, 19 patients (15%) with LVRR after >6 months (late LVRR); Group B, 58 patients (46%) with LVRR before 6 months (early LVRR); and Group C, 50 patients (39%) without LVRR during follow-up (no LVRR). RESULTS: The late LVRR group was older, more often had ischemic etiology and fewer patients were in NYHA class ≤II. Overall, group A presented LVRR between group B and C. This was also the case with the percentage of clinical response (68.4% vs. 94.8% vs. 38.3%, respectively, p<0.001), and hospital readmissions due to decompensated heart failure (31.6% vs. 12.1% vs. 57.1%, respectively, p<0.001). Ischemic etiology (OR 0.044; p=0.013) and NYHA functional class

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: The significant risk of sudden arrhythmic death in patients with congestive heart failure and electromechanical ventricular dyssynchrony has led to increased use of combined cardiac resynchronization therapy defibrillator (CRT-D) devices. OBJECTIVES: To evaluate the echocardiographic variables in patients undergoing CRT-D that predict the occurrence of appropriate therapies (AT) for ventricular tachyarrhythmia. METHODS: We analyzed 38 consecutive patients (mean age 60 +/- 12 years, 63% male) with echocardiographic evaluation before and 6 months after CRT-D implantation. Patients with AT were identified in a mean follow-up of 471 +/- 323 days. A standard echocardiographic study was performed including tissue Doppler imaging (TDI). Responders were defined as patients with improvement in NYHA class of < or = 1 in the first six months, and reverse remodeling as a decrease in left ventricular end-systolic volume of < or = 15% and/or an increase in left ventricular ejection fraction of > 25%. RESULTS: The responder rate was 74%, and the reverse remodeling rate was 55%. AT occurred in 21% of patients, who presented with greater left ventricular end-diastolic internal diameter (LVEDD) before implantation (86 +/- 8 vs. 76 +/- 11 mm, p = 0.03) and at 6 months (81 +/- 8 vs. 72 +/- 14 mm, p = 0.08), and increased left ventricular end-systolic internal diameter (66 +/- 14 vs. 56 +/- 14 mm, p = 0.03) and lower ejection fraction (24 +/- 6 vs. 34 +/- 14%, p = 0.08) at 6 months. In the group with AT, the responder rate was lower (38 vs. 83%, p = 0.03), without significant differences in reverse remodeling (38% for the AT group vs. 60%, p = 0.426) or in the other variables. By univariate analysis, predictors of AT were LVEDD before implantation and E' after implantation. Age, gender, ischemic etiology, use of antiarrhythmic drugs, reverse remodeling and the other echocardiographic parameters did not predict AT. In multivariate logistic regression analysis, both LVEDD before implantation (OR 1.24, 95% CI 1.04-1.48, p = 0.019) and postimplantation E' (OR 0.27, 95% CI 0.09-0.76, p = 0.014) remained as independent predictors of AT. CONCLUSIONS: In patients undergoing CRT-D, episodes of ventricular tachyarrhythmia occur with high incidence, independently of echocardiographic response, with LVEDD before implantation and E' after implantation as the only independent predictors of AT in the medium-term. These results highlight the importance of combined devices with defibrillation capability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Recent clinical trials have studied parameters that could predict response to cardiac resynchronization therapy (CRT) in patients with advanced heart failure. Left ventricular end-diastolic dimension (LVEDD) is regarded as a possible predictor of response to CRT. OBJECTIVE: To study the response to CRT in patients with very dilated cardiomyopathy, i.e. those at a more advanced stage of the pathology, analyzing both the responder rate and reverse remodeling in two groups of patients classified according to LVEDD. METHODS: We performed a retrospective analysis of 71 patients who underwent CRT (aged 62 +/- 11 years; 65% male; 93% in NYHA functional class > or = III; 31% with ischemic cardiomyopathy; left ventricular ejection fraction [LVEF] 25.6 +/- 6.8%; 32% in atrial fibrillation; QRS 176 +/- 31 ms). Twenty-two (31%) patients with LVEDD > or = 45 mm/m2 (49.2 +/- 3.5 mm/m2) were considered to have very dilated cardiomyopathy (Group A) and 49 patients had LVEDD > 37 mm/m2 and < 45 mm/m2 (39.4 +/- 3.8 mm/m2) (Group B). All patients were assessed by two-dimensional echocardiography at baseline and six months after CRT. The following parameters were analyzed: NYHA functional class, LVEF and LVEDD. Responders were defined clinically (improvement of > or = 1 NYHA class) and by echocardiography, with a minimum 15% increase over baseline LVEF combined with a reduction in LVEDD (reverse remodeling). RESULTS: There were no significant differences in baseline demographic characteristics between the two groups. At six-month followup, we observed an improvement in LVEF (delta 8.5 +/- 11.8%) and a reduction in LVEDD (delta 3.7 +/- 6.8 mm/m2), with fifty-seven (79%) patients being classified as clinical responders. The percentage of patients with reverse remodeling was similar in both groups (64% vs. 73%, p = NS), as were percentages of improved LVEF (delta 6.3 +/- 11% vs. delta 9.6 +/- 12%; p = NS) and decreased LVEDD (delta 3.7 +/- 5.5 mm/m2 vs. delta 3.7 +/- 7.4 mm/m2; p = NS). We found a higher percentage of clinical responders in patients with very dilated cardiomyopathy (96% vs. 72%, p < 0.05). CONCLUSION: In this study, a significant number of responders showed reverse remodeling after CRT. Although a higher percentage of patients with very dilated cardiomyopathy showed improvement in functional class, the extent of reverse remodeling was similar in both groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: A growing body of evidence shows the prognostic value of oxygen uptake efficiency slope (OUES), a cardiopulmonary exercise test (CPET) parameter derived from the logarithmic relationship between O(2) consumption (VO(2)) and minute ventilation (VE) in patients with chronic heart failure (CHF). OBJECTIVE: To evaluate the prognostic value of a new CPET parameter - peak oxygen uptake efficiency (POUE) - and to compare it with OUES in patients with CHF. METHODS: We prospectively studied 206 consecutive patients with stable CHF due to dilated cardiomyopathy - 153 male, aged 53.3±13.0 years, 35.4% of ischemic etiology, left ventricular ejection fraction 27.7±8.0%, 81.1% in sinus rhythm, 97.1% receiving ACE-Is or ARBs, 78.2% beta-blockers and 60.2% spironolactone - who performed a first maximal symptom-limited treadmill CPET, using the modified Bruce protocol. In 33% of patients an cardioverter-defibrillator (ICD) or cardiac resynchronization therapy device (CRT-D) was implanted during follow-up. Peak VO(2), percentage of predicted peak VO(2), VE/VCO(2) slope, OUES and POUE were analyzed. OUES was calculated using the formula VO(2) (l/min) = OUES (log(10)VE) + b. POUE was calculated as pVO(2) (l/min) / log(10)peakVE (l/min). Correlation coefficients between the studied parameters were obtained. The prognosis of each variable adjusted for age was evaluated through Cox proportional hazard models and R2 percent (R2%) and V index (V6) were used as measures of the predictive accuracy of events of each of these variables. Receiver operating characteristic (ROC) curves from logistic regression models were used to determine the cut-offs for OUES and POUE. RESULTS: pVO(2): 20.5±5.9; percentage of predicted peak VO(2): 68.6±18.2; VE/VCO(2) slope: 30.6±8.3; OUES: 1.85±0.61; POUE: 0.88±0.27. During a mean follow-up of 33.1±14.8 months, 45 (21.8%) patients died, 10 (4.9%) underwent urgent heart transplantation and in three patients (1.5%) a left ventricular assist device was implanted. All variables proved to be independent predictors of this combined event; however, VE/VCO2 slope was most strongly associated with events (HR 11.14). In this population, POUE was associated with a higher risk of events than OUES (HR 9.61 vs. 7.01), and was also a better predictor of events (R2: 28.91 vs. 22.37). CONCLUSION: POUE was more strongly associated with death, urgent heart transplantation and implantation of a left ventricular assist device and proved to be a better predictor of events than OUES. These results suggest that this new parameter can increase the prognostic value of CPET in patients with CHF.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: A terapêutica de ressincronização cardíaca (TRC) tem benefícios significativos em doentes seleccionados. O impacto desta modalidade na incidência de taquidisritmias ventriculares permanece controverso. Analisámos a ocorrência de terapêuticas apropriadas em doentes submetidos a TRC combinada com cardioversor-desfibrilhador (CDI). Métodos: Estudo de 123 doentes com fracção de ejecção ventricular esquerda (FEVE) < 35%, submetidos a implantação com sucesso de TRC-CDI ou CDI isoladamente (prevenção primária). Resultados: Idade média foi 63±12 anos, FEVE de 25±6%, seguimento mediano de 372 dias. Implantou-se TRC-CDI em 63 doentes (grupo A) e CDI isoladamente em 60 doentes (grupo B). No grupo A tivemos 86% de respondedores clínicos, menor prevalência de miocardiopatia isquémica(30% versus 72%), e mais doentes em classe III da NYHA antes da implantação do dispositivo(90% versus 7%) comparativamente com o grupo com CDI isoladamente. Não se identificaram diferenças relativamente à incidência de terapêuticas apropriadas (19% versus 12%) ou no tempo para a primeira terapêutica (305 dias versus 293 dias). A mortalidade total foi de 11% no grupo A e de 12% no grupo B. As curvas de Kaplan-Meier para eventos arrítmicos em doentes com TRC, não mostraram diferenças significativas (HR 3,02, IC 95% 0,82-11,09, p = NS) comparativamente com doentes sem TRC. Conclusões: Em doentes submetidos a TRC-CDI por prevenção primária, apesar da elevada taxa de respondedores, a incidência de terapêuticas apropriadas não foi diferente do obtido em doentes com CDI isoladamente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Based on a survey sent to Portuguese centers that perform diagnostic and interventional electrophysiology and/or implantable cardioverter-defibrillator (ICD) implantations, the authors analyze the number and type of procedures performed during 2012 and compare these data with previous years. In 2012, a total of 2561 diagnostic electrophysiologic studies were performed, which were followed by ablation in 2017 cases, representing a steady situation compared with the previous year. There was a 12% increase in the number of ablation procedures for atrial fibrillation, making it for the first time the most frequent indication for ablation, overtaking atrioventricular nodal reentrant tachycardia. The total number of first ICD implantations was 1048 (around 100 per million population), of which 375 were cardiac resynchronization devices (BiV ICDs). This represents a slight decrease (3.3%) in the total number of new implants, with an increase of 10% in the number of BiV ICDs compared to the previous year. However, there was a considerable increase in the number of ICD generator replacements, resulting in an overall increase of 3.5% in implantations performed in 2012. Some comments are made regarding developments in this activity and its current status, and on some factors that may influence the dynamics of this area of interventional cardiology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: Device-based remote monitoring (RM) has been linked to improved clinical outcomes at short to medium-term follow-up. Whether this benefit extends to long-term follow-up is unknown. We sought to assess the effect of device-based RM on long-term clinical outcomes in recipients of implantable cardioverter-defibrillators (ICD). METHODS: We performed a retrospective cohort study of consecutive patients who underwent ICD implantation for primary prevention. RM was initiated with patient consent according to availability of RM hardware at implantation. Patients with concomitant cardiac resynchronization therapy were excluded. Data on hospitalizations, mortality and cause of death were systematically assessed using a nationwide healthcare platform. A Cox proportional hazards model was employed to estimate the effect of RM on mortality and a composite endpoint of cardiovascular mortality and hospital admission due to heart failure (HF). RESULTS: 312 patients were included with a median follow-up of 37.7months (range 1 to 146). 121 patients (38.2%) were under RM since the first outpatient visit post-ICD and 191 were in conventional follow-up. No differences were found regarding age, left ventricular ejection fraction, heart failure etiology or NYHA class at implantation. Patients under RM had higher long-term survival (hazard ratio [HR] 0.50, CI 0.27-0.93, p=0.029) and lower incidence of the composite outcome (HR 0.47, CI 0.27-0.82, p=0.008). After multivariate survival analysis, overall survival was independently associated with younger age, higher LVEF, NYHA class lower than 3 and RM. CONCLUSION: RM was independently associated with increased long-term survival and a lower incidence of a composite endpoint of hospitalization for HF or cardiovascular mortality.