3 resultados para Radial and linear endobronchial ultrasound


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Anatomical variations of the extensor tendons to the fingers are of great clinical interest, due to the relatively high frequency of tendon injury in clinical practice. Material and methods: During routine dissection of the right upper limb of a 67-year-old female preserved corpse, the extensor indicis proprius (EIP) muscle belly originated 3 independent tendons, each with a separate fascial sheath, forming a triple EIP tendon. There was a larger tendon, which occupied a central position, that represented the usual single EIP tendon. In addition, there were two thinner radial and ulnar accessory EIP tendons. The radial-EIP tendon crossed deep to the extensor digitorum communis (EDC) tendon to the index finger in the distal half of the dorsum of the hand to reach the radial side of the extensor expansion hood of the index finger. Discussion: According to the literature, the frequency of a triple EIP tendon ranges from 0%, to as high as 7%, although most authors do not acknowledge the presence of this variant in their series. This variant of the EIP tendon, in which the radial-EIP terminated laterally to the termination of the tendon of the EDC to the index finger, may be a source of confusion intraoperatively, as the EIP tendon has traditionally been identified on the basis of its ulnar location with respect to the EDC tendon. Conclusion: The possibility of a triple EIP tendon should certainly be born in mind by all surgeons when performing tendon repairs, tenoplasties or tendon transfers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Overview and Aims: The contraceptive implant is frequently used to provide contraceptive protection over three years. The implant is inserted into the subcutaneous tissue of the upper arm, and should be palpable and easily removed. We evaluated the best imaging strategy for non-palpable implant (Implanon®) localization and removal. Study Design: Retrospective study. Population: A total of 11 women referred to a tertiary care hospital, between October 2009 and January 2012, for localization and removal of their non-palpable implants. Methods: Different localization methods (ultrasound and magnetic resonance imaging) were evaluated for non-palpable rod. Results: Seven of the nonpalpable implants were inserted in a health care center, three in a district hospital and one in a private clinic. In three women, the reasons for requesting removal were the end of the implant validity, two wanted to become pregnant, two had weight gain, one had weight loss, one referred irregular bleeding, one had two implants and one did a hysterectomy. In 81.8% (9) of the women, the implants were identified and localized by ultrasound, and successfully removed. In two patients the implant was not found and therefore not removed. Conclusions: In our study, high resolution ultrasound proved to be a sensitive method in implants localization, being the primary choice for determining the location of nonpalpable implants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Adnexal torsion is a rare event whose diagnosis requires a high degree of suspicion since its presentation is clinical and laboratory nonspecific. Ultrasound constitute the first-line exam in the imaging evaluation and timely surgical treatment, with detorsion, is mandatory to allow the preservation of the structures involved. The effectiveness of preventive measures of recurrence is yet to be determined. In this paper, in addition to a literature review, the authors present a new imaging finding and propose a flowchart for therapeutic decision.