6 resultados para Optic testing
Resumo:
AIMS: Protocols using sublingual nitrates have been increasingly used to improve diagnostic accuracy of head-up tilt testing (HUT). Nevertheless, exaggerated responses to nitrates have been frequently described, particularly in elderly patients. The aim of this article is to evaluate, in an elderly population with unexplained syncope, whether the impact of sublingual nitroglycerin (NTG) used as a provocative agent is dose-dependent. METHODS AND RESULTS: One hundred and twenty consecutive elderly patients submitted to HUT using NTG after an asymptomatic drug-free phase were studied. Patients were divided into three groups according to the NTG dosage: 500, 375 and 250 microg. The test was considered positive when there was reproduction of symptoms with bradycardia and/or arterial hypotension. A gradual decrease in the blood pressure after NTG was considered an exaggerated response to nitrates. There were no differences in the clinical characteristics of the different subgroups. A positive test was obtained in 50% of the patients in each group. The rate of exaggerated responses was identical in all groups and ranged between 15 and 17%. CONCLUSION: In an elderly population with syncope of unknown origin submitted to HUT, the response to NTG is not dose-dependent, and no difference was found in the rate of exaggerated responses to nitrates with different NTG dosages.
Resumo:
INTRODUCTION: A growing body of evidence shows the prognostic value of oxygen uptake efficiency slope (OUES), a cardiopulmonary exercise test (CPET) parameter derived from the logarithmic relationship between O(2) consumption (VO(2)) and minute ventilation (VE) in patients with chronic heart failure (CHF). OBJECTIVE: To evaluate the prognostic value of a new CPET parameter - peak oxygen uptake efficiency (POUE) - and to compare it with OUES in patients with CHF. METHODS: We prospectively studied 206 consecutive patients with stable CHF due to dilated cardiomyopathy - 153 male, aged 53.3±13.0 years, 35.4% of ischemic etiology, left ventricular ejection fraction 27.7±8.0%, 81.1% in sinus rhythm, 97.1% receiving ACE-Is or ARBs, 78.2% beta-blockers and 60.2% spironolactone - who performed a first maximal symptom-limited treadmill CPET, using the modified Bruce protocol. In 33% of patients an cardioverter-defibrillator (ICD) or cardiac resynchronization therapy device (CRT-D) was implanted during follow-up. Peak VO(2), percentage of predicted peak VO(2), VE/VCO(2) slope, OUES and POUE were analyzed. OUES was calculated using the formula VO(2) (l/min) = OUES (log(10)VE) + b. POUE was calculated as pVO(2) (l/min) / log(10)peakVE (l/min). Correlation coefficients between the studied parameters were obtained. The prognosis of each variable adjusted for age was evaluated through Cox proportional hazard models and R2 percent (R2%) and V index (V6) were used as measures of the predictive accuracy of events of each of these variables. Receiver operating characteristic (ROC) curves from logistic regression models were used to determine the cut-offs for OUES and POUE. RESULTS: pVO(2): 20.5±5.9; percentage of predicted peak VO(2): 68.6±18.2; VE/VCO(2) slope: 30.6±8.3; OUES: 1.85±0.61; POUE: 0.88±0.27. During a mean follow-up of 33.1±14.8 months, 45 (21.8%) patients died, 10 (4.9%) underwent urgent heart transplantation and in three patients (1.5%) a left ventricular assist device was implanted. All variables proved to be independent predictors of this combined event; however, VE/VCO2 slope was most strongly associated with events (HR 11.14). In this population, POUE was associated with a higher risk of events than OUES (HR 9.61 vs. 7.01), and was also a better predictor of events (R2: 28.91 vs. 22.37). CONCLUSION: POUE was more strongly associated with death, urgent heart transplantation and implantation of a left ventricular assist device and proved to be a better predictor of events than OUES. These results suggest that this new parameter can increase the prognostic value of CPET in patients with CHF.
Resumo:
PURPOSE: 1. Identify differences in optic nerve sheath diameter (ONSD) as an indirect measure of intracranial pressure (ICP) in glaucoma patients and a healthy population. 2. Identify variables that may correlate with ONSD in primary open-angle glaucoma (POAG) and normal tension glaucoma (NTG) patients. METHODS: Patients with NTG (n = 46) and POAG (n = 61), and healthy controls (n = 42) underwent B-scan ultrasound measurement of ONSD by an observer masked to the patient diagnosis. Intraocular pressure (IOP) was measured in all groups, with additional central corneal thickness (CCT) and visual field defect measurements in glaucomatous patients. Only one eye per patient was selected. Kruskal-Wallis or Mann-Whitney were used to compare the different variables between the diagnostic groups. Spearman correlations were used to explore relationships among these variables. RESULTS: ONSD was not significantly different between healthy, NTG and POAG patients (6.09 ± 0.78, 6.03 ± 0.69, and 5.71 ± 0.83 respectively; p = 0.08). Visual field damage and CCT were not correlated with ONSD in either of the glaucoma groups (POAG, p = 0.31 and 0.44; NTG, p = 0.48 and 0.90 respectively). However, ONSD did correlate with IOP in NTG patients (r = 0.53, p < 0.001), while it did not in POAG patients and healthy controls (p = 0.86, p = 0.46 respectively). Patient's age did not relate to ONSD in any of the groups (p > 0.25 in all groups). CONCLUSIONS: Indirect measurements of ICP by ultrasound assessment of the ONSD may provide further insights into the retrolaminar pressure component in glaucoma. The correlation of ONSD with IOP solely in NTG patients suggests that the translaminar pressure gradient may be of particular importance in this type of glaucoma.
Resumo:
Background: Allergic rhinitis and asthma (ARA) are chronic inflammatory diseases of the airways that often coexist in children. The only tool to assess the ARA control, the Control of Allergic Rhinitis and Asthma Test (CARAT) is to be used by adults. We aimed to develop the Pediatric version of Control of Allergic Rhinitis and Asthma Test (CARATkids) and to test its comprehensibility in children with 4 to 12 years of age. Methods: The questionnaire development included a literature review of pediatric questionnaires on asthma and/or rhinitis control and two consensus meetings of a multidisciplinary group. Cognitive testing was carried out in a cross-sectional qualitative study using cognitive interviews. Results: Four questionnaires to assess asthma and none to assess rhinitis control in children were identified. The multidisciplinary group produced a questionnaire version for children with 17 questions with illustrations and dichotomous (yes/no) response format. The version for caregivers had 4-points and dichotomous scales. Twenty-nine children, 4 to 12 years old, and their caregivers were interviewed. Only children over 6 years old could adequately answer the questionnaire. A few words/expressions were not fully understood by children of 6 to 8 years old. The drawings illustrating the questions were considered helpful by children and caregivers. Caregivers considered the questionnaire complete and clear and preferred dichotomous over the 4-points scales. The proportion of agreement between children and their caregivers was 61%. The words/expressions that were difficult to understand were amended. Conclusion: CARATkids, the first questionnaire to assess a child’s asthma and rhinitis control was developed and its content validity was assured. Cognitive testing showed that CARATKids is well-understood by children 6 to 12 years old. The questionnaire’s measurement properties can now be assessed in a validation study.
Resumo:
INTRODUCTION AND OBJECTIVES: Recurrent syncope has a significant impact on quality of life. The development of measurement scales to assess this impact that are easy to use in clinical settings is crucial. The objective of the present study is a preliminary validation of the Impact of Syncope on Quality of Life questionnaire for the Portuguese population. METHODS: The instrument underwent a process of translation, validation, analysis of cultural appropriateness and cognitive debriefing. A population of 39 patients with a history of recurrent syncope (>1 year) who underwent tilt testing, aged 52.1 ± 16.4 years (21-83), 43.5% male, most in active employment (n=18) or retired (n=13), constituted a convenience sample. The resulting Portuguese version is similar to the original, with 12 items in a single aggregate score, and underwent statistical validation, with assessment of reliability, validity and stability over time. RESULTS: With regard to reliability, the internal consistency of the scale is 0.9. Assessment of convergent and discriminant validity showed statistically significant results (p<0.01). Regarding stability over time, a test-retest of this instrument at six months after tilt testing with 22 patients of the sample who had not undergone any clinical intervention found no statistically significant changes in quality of life. CONCLUSIONS: The results indicate that this instrument is of value for assessing quality of life in patients with recurrent syncope in Portugal.
Resumo:
Introdução: Os drusens do disco ótico são anomalias congénitas do desenvolvimento da cabeça do nervo ótico, correspondendo a depósitos hialinos calcificados, localizados anteriormente à lâmina crivosa. O seu diagnóstico é maioritariamente acidental, em doentes normalmente assintomáticos. Material e Métodos: Os autores apresentam 5 casos clínicos de doentes com idades de apresentação compreendidas entre 6 e 12 anos, observados na Consulta de Oftalmologia Pediátrica e Estrabismo, à qual foram referenciados por diferentes motivos. Resultados: Nos casos clínicos apresentados os motivos de consulta foram diminuição da acuidade visual, estrabismo divergente, cefaleias com suspeita de papiledema e rotina. O exame oftalmológico e os meios complementares de diagnóstico realizados, nomeadamente retinografia, ecografia ocular, tomografia de coerência ótica e campos visuais, contribuíram para o diagnóstico de drusens do nervo ótico. Foram ainda encontrados erros refractivos em 4 dos casos descritos. Conclusão: Salienta-se a importância de uma história clínica e observação detalhadas para o diagnóstico diferencial e despiste de patologias oftalmológicas concomitantes, em doentes com drusens do disco ótico e seus familiares.