5 resultados para Normalization Methods


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: A new method for determining serum specific IgE (IMMULITE“ 2000 3gAllergy) has recently become available. Objective: To evaluate the clinical performance of IMMULITE 2000 in the diagnosis of cow’s milk allergy compared with that of UniCAP“. Additionally, we verified the behavior of both methods at two diagnostic decision points proposed by other authors. Methods: The study population consisted of 31 children with cow’s milk allergy (group A) and a control group of 19 atopic children without food allergy(group B). A blood sample from each child was tested using both methods and the results were compared. Results: In group A, the values for cow’s milk IgE ranged from 0.35 kU/L (the lowest common detection limit) to above 100 kU/L. In group B, the values were less than 1.1 kU/L for IMMULITE 2000 and less than 1.6 kU/L for UniCAP. An agreement of 90 % in IgE classes was obtained. Both methods demonstrated exactly the same diagnostic performance(sensitivity: 100 %; specificity: 78.9 %; negative predictive value: 100%; positive predictive value: 84.6%;efficiency: 90.2 %). The evaluation of the two methods at the two different decision points proposed in the literature showed a better positive predictive value with UniCAP, but we obtained equivalent performance with IMMULITE 2000 by choosing higher cutoff values. Conclusions: We conclude that IMMULITE 2000 is as effective as UniCAP in the diagnosis of cow’s milk allergy. Both methods can be used to obtain site-specific decision points that are population, age and disease dependent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare measurements of the upper arm cross-sectional areas (total arm area,arm muscle area, and arm fat area of healthy neonates) as calculated using anthropometry with the values obtained by ultrasonography. Materials and methods: This study was performed on 60 consecutively born healthy neonates: gestational age (mean6SD) 39.661.2 weeks, birth weight 3287.16307.7 g, 27 males (45%) and 33 females (55%). Mid-arm circumference and tricipital skinfold thickness measurements were taken on the left upper mid-arm according to the conventional anthropometric method to calculate total arm area, arm muscle area and arm fat area. The ultrasound evaluation was performed at the same arm location using a Toshiba sonolayer SSA-250AÒ, which allows the calculation of the total arm area, arm muscle area and arm fat area by the number of pixels enclosed in the plotted areas. Statistical analysis: whenever appropriate, parametric and non-parametric tests were used in order to compare measurements of paired samples and of groups of samples. Results: No significant differences between males and females were found in any evaluated measurements, estimated either by anthropometry or by ultrasound. Also the median of total arm area did not differ significantly with either method (P50.337). Although there is evidence of concordance of the total arm area measurements (r50.68, 95% CI: 0.55–0.77) the two methods of measurement differed for arm muscle area and arm fat area. The estimated median of measurements by ultrasound for arm muscle area were significantly lower than those estimated by the anthropometric method, which differed by as much as 111% (P,0.001). The estimated median ultrasound measurement of the arm fat was higher than the anthropometric arm fat area by as much as 31% (P,0.001). Conclusion: Compared with ultrasound measurements using skinfold measurements and mid-arm circumference without further correction may lead to overestimation of the cross-sectional area of muscle and underestimation of the cross-sectional fat area. The correlation between the two methods could be interpreted as an indication for further search of correction factors in the equations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiopulmonary exercise testing (CPET) is an objective method for assessment of functional capacity and for prognostic stratification of patients with chronic heart failure (CHF). In this study, we analyzed the prognostic value of a recently described CPET-derived parameter, the minute ventilation to carbon dioxide production slope normalized for peak oxygen consumption (VE/VCO2 slope/pVO2). METHODS: We prospectively studied 157 patients with stable CHF and dilated cardiomyopathy who performed maximal CPET using the modified Bruce protocol. The prognostic value of VE/VCO2 slope/pVO2 was determined and compared with traditional CPET parameters. RESULTS: During follow-up 37 patients died and 12 were transplanted. Mean follow-up in surviving patients was 29.7 months (12-36). Cox multivariate analysis revealed that VE/VCO2 slope/pVO2 had the greatest prognostic power of all the parameters studied. A VE/VCO2 slope/pVO2 of > or = 2.2 signaled cases at higher risk. CONCLUSION: Normalization of the ventilatory response to exercise for peak oxygen consumption appears to increase the prognostic value of CPET in patients with CHF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Children with Gaucher disease type I (GD1) are usually treated with enzyme replacement therapy (ERT) at a dose of 30-60U/Kg/2W. Recently, due to an acute shortage supply of imiglucerase, a reduced dose or a reduced infusion frequency was recommended. Objective: To evaluate the effects of a reduced infusion frequency of imiglucerase over 15 months of follow-up. Patients and Methods: Three patients (1M:2F) were treated with ERT since a median age of 7 years (range 5-12). Only one had bone crisis and Erlenmeyer deformations. Median duration of treatment before dose reduction was 3 years (range 1-8). ERT resulted in total regression of symptoms, normalization of hematological parameters and progressive improvement of chitotriosidase in all patients. In August 2009 infusion schedule was changed from a media 45U/Kg every two weeks to every four weeks. Results: All patients remained asymptomatic and with no major change on hematological parameters except for the patient with bone crisis who presented subnormal platelet count. All patients showed an upward trend in chitotriosidase values. Comments: Although a longer follow-up is needed, is probable that even children completely stabilized can probably not be kept on lower doses even though the reduction of frequency of the infusions represent a lower social burden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinically childhood occipital lobe epilepsy (OLE) manifests itself with distinct syndromes. The traditional EEG recordings have not been able to overcome the difficulty in correlating the ictal clinical symptoms to the onset in particular areas of the occipital lobes. To understand these syndromes it is important to map with more precision the epileptogenic cortical regions in OLE. Experimentally, we studied three idiopathic childhood OLE patients with EEG source analysis and with the simultaneous acquisition of EEG and fMRI, to map the BOLD effect associated with EEG spikes. The spatial overlap between the EEG and BOLD results was not very good, but the fMRI suggested localizations more consistent with the ictal clinical manifestations of each type of epileptic syndrome. Since our first results show that by associating the BOLD effect with interictal spikes the epileptogenic areas are mapped to localizations different from those calculated from EEG sources and that by using different EEG/fMRI processing methods our results differ to some extent, it is very important to compare the different methods of processing the localization of activation and develop a good methodology for obtaining co-registration maps of high resolution EEG with BOLD localizations.