3 resultados para Natural ventilation
Resumo:
Modelling of ventilation is strongly dependent on the physical characteristics of the building of which precise evaluation is a complex and time consuming task. In the frame of a research project, two children day care centres (CDCC) have been selected in order to measure the envelope air permeability, the flow rate of mechanical ventilation systems and indoor and outdoor temperature. The data obtained was used as input to the computer code CONTAM for ventilation simulations. The results obtained were compared with direct measurements of ventilation flow from short term measurements with CO2 tracer gas and medium term measurements with perfluorocarbon tracer (PFT) gas decay method. After validation, in order to analyse the main parameters that affect ventilation, the model was used to predict the ventilation rates for a wide range of conditions. The purpose of this assessment was to find the best practices to improve natural ventilation. A simple analytical method to predict the ventilation flow rate of rooms is also presented. The method is based on the estimation of wind effect on the room through the evaluation of an average factor and on the assessment of relevant cross section of gaps and openings combined in series or in parallel. It is shown that it may be applied with acceptable accuracy for this type of buildings when ventilation is due essentially to wind action.
Resumo:
A autora aborda o historial, génese e objectivos da Classificação Internacional de Funcionalidade para crianças e jovens, implementada pela Organização Mundial de Saúdeem 2007. Sublinha o papel de complementaridadade da CIF relativamente a outras classificações como a Classificação Internacional de Doenças (CID), em que a primeira visa caracterizar as capacidades e dificuldades de crianças e jovens com deficiência, ou seja, caracterizar do ponto de vista funcional cada criança e jovem, independentemente do diagnóstico etiológico médico. Trata-se da mudança de paradigma bio-médico para a do indivíduo que apresenta determinadas competências e dificuldades, em que estas últimas são definidas em função do ambiente – facilitador ou actuando como barreira. Assim, é dado enfoque ao ambiente para que este seja modificado transformando os factores que actuam como barreira em facilitadores, que anulem ou atenuem as dificuldades. Sendo a deficiência e ou doença uma experiência universal, a CIF vem colmatar uma importante lacuna na dificuldade de comunicação e articulação entre os diversos actores intervenientes no apoio socio educativo e médico destas crianças,criando uma linguagem acessível aos técnicos envolvidos – educadores, terapeutas e outros profissionais ligados à infância, por força envolvidos, dando uma maior ênfase à interacção criança/meio numa perspectiva holística de bem estar bio-psico-social.
Resumo:
Characterized native and recombinant Hevea brasiliensis (rHev b) natural rubber latex (NRL) allergens are available to assess patient allergen sensitization profiles. OBJECTIVE: Quantification of individual IgE responses to the spectrum of documented NRL allergens and evaluation of cross-reactive carbohydrate determinants (CCDs) for more definitive diagnosis. METHODS: Sera of 104 healthcare workers (HCW; 51 German, 21 Portuguese, 32 American), 31 spina bifida patients (SB; 11 German, 20 Portuguese) and 10 Portuguese with multiple surgeries (MS) were analysed for allergen-specific IgE antibody (sIgE) to NRL, single Hev b allergens and CCDs with ImmunoCAP technology. RESULTS: In all patient groups rHev b 5-sIgE concentrations were the most pronounced. Hev b 2, 5, 6.01 and 13 were identified as the major allergens in HCW and combined with Hev b 1 and Hev b 3 in SB. In MS Hev b 1 displayed an intermediate relevance. Different sIgE antibody levels to native Hevea brasiliensis (nHev b) 2 and rHev b 6.01 allowed discrimination of SB with clinical relevant latex allergy vs. those with latex sensitization. Sensitization profiles of German, Portuguese and American patients were equivalent. rHev b 5, 6.01 and nHev b 13 combined detected 100% of the latex-allergic HCW and 80.1% of the SB. Only 8.3% of the sera showed sIgE response to CCDs. CONCLUSIONS: Hev b 1, 2, 5, 6.01 and 13 were identified as the major Hev b allergens and they should be present in standardized latex extracts and in vitro allergosorbents. CCDs are only of minor relevance in patients with clinical relevant latex allergy. Component-resolved diagnostic analyses for latex allergy set the stage for an allergen-directed immunotherapy strategy