7 resultados para Methods time measurement


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: To compare measurements of the upper arm cross-sectional areas (total arm area,arm muscle area, and arm fat area of healthy neonates) as calculated using anthropometry with the values obtained by ultrasonography. Materials and methods: This study was performed on 60 consecutively born healthy neonates: gestational age (mean6SD) 39.661.2 weeks, birth weight 3287.16307.7 g, 27 males (45%) and 33 females (55%). Mid-arm circumference and tricipital skinfold thickness measurements were taken on the left upper mid-arm according to the conventional anthropometric method to calculate total arm area, arm muscle area and arm fat area. The ultrasound evaluation was performed at the same arm location using a Toshiba sonolayer SSA-250AÒ, which allows the calculation of the total arm area, arm muscle area and arm fat area by the number of pixels enclosed in the plotted areas. Statistical analysis: whenever appropriate, parametric and non-parametric tests were used in order to compare measurements of paired samples and of groups of samples. Results: No significant differences between males and females were found in any evaluated measurements, estimated either by anthropometry or by ultrasound. Also the median of total arm area did not differ significantly with either method (P50.337). Although there is evidence of concordance of the total arm area measurements (r50.68, 95% CI: 0.55–0.77) the two methods of measurement differed for arm muscle area and arm fat area. The estimated median of measurements by ultrasound for arm muscle area were significantly lower than those estimated by the anthropometric method, which differed by as much as 111% (P,0.001). The estimated median ultrasound measurement of the arm fat was higher than the anthropometric arm fat area by as much as 31% (P,0.001). Conclusion: Compared with ultrasound measurements using skinfold measurements and mid-arm circumference without further correction may lead to overestimation of the cross-sectional area of muscle and underestimation of the cross-sectional fat area. The correlation between the two methods could be interpreted as an indication for further search of correction factors in the equations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Low-dose dobutamine stress echocardiography is a common and useful technique to assess myocardial viability in patients with ischemic cardiomyopathy. OBJECTIVE: To evaluate the use of low-dose dobutamine stress echocardiography in determining the functional status of patients with idiopathic dilated cardiomyopathy (IDCM). METHODS: Prospective study of 28 patients with IDCM by transthoracic echocardiography (2D), low-dose dobutamine stress echocardiography, cardiopulmonary exercise testing (CPET) and measurement of pro-BNP. RESULTS: The mean age of the population was 50.3 +/- 11.5 years, 9 female and 19 male. Mean ejection fraction was 32.1 +/- 9.8%. All were in sinus rhythm. The following parameters were analyzed in 2D echocardiography and after dobutamine: dimensions of left atrium (LA) and of left ventricle in diastole and systole, shortening fraction (%), left ventricular end-diastolic (EDV) and end-systolic volumes (ESV), ejection fraction (EF), and mitral inflow (E, A, E/A ratio and deceleration time). In CPET, we considered the following parameters: peak VO2 and % maximal peak VO2 attained. We compared echo results with CPET. There was a correlation between age and peak VO2 (r = -0.38 with p = 0.049). In 2D echo, there was a correlation between baseline EF and LA dimensions and peak VO2 (r = 0.45 / p = 0.004 and r = -0.49 / p = 0.014, respectively). After dobutamine echo, there was a correlation between some echo parameters and peak VO2: EF - r = 0.59 / p = 0.001, LA dimensions - r = 0.56 / p = 0.007, and ESV - r = -0.45 / p = 0.026. Percentage maximal peak VO2 attained correlated with LA dimensions measured in 2D echo and after dobutamine (r = -0.398 / p = 0.036 and r = -0.674 / p = 0.02 respectively) and EF after dobutamine (r = -0.389 / p = 0.04). The value of pro-BNP correlated with LA dimensions and baseline EF (r = 0.44 / p = 0.02 and r = -0.57 / p = 0.002, respectively), and the correlation was maintained after inotropic stimulation with dobutamine (r = 0.57 / p = 0.001 and r = -0.55 / p = 0.0039). CONCLUSION: Low-dose dobutamine stress echocardiography showed stronger correlations with cardiopulmonary exercise testing than the parameters evaluated by conventional echocardiography and could be used to determine the functional status of patients with dilated cardiomyopathy; patients with greater ejection fraction after inotropic stimulation had better cardiopulmonary tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION AND OBJECTIVES: Recurrent syncope has a significant impact on quality of life. The development of measurement scales to assess this impact that are easy to use in clinical settings is crucial. The objective of the present study is a preliminary validation of the Impact of Syncope on Quality of Life questionnaire for the Portuguese population. METHODS: The instrument underwent a process of translation, validation, analysis of cultural appropriateness and cognitive debriefing. A population of 39 patients with a history of recurrent syncope (>1 year) who underwent tilt testing, aged 52.1 ± 16.4 years (21-83), 43.5% male, most in active employment (n=18) or retired (n=13), constituted a convenience sample. The resulting Portuguese version is similar to the original, with 12 items in a single aggregate score, and underwent statistical validation, with assessment of reliability, validity and stability over time. RESULTS: With regard to reliability, the internal consistency of the scale is 0.9. Assessment of convergent and discriminant validity showed statistically significant results (p<0.01). Regarding stability over time, a test-retest of this instrument at six months after tilt testing with 22 patients of the sample who had not undergone any clinical intervention found no statistically significant changes in quality of life. CONCLUSIONS: The results indicate that this instrument is of value for assessing quality of life in patients with recurrent syncope in Portugal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Patient-controlled epidural analgesia with low concentrations of anesthetics is effective in reducing labor pain. The aim of this study was to assess and compare two ultra-low dose regimens of ropivacaine and sufentanil (0.1% ropivacaine plus 0.5 μg.ml-1 sufentanil vs. 0.06% ropivacaine plus 0.5 μg.ml-1 sufentanil) on the intervals between boluses and the duration of labor. MATERIAL AND METHODS: In this non-randomized prospective study, conducted between January and July 2010, two groups of parturients received patient-controlled epidural analgesia: Group I (n = 58; 1 mg.ml-1 ropivacaine + 0.5 μg.ml-1 sufentanil) and Group II (n = 57; 0.6 mg.ml-1 ropivacaine + 0.5 μg.ml-1 sufentanil). Rescue doses of ropivacaine at the concentration of the assigned group without sufentanil were administered as necessary. Pain, local anesthetic requirements, neuraxial blockade characteristics, labor and neonatal outcomes, and maternal satisfaction were recorded. RESULTS: The ropivacaine dose was greater in Group I (9.5 [7.7-12.7] mg.h-1 vs. 6.1 [5.1-9.8 mg.h-1], p < 0.001). A time increase between each bolus was observed in Group I (beta = 32.61 min, 95% CI [25.39; 39.82], p < 0.001), whereas a time decrease was observed in Group II (beta = -1.40 min, 95% CI [-2.44; -0.36], p = 0.009). The duration of the second stage of labor in Group I was significantly longer than that in Group II (78 min vs. 65 min, p < 0.001). CONCLUSIONS: Parturients receiving 0.06% ropivacaine exhibited less evidence of cumulative effects and exhibited faster second stage progression than those who received 0.1% ropivacaine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To assess the degree of discomfort caused by length measurement in neonates, performed with one or both lower limbs extended, on the first and second day after birth, with either one or both lower limbs extended. METHODS: Healthy full-term neonates were systematically sampled during the months of February and March 2004. Crown-heel length was measured, using a 1-mm precision neonatometer, at approximately 8 h and 32 h after birth, with one and both lower limbs extended. The Neonatal Facial Coding System was used to assess discomfort during measurements. Data were analysed by parametric and non-parametric tests as appropriate. RESULTS: Whatever the measurement technique, discomfort scores are significantly higher during the length measurement than at baseline. Whenever length measurements are performed, discomfort scores are significantly higher when extending both lower limbs rather than one lower limb (p < 0.006). The measured length is greater with one lower limb extended; however, the difference decreases over time, being 0.19 cm (95% CI 0.1-0.3; p < 0.001) at approximately 32 h of age. No significant differences in length were found between measurements at approximately 8 or 32 h, regardless of the technique used. The best correlation between length measurements with one or both lower limbs extended was observed at approximately 32 h after birth (r = 0.98). CONCLUSION: Measuring crown-heel length is a distressful procedure for the neonate. Measurements with one lower limb extended result in less discomfort than when both lower limbs are extended, without decreasing the accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Left ventricular reverse remodeling (LVRR), defined as reduction of end-diastolic and end-systolic dimensions and improvement of ejection fraction, is associated with the prognostic implications of cardiac resynchronization therapy (CRT). The time course of LVRR remains poorly characterized. Nevertheless, it has been suggested that it occurs ≤6 months after CRT. OBJECTIVE: To characterize the long-term echocardiographic and clinical evolution of patients with LVRR occurring >6 months after CRT and to identify predictors of a delayed LVRR response. METHODS: A total of 127 consecutive patients after successful CRT implantation were divided into three groups according to LVRR response: Group A, 19 patients (15%) with LVRR after >6 months (late LVRR); Group B, 58 patients (46%) with LVRR before 6 months (early LVRR); and Group C, 50 patients (39%) without LVRR during follow-up (no LVRR). RESULTS: The late LVRR group was older, more often had ischemic etiology and fewer patients were in NYHA class ≤II. Overall, group A presented LVRR between group B and C. This was also the case with the percentage of clinical response (68.4% vs. 94.8% vs. 38.3%, respectively, p<0.001), and hospital readmissions due to decompensated heart failure (31.6% vs. 12.1% vs. 57.1%, respectively, p<0.001). Ischemic etiology (OR 0.044; p=0.013) and NYHA functional class