8 resultados para MONITOR


Relevância:

20.00% 20.00%

Publicador:

Resumo:

When using the useful 2013 Fenton Chart, data should be interpreted with caution taking into account two aspects: the physiologic loss of body water after birth for the weight curves, and the questionable accuracy of the birth length curves considering the heterogeneity and reliability of the methods used in the original measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Está demonstrado o papel do teste de inclinação na avaliação de doentes com síncope de causa não esclarecida, sendo utilizado como a técnica gold standard para o diagnóstico da síncope neurocardiogénica, em particular com o recurso a agentes provocativos farmacológicos de modo a melhorar a acuidade diagnóstica. A estimulação com nitroglicerina sub-lingual é, regra geral, bem tolerada e permite aumentar a sensibilidade do teste reduzindo a sua duração. Neste sentido, tem-se verificado também o alargamento da sua aplicação em doentes idosos. Objectivos: Avaliar, numa população referenciada por síncope de etiologia desconhecida, a utilidade do teste de inclinação com recurso a nitroglicerina sub-lingual e comparar o tipo de respostas obtidas nos doentes idosos com o dos restantes doentes. Métodos: Estudámos 158 doentes submetidos a teste de inclinação com utilização de nitroglicerina como agente provocativo. Foram considerados doentes com idade <65 anos (Grupo A, n=74) e ≥65 anos (Grupo B, n=84). O teste de inclinação foi efectuado segundo o protocolo “italiano”, sob monitorização contínua do electrocardiograma e da tensão arterial (Task Force Monitor; CNSystems). Foram incluídos somente doentes assintomáticos na fase passiva do teste. O teste foi considerado positivo para resposta neurocardiogénica quando houve reprodução da sintomatologia acompanhada de bradicardia e/ou hipotensão arterial e as respostas foram definidas como cardio-inibitória, vasodepressora ou mista. Uma descida gradual e paralela da tensão arterial após administração de nitroglicerina seguida de síncope foi considerada como resposta exagerada aos nitratos. Resultados: Não se verificam diferenças na distribuição por sexos entre os grupos. O teste de inclinação foi positivo em 57% do Grupo A e 51% do Grupo B (p=NS), tendo ocorrido resposta exagerada aos nitratos em 11% e 16%, respectivamente (p=NS). Relativamente ao tipo de respostas neurocardiogénicas, as vasodepressoras foram mais frequentes no Grupo B (53% versus 24%; p=0,001) e as mistas tendencialmente mais frequentes no Grupo A (59% versus 40%; p=0,07), sem diferenças significativas no que se refere à resposta do tipo cardio-inibitória (17% nos Grupo A versus 7% no Grupo B; p=NS). Conclusões: Numa população com síncope de etiologia não conhecida, o teste de inclinação potenciado pela nitroglicerina: a) contribui de modo significativo para o esclarecimento diagnóstico com utilidade idêntica em idosos e nos restantes doentes. B) associa-se a maior incidência de resposta neurocardiogénica vasodepressora nos idosos embora com uma taxa semelhante de respostas exageradas aos nitratos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The autonomic nervous system (ANS) plays a role as a modulator in the pathogenesis of paroxysmal atrial fibrillation (PAF). The clinical pattern of vagally mediated PAF has been observed mainly in young patients. Neurocardiogenic responses during orthostatic stress are related to autonomic reflexes in which the vagal influence predominates. AIM: To evaluate the susceptibility of elderly patients with PAF to activation of vasovagal syncope mechanisms. METHODS: We performed passive head-up tilt testing (HUT) in 34 patients (62% women, aged 72 +/- 7 years), with > or = 1 year of clinical history of PAF--19 without structural heart disease, 11 with hypertensive heart disease and 4 with coronary artery disease (who had no previous myocardial infarction, had undergone myocardial revascularization, and had no documented ischemia) (PAF group), and compared the results with those obtained in a group of 34 age-matched patients (53% women, aged 74 +/- 6 years), who underwent HUT due to recurrent syncope (Sc group). In this group, 21 had no documented heart disease and none had a clinical history of AF. There was no diabetes, congestive heart failure or syncope in the PAF group. After a supine resting period, the subjects were tilted at 70 degrees for 20 minutes while in sinus rhythm. No provocative agents were used to complement the HUT. ECG and blood pressure were continuously monitored (Task Force Monitor, CNSystems). The test was considered positive when syncope or presyncope occurred with bradycardia and/or arterial hypotension. Abnormal responses were classified as cardioinhibitory, vasodepressor or mixed. RESULTS: HUT was positive in seven patients of the PAF group--vasodepressor response in five and mixed in two (20.5% of the total; 26.3% of those without heart disease)--and in eight patients (vasodepressor in six and mixed in two) of the Sc group (p=NS). During HUT, three patients of the PAF group had short periods of self-limited PAF (in one, after vasodepressor syncope). There were no differences in gender distribution, age or heart disease. No cardioinhibitory responses or orthostatic hypotension were observed. CONCLUSION: In elderly patients with PAF, a significant number of false positive results during passive HUT may be expected, suggesting increased vasovagal reactions despite aging. This suggests that ANS imbalances may be observed in this population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The autonomic nervous system (ANS) is known to be an important modulator in the pathogenesis of paroxysmal atrial fibrillation (PAF). Changes in ANS control of heart rate variability (HRV) occur during orthostatism to maintain cardiovascular homeostasis. Wavelet transform has emerged as a useful tool that provides time-frequency decomposition of the signal under investigation, enabling intermittent components of transient phenomena to be analyzed. AIM: To study HRV during head-up tilt (HUT) with wavelet transform analysis in PAF patients and healthy individuals (normals). METHODS: Twenty-one patients with PAF (8 men; age 58 +/- 14 yrs) were examined and compared with 21 normals (7 men, age 48 +/- 12 yrs). After a supine resting period, all subjects underwent passive HUT (60 degrees) while in sinus rhythm. Continuous monitoring of ECG and blood pressure was carried out (Task Force Monitor, CNSystems). Acute changes in RR-intervals were assessed by wavelet analysis and low-frequency power (LF: 0.04-0.15 Hz), high-frequency power (HF: 0.15-0.60 Hz) and LF/HF (sympathovagal) were calculated for 1) the last 2 min of the supine period; 2) the 15 sec of tilting movement (TM); and 3) the 1st (TT1) and 2nd (TT2) min of HUT. Data are expressed as means +/- SEM. RESULTS: Baseline and HUT RR-intervals were similar for the two groups. Supine basal blood pressure was also similar for the two groups, with a sustained increase in PAF patients, and a decrease followed by an increase and then recovery in normals. Basal LF, HF and LF/ HF values in PAF patients were 632 +/- 162 ms2, 534 +/- 231 ms2 and 1.95 +/- 0.39 respectively, and 1058 +/- 223 ms2, 789 +/- 244 ms2 and 2.4 +/- 0.36 respectively in normals (p = NS). During TM, LF, HF and LF/HF values for PAF patients were 747 +/- 277 ms2, 387 +/- 94 ms2 and 2.9 +/- 0.6 respectively, and 1316 +/- 315 ms2, 698 +/- 148 ms2 and 2.8 +/- 0.6 respectively in normals (p < 0.05 for LF and HF). During TF1, LF, HF and LF/ HF values for PAF patients were 1243 +/- 432 ms2, 302 +/- 88 ms2 and 7.7 +/- 2.4 respectively, and 1992 +/- 398 ms2, 333 +/- 76 ms2 and 7.8 +/- 0.98 respectively for normals (p < 0.05 for LF). During TF2, LF, HF and LF/HF values for PAF patients were 871 +/- 256 ms2, 242 +/- 51 ms2 and 4.7 +/- 0.9 respectively, and 1263 +/- 335 ms2, 317 +/- 108 ms2 and 8.6 +/- 0.68 respectively for normals (p < 0.05 for LF/HF). The dynamic profile of HRV showed that LF and HF values in PAF patients did not change significantly during TM or TT2, and LF/HF did not change during TM but increased in TT1 and TT2. CONCLUSION: Patients with PAF present alterations in HRV during orthostatism, with decreased LF and HF power during TM, without significant variations during the first minutes of HUT. These findings suggest that wavelet transform analysis may provide new insights when assessing autonomic heart regulation and highlight the presence of ANS disturbances in PAF.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Clopidogrel is frequently associated with thrombotic thrombocytopenic purpura, however this drug is rarely related to severe isolated thrombocytopenia. Pentoxifylline has previously been associated with thrombocytopenia only once. To the best of our knowledge, this is the first report of severe isolated thrombocytopenia after therapy with both clopidogrel and pentoxyfilline. CASE PRESENTATION: We report the case of a 79-year-old Caucasian man who presented to our facility with intermittent claudication. He had obliterative arterial disease and started therapy with clopidogrel and pentoxifylline. His basal platelet count was 194 × 109 cells/L. At three days after the start of treatment, our patient had lower limb petechia and stopped taking clopidogrel and pentoxifylline. His platelet count lowered to 4 × 109 cells/L and our patient was admitted to hospital. Our patient had purpura with no other hemorrhages or splenomegaly. Results of a blood smear were normal, and a bone marrow study showed dysmegakaryopoiesis. Antiplatelet antibody test results were negative, as were all viral serology tests. Imaging study results were normal. Our patient was given immunoglobulin but there was no sustained platelet increase, so corticotherapy was started as the next treatment step. At five months after clopidogrel and pentoxifylline were discontinued, his platelet count continued increasing even after prednisolone was tapered. CONCLUSIONS: Severe isolated thrombocytopenia may appear as a side effect when using clopidogrel and pentoxifylline. These drugs are widely used by general physicians, internists, cardiologists and vascular surgeons. We hope this report will raise awareness of the need to monitor the platelet count in patients taking these drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectivos: Com a generalização dos procedimentos endovasculares, cresce a preocupação com os efeitos deletérios que a execução continuada de tais procedimentos radiológicos acarreta. Com este trabalho pretendeu-se avaliar e quantificar a distribuição pela equipa cirúrgica da exposição à radiação dispersa, emitida por um aparelho portátil de radioscopia com arco cirúrgico (arco em C), durante a utilização em bloco operatório. Material e métodos: O registo e avaliação da dose de radiação foram efectuados em sala do bloco operatório reproduzindo as condições habituais em que decorrem os procedimentos endovasculares. Para a simulação geométrica do tórax do doente foi utilizado um fantoma cilíndrico de polimetilmetacrilato (PMMA) com 15 cm de espessura. A radiação dispersa foi medida para o local do cirurgião, ajudante, anestesista e enfermeira instrumentista, através de um monitor de radiação portátil RaySafe Xi Survey Detector, tendo sido ajustada a medição para a avaliação da taxa de dose de exposição à radiação em mGy/s a diversas alturas do solo e distâncias do doente. Utilizou-se ainda o detetor RaySafe Xi R/F para a medição da taxa de dose de exposição na superfície de entrada da pele do doente. As medições foram efectuadas em modo de fl uoroscopia pulsada de 4 quadros por segundo (qps), subtração digital e roadmap, com a combinação dos três modos de magnifi cação electrónica disponíveis (Mag1, Mag2 e Mag3). Em todos os casos foi considerada a Dose 3, o nível de dose máxima do aparelho que fornece a melhor qualidade de imagem através do controlo automático em tempo real do contraste e do brilho. Resultados: A análise dos dados permitiu determinar a distribuição da radiação dispersa pela equipa assistente, constatando-se como nível máximo de exposição, a altura ao solo de 120 cm no modo de subtracção digital e roadmap. A este nível, a intensidade da radiação dispersa em relação à taxa de dose de exposição na superfície de entrada da pele do doente é distribuída em 0,47% pelo cirurgião, 0,21% pelo anestesista, 0,32% pelo ajudante e 0,13% pela enfermeira instrumentista. A utilização de subtração digital e roadmap aumentou o nível de radiação cerca de 5 vezes em relação à fluoroscopia pulsada a 4 qps, tanto na taxa de dose de exposição na superfície de entrada da pele do doente como na radiação dispersa pela equipa. Quando utilizados os meios de proteção radiológica os níveis de radiação foram consideravelmente inferiores. Conclusões: Atendendo à dispersão prevista da radiação determinou-se que a proximidade da ampola aumenta a quantidade de radiação dispersa que atinge o corpo. Quando utilizado o equipamento de proteção individual, os níveis de radiação dispersa são consideravelmente menores e permitem doses acumuladas abaixo dos limites aceitáveis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Surveillance registers monitor the prevalence of cerebral palsy and the severity of resulting impairments across time and place. The motor disorders of cerebral palsy can affect children’s speech production and limit their intelligibility. We describe the development of a scale to classify children’s speech performance for use in cerebral palsy surveillance registers, and its reliability across raters and across time. Speech and language therapists, other healthcare professionals and parents classified the speech of 139 children with cerebral palsy (85 boys, 54 girls; mean age 6.03 years, SD 1.09) from observation and previous knowledge of the children. Another group of health professionals rated children’s speech from information in their medical notes. With the exception of parents, raters reclassified children’s speech at least four weeks after their initial classification. Raters were asked to rate how easy the scale was to use and how well the scale described the child’s speech production using Likert scales. Inter-rater reliability was moderate to substantial (k > .58 for all comparisons). Test–retest reliability was substantial to almost perfect for all groups (k > .68). Over 74% of raters found the scale easy or very easy to use; 66% of parents and over 70% of health care professionals judged the scale to describe children’s speech well or very well. We conclude that the Viking Speech Scale is a reliable tool to describe the speech performance of children with cerebral palsy, which can be applied through direct observation of children or through case note review.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: A simulação possibilita o ensino e treino de técnicas de suporte de vida complexas sem riscos para o doente. Até ao momento, as únicas opções de treino no manuseamento de terapêuticas de depuração extra-renal contínua (TDEC) eram a aprendizagem directa em doentes submetidos a esta técnica ou mediante observação dos efeitos da manipulação do circuito não conectado ao doente. Por este motivo foi elaborado um simulador de TDEC, usado em cursos de simulação realizados para treino de equipas de cuidados intensivos pediátricos (UCIP). Objectivos: Analisar a performance e utilidade de um novo simulador que possibilita o controlo externo do dispositivo de TDEC, simulando "in situ" cenários que mimetizam condições de doentes tratados com TDEC. Métodos: Foi criado um dispositivo que, uma vez conectado ao aparelho de TDEC, permite o controlo em tempo real de todas as pressões de hemofiltração, de acordo com as condições clínicas e acções dos participantes. Foram simulados diversos cenários e complicações possíveis em doentes submetidos a estas técnicas e avaliada a performance deste dispositivo "in vitro". A satisfação dos participantes foi avaliada mediante a aplicação de um inquérito. Resultados: Foram realizados 4 cursos de TDEC de Maio de 2009 a Março de 2012. Incluídos 60 participantes, todos com experiência clínica prévia em UCIP. Realizados 32 cenários, abrangendo complicações relacionados com o cateter, coagulação dos filtros e ajuste inadequado dos parâmetros de hemofiltração. Nos cenários simulados, o dispositivo simulador permitiu, em tempo real, mudanças simples e rápidas nas pressões do monitor de TDEC e em resposta às atitudes tomadas pelos participantes para a sua resolução. Não foram registadas intercorrências relacionadas com disfunção do dispositivo. Os participantes consideraram-no muito útil como ferramenta de aprendizagem activa, permitindo uma gestão realista das condições clínicas simuladas, com potencial impacto sobre a sua futura prática diária. Os instrutores consideraram-no fácil de manusear e realista. Conclusões: Este simulador permite uma simulação mais fidedigna dos cenários de TDEC, resolvendo o problema da interferência do instrutor no cenário simulado. Este poderia melhorar as capacidades dos simuladores de alta fidelidade disponíveis e utilizar-se como uma ferramenta docente na formação de profissionais de saúde.