3 resultados para Gold Catalyst, Formaldehyde Oxidation, Indoor Air Pollution, Ceria Support, TEM Analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Poor ventilation at day care centres (DCCs) was already reported, although its effects on attending children are not clear. This study aimed to evaluate the association between wheezing in children and indoor CO2 (a ventilation surrogate marker) in DCC and to identify behaviours and building characteristics potentially related to CO2. In phase I, 45 DCCs from Lisbon and Oporto (Portugal) were selected through a proportional stratified random sampling. In phase II, 3 months later, 19 DCCs were further reassessed after cluster analysis for the greatest difference comparison. In both phases, children’s respiratory health was assessed by ISAAC-derived questionnaires. Indoor CO2 concentrations and building characteristics of the DCC were evaluated in both phases, using complementary methods. Mixed effect models were used to analyze the data. In phase I, which included 3,186 children (mean age 3.1±1.5 years), indoor CO2 concentration in the DCC rooms was associated with reported wheezing in the past 12months (27.5 %) (adjusted odds ratio (OR) for each increase of 200 ppm 1.04, 95 % CI 1:01 to 1:07). In phase II, the association in the subsample of 1,196 children seen in 19 out of the initial 45 DCCs was not significant (adjusted OR 1.02, 95 % CI 0.96 to 1.08). Indoor CO2 concentration was inversely associated with the practices of opening Windows and internal doors and with higher wind velocity. A positive trend was observed between CO2 and prevalence of reported asthma (4.7 %). Conclusion: Improved ventilation is needed to achieve a healthier indoor environment in DCC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Indoor air quality (IAQ) is considered an important determinant of human health. The association between exposure to volatile organic compounds, particulate matter, house dust mite, molds and bacteria in day care centers (DCC) is not completely clear. The aim of this project was to study these effects. Methods --- study design: This study comprised two phases. Phase I included an evaluation of 45 DCCs (25 from Lisbon and 20 from Oporto, targeting 5161 children). In this phase, building characteristics, indoor CO2 and air temperature/relative humidity, were assessed. A children’s respiratory health questionnaire derived from the ISAAC (International Study on Asthma and Allergies in Children) was also distributed. Phase II encompassed two evaluations and included 20 DCCs selected from phase I after a cluster analysis (11 from Lisbon and 9 from Oporto, targeting 2287 children). In this phase, data on ventilation, IAQ, thermal comfort parameters, respiratory and allergic health, airway inflammation biomarkers, respiratory virus infection patterns and parental and child stress were collected. Results: In Phase I, building characteristics, occupant behavior and ventilation surrogates were collected from all DCCs. The response rate of the questionnaire was 61.7% (3186 children). Phase II included 1221 children. Association results between DCC characteristics, IAQ and health outcomes will be provided in order to support recommendations on IAQ and children’s health. A building ventilation model will also be developed. Discussion: This paper outlines methods that might be implemented by other investigators conducting studies on the association between respiratory health and indoor air quality at DCC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introdução: A asma é uma doença respiratória crónica, cujo agravamento pode estar associado a factores ambientais, entre os quais os relacionados com a qualidade do ar. Objectivo: O presente trabalho pretendeu avaliar o efeito da exposição individual a poluentes atmosféricos em termos de função respiratória, num grupo de crianças com história de sibilância, entrando em consideração com o grau de infestação de ácaros do pó doméstico. Métodos: Um grupo de 51 crianças com história de sibilância, seleccionadas através do questionário do estudo ISAAC, foi acompanhado prospectivamente num estudo com medidas repetidas, que envolveu avaliações médicas padronizadas que incluíram a realização de espirometria, avaliação da exposição aos ácaros do pó e cálculo do valor de exposição individual a uma variedade de poluentes do ar: PM10, O3, NO2, benzeno, tolueno, xileno, etilbenzeno e formaldeído. Resultados: Observou -se uma elevada percentagem de colchões com um grau de infestação de ácaros médio ou elevado. Com excepção dos valores de PM10, os valores de exposição aos poluentes do ar não alcançaram valores elevados. Na análise multivariável, tanto os poluentes (designadamente PM10, NO2, benzeno, tolueno e etilbenzeno) como o grau de infestação de ácaros do pó associaram -se a deterioração da função pulmonar. Conclusão: O presente trabalho vem reforçar o interesse da exposição aos poluentes do ar em crianças com história de sibilância, que à semelhança do que acontece com os ácaros do pó influenciam as vias aéreas.