3 resultados para FIRE PERFORMANCE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessment of surgical performance is a must for every surgical practice nowadays and can be done by using scientific methods imported mostly from the Quality control tools that have been in use for long in industry. Surgical performance comprises several dimensions including clinical activity (mortality and morbidity as end points), academic activities, research and, more and more, efficiency. Stable long time results (efficacy), reducing error (safety) and meeting patient expectations (patient satisfaction) are among other performance components. This paper focus on the precise definitions of mortality and morbidity related to surgical activities and on the tools to evaluate patient complexity and assess pre operative risk. Some graphic representations are suggested to compare performance profiles of surgeons and to define individual performance profiles. Strong emphasis is put on pre operative risk assessment and its crucial role to interpret divergent surgical results. Where risk assessment is not possible or is unavailable, observed / expected ratios (O/E) for a given endpoint , be it mortality, length of stay or morbidity, must be established and routinely used to refer results and to identify performance outliers. Morbidity is being pointed out as a most valuable performance indicator in surgery because it is sensitive and comprises efficiency, safety and quality, at large.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Sexually transmitted infections (STIs) present a major public health concern and a global cause of illness in both industrialized and developing countries. Portugal is no exception, with an increasing incidence of STIs, and one of the highest prevalences of HIV in Europe. Reduced risk perceptions among men who have sex with men (MSM) and a consequent high-risk sexual behaviour have been increasingly reported throughout the world. Objectives: To characterize the population of MSM attending a STI clinic in Lisbon, and to assess practice of condom use among these patients. Methods: Records of all MSM patients who attended the STI clinic from 2008 to 2011 were reviewed to study demographic characteristics, sexual behaviours, and leading diagnoses in this population. Results: Of a total of 389 patients, 108 MSM were identified (27.8%), mostly Portuguese men with high school or above education, aged 17 to 61 years (medium age of 32.4 years). More than half of the patients (52.8%) reported more than one sexual partner in the past 6 months (19.4% more than 5 partners), and only a third consistently used condom. A history of sex with sex workers was mentioned in 9.2%. The most prevalent diagnoses were syphilis (45.6%) and condylomata acuminata (38.9%). The prevalence of HIV infection in this subgroup of patients was significantly higher than in the rest of the population (47.2% vs. 14.9%). Inconsistent condom use increased over the years (36.4% in 2008, 66.7% in 2011), and these patients revealed a greater number of sexual partners than condom users (60.4% vs. 50%). However, 38.9% of condom users presented with early syphilis, suggesting inadequate use of this barrier method. Among HIV patients, almost half of them (49%) had sex with more than one partner in the previous six months, and 47.1% did not use the condom during all sexual practices. Of these, 45.8% were not on antiretroviral therapy. Conclusions: High-risk sexual behaviours (inconsistent use of condom and multiple partners) are increasingly prevalent in this MSM subpopulation, despite previous educational programmes. The high incidence of risk behaviours among HIV infected patients is particularly worrisome, and must be addressed with innovative interventions and population-based prevention strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modelling of ventilation is strongly dependent on the physical characteristics of the building of which precise evaluation is a complex and time consuming task. In the frame of a research project, two children day care centres (CDCC) have been selected in order to measure the envelope air permeability, the flow rate of mechanical ventilation systems and indoor and outdoor temperature. The data obtained was used as input to the computer code CONTAM for ventilation simulations. The results obtained were compared with direct measurements of ventilation flow from short term measurements with CO2 tracer gas and medium term measurements with perfluorocarbon tracer (PFT) gas decay method. After validation, in order to analyse the main parameters that affect ventilation, the model was used to predict the ventilation rates for a wide range of conditions. The purpose of this assessment was to find the best practices to improve natural ventilation. A simple analytical method to predict the ventilation flow rate of rooms is also presented. The method is based on the estimation of wind effect on the room through the evaluation of an average factor and on the assessment of relevant cross section of gaps and openings combined in series or in parallel. It is shown that it may be applied with acceptable accuracy for this type of buildings when ventilation is due essentially to wind action.