4 resultados para Efficiency Tests


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Skin testing remains an essential diagnostic tool in modern allergy practice. A signifi cant variability has been reported regarding technical procedures, interpretation of results and documentation. This review has the aim of consolidating methodological recommendations through a critical analysis on past and recent data. This will allow a better understanding on skin prick test (SPT) history; technique; (contra-) indications; interpretation of results; diagnostic pitfalls; adverse reactions; and variability factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: A growing body of evidence shows the prognostic value of oxygen uptake efficiency slope (OUES), a cardiopulmonary exercise test (CPET) parameter derived from the logarithmic relationship between O(2) consumption (VO(2)) and minute ventilation (VE) in patients with chronic heart failure (CHF). OBJECTIVE: To evaluate the prognostic value of a new CPET parameter - peak oxygen uptake efficiency (POUE) - and to compare it with OUES in patients with CHF. METHODS: We prospectively studied 206 consecutive patients with stable CHF due to dilated cardiomyopathy - 153 male, aged 53.3±13.0 years, 35.4% of ischemic etiology, left ventricular ejection fraction 27.7±8.0%, 81.1% in sinus rhythm, 97.1% receiving ACE-Is or ARBs, 78.2% beta-blockers and 60.2% spironolactone - who performed a first maximal symptom-limited treadmill CPET, using the modified Bruce protocol. In 33% of patients an cardioverter-defibrillator (ICD) or cardiac resynchronization therapy device (CRT-D) was implanted during follow-up. Peak VO(2), percentage of predicted peak VO(2), VE/VCO(2) slope, OUES and POUE were analyzed. OUES was calculated using the formula VO(2) (l/min) = OUES (log(10)VE) + b. POUE was calculated as pVO(2) (l/min) / log(10)peakVE (l/min). Correlation coefficients between the studied parameters were obtained. The prognosis of each variable adjusted for age was evaluated through Cox proportional hazard models and R2 percent (R2%) and V index (V6) were used as measures of the predictive accuracy of events of each of these variables. Receiver operating characteristic (ROC) curves from logistic regression models were used to determine the cut-offs for OUES and POUE. RESULTS: pVO(2): 20.5±5.9; percentage of predicted peak VO(2): 68.6±18.2; VE/VCO(2) slope: 30.6±8.3; OUES: 1.85±0.61; POUE: 0.88±0.27. During a mean follow-up of 33.1±14.8 months, 45 (21.8%) patients died, 10 (4.9%) underwent urgent heart transplantation and in three patients (1.5%) a left ventricular assist device was implanted. All variables proved to be independent predictors of this combined event; however, VE/VCO2 slope was most strongly associated with events (HR 11.14). In this population, POUE was associated with a higher risk of events than OUES (HR 9.61 vs. 7.01), and was also a better predictor of events (R2: 28.91 vs. 22.37). CONCLUSION: POUE was more strongly associated with death, urgent heart transplantation and implantation of a left ventricular assist device and proved to be a better predictor of events than OUES. These results suggest that this new parameter can increase the prognostic value of CPET in patients with CHF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Few studies have been performed in children withs uspected betalactam allergy.We aimed to assess the role of the drug provocation test(DPT)with betalactams in a paediatric setting and to study the association between allergy to betalactam antibiotics and other allergic diseases. Methods:We included all the patients under 15 years old who were consecutively referred to the Immunoallergy Department, Dona Estefânia Hospital,Portugal(January 2002 to April 2008)for a compatible history of allergic reaction to betalactam. All were submitted to a DPT.Children were proposed to performs kintests(ST)to betalactam antibiotics followed by DPT. If they decline ST,a DPT with the culprit drug was performed. Results: We studied 161 children,60%were boys,with a median age of 5years old at the time of the DPT.Thirty-three patients(20.5%)had an immediate reaction and 33(20.5%)a non-immediate reaction. These verity of there porte dreactions was low in most cases. Skin tests to betalactams were performed in 47 children and were positive in 8.DPT was positive inonlyone(3.4%)of the patients skin tested and in 11(13.4%)of those not skin tested. These verity of the DPT reaction was low.Asthma and food allergy were associated with a positive DPT in the later group. Conclusions: DPT seems a safe procedure even in the absence of ST in non-severe cases. This could be a practical optionin infants and pre-school children,where ST are painful and difficult to perform.Additional caution should be taken in children with asthma and food allergy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine whether the slope of a maximal bronchial challenge test (in which FEV1 falls by over 50%) could be extrapolated from a standard bronchial challenge test (in which FEV1 falls up to 20%), 14 asthmatic children performed a single maximal bronchial challenge test with methacholin(dose range: 0.097–30.08 umol) by the dosimeter method. Maximal dose-response curves were included according to the following criteria: (1) at least one more dose beyond a FEV1 ù 20%; and (2) a MFEV1 ù 50%. PD20 FEV1 was calculated, and the slopes of the early part of the dose-response curve (standard dose-response slopes) and of the entire curve (maximal dose-response slopes) were calculated by two methods: the two-point slope (DRR) and the least squares method (LSS) in % FEV1 × umol−1. Maximal dose-response slopes were compared with the corresponding standard dose-response slopes by a paired Student’s t test after logarithmic transformation of the data; the goodness of fit of the LSS was also determined. Maximal dose-response slopes were significantly different (p < 0.0001) from those calculated on the early part of the curve: DRR20% (91.2 ± 2.7 FEV1% z umol−1)was 2.88 times higher than DRR50% (31.6 ± 3.4 DFEV1% z umol−1), and the LSS20% (89.1 ± 2.8% FEV1 z umol−1) was 3.10 times higher than LSS 50% (28.8 ± 1.5%FEV1 z umol−1). The goodness of fit of LSS 50% was significant in all cases, whereas LSS 20% failed to be significant in one. These results suggest that maximal dose-response slopes cannot be predicted from the data of standard bronchial challenge tests.