5 resultados para Design procedure
Resumo:
Overview and Aims: Female sterilization is increasingly requested as a contraceptive method. Hysteroscopic sterilization by transcervical placing of Essure® micro-inserts in the initial portion of the tubes is a recent alternative to laparoscopic sterilization. The objective of this study is to evaluate the safety and effectiveness of hysteroscopic versus laparoscopic sterilization. Study Design: Retrospective cohort study. Population: A total of 98 women undergoing sterilization in an outpatient clinic between July 2005 and July 2009. Methods: Patients’ age, associated diseases, anesthesic risk, procedure time, discomfort, adverse events and success rate were evaluated. Results: Mean age at surgery was 37.8 years (19-49), and there were no statistically significant differences between the groups regarding this parameter. Women in the hysteroscopic group had a significant number of associated diseases (98% versus 47%), obesity (31% versus 6%), and anesthesic risk (ASA III- 31% versus 0%). The mean duration of the procedure was the same for both techniques (laparoscopy 28 minutes and hysteroscopy 26 minutes). All laparoscopic sterilizations were successfully completed. In the hysteroscopic group 4% failed to complete the technique. There were no cases of severe pain. Women in the hysteroscopy group reported pain less frequently (40% versus 57%, χ2 p<0.05). Long term success rate was similar in both groups (96% for hysteroscopy and 98% for laparoscopy). Conclusions: In spite of a higher incidence of associated diseases, obesity and anesthetic risks in the hysteroscopy group, there were no significant differences in the duration of the procedure, adverse events and success rate. The hysteroscopic approach can therefore be considered an alternative to laparoscopy, eliminating the need for incisional surgery and for general anaesthesia. If women with high surgical risk and several associated diseases can safely undergo this procedure, it could well become the preferred method for women who want a permanent and irreversible contraceptive method.
Resumo:
Background: Performing magnetic resonance imaging (MRI) on women with gynecological devices is a completely accepted practice. The goal of our review is to assess how safe it is to perform MRI on women using contraceptive implants or devices. Study Design: Literature review, searching in PubMed-Medline/Ovid for the following keywords: magnetic resonance imaging, intrauterine devices, Implanon® and Essure®. Results: Though plastic devices do not represent a contraindication to the use of the technique, those including metallic components have been submitted to several tests, after which they were classified as MR Conditional (devices presenting no risks in MR-specific environments) by the Food and Drug Administration. Thus, the use of MRI can be safely advised to women with this type of device as long as the magnetic resonance equipment is ≤3.0 T. Conclusions: Presently, there is no scientific evidence that contraindicates performing MRI on women with any kind of gynecological device. Therefore, this procedure is safe as long as it is performed under previously tested conditions.
Resumo:
OBJECTIVE: The objective of the study was to develop a model for estimating patient 28-day in-hospital mortality using 2 different statistical approaches. DESIGN: The study was designed to develop an outcome prediction model for 28-day in-hospital mortality using (a) logistic regression with random effects and (b) a multilevel Cox proportional hazards model. SETTING: The study involved 305 intensive care units (ICUs) from the basic Simplified Acute Physiology Score (SAPS) 3 cohort. PATIENTS AND PARTICIPANTS: Patients (n = 17138) were from the SAPS 3 database with follow-up data pertaining to the first 28 days in hospital after ICU admission. INTERVENTIONS: None. MEASUREMENTS AND RESULTS: The database was divided randomly into 5 roughly equal-sized parts (at the ICU level). It was thus possible to run the model-building procedure 5 times, each time taking four fifths of the sample as a development set and the remaining fifth as the validation set. At 28 days after ICU admission, 19.98% of the patients were still in the hospital. Because of the different sampling space and outcome variables, both models presented a better fit in this sample than did the SAPS 3 admission score calibrated to vital status at hospital discharge, both on the general population and in major subgroups. CONCLUSIONS: Both statistical methods can be used to model the 28-day in-hospital mortality better than the SAPS 3 admission model. However, because the logistic regression approach is specifically designed to forecast 28-day mortality, and given the high uncertainty associated with the assumption of the proportionality of risks in the Cox model, the logistic regression approach proved to be superior.
Resumo:
The ex utero intrapartum treatment is a rare surgical procedure performed in cases of expected postpartum fetal airway obstruction. The technique lies on a safe establishment of a patent airway during labor in anticipation of a critical respiratory event, without interrupting maternal-fetal circulation. Anesthetic management is substantially different from that regarding standard cesarean delivery and its main goals include uterine relaxation, fetal anesthesia and preservation of placental blood flow. We present the case of an ex utero intrapartum treatment procedure performed on a fetus with a large cervical lymphangioma and prenatal evidence of airway compromise. Modifications to the classic ex utero intrapartum treatment management strategies were successfully adopted and will be discussed in the following report.
Resumo:
INTRODUCTION: Mitral regurgitation (MR) is the most common valvular disease and has recently become the target of a number of percutaneous approaches. The MitraClip is virtually the only device for which there is considerable experience, with more than 20,000 procedures performed worldwide. OBJECTIVE: To describe our initial experience of the percutaneous treatment of MR with the MitraClip device. METHODS: We describe the first six MitraClip cases performed in this institution (mean age 58.5 ± 13.1 years), with functional MR grade 4+ and New York Heart Association (NYHA) heart failure class III or IV (n=3), with a mean follow-up of 290 ± 145 days. RESULTS: Procedural success (MR ≤ 2+) was 100%. Total procedure time was 115.8 ± 23.7 min, with no in-hospital adverse events and discharge between the fourth and eighth day, and consistent improvement in the six-minute walk test (329.8 ± 98.42 vs. 385.33 ± 106.95 m) and in NYHA class (three patients improved by two NYHA classes). During follow-up there were two deaths, in two of the four patients who had been initially considered for heart transplantation. CONCLUSION: In patients with functional MR the MitraClip procedure is safe, with both a high implantation and immediate in-hospital success rate. A longer follow-up suggests that the clinical benefit decreases or disappears completely in patients with more advanced heart disease, namely those denied transplantation or on the heart transplant waiting list.