15 resultados para Dental prosthesis repair
Resumo:
OBJECTIVE: A familial predisposition to abdominal aortic aneurysms (AAAs) is present in approximately one-fifth of patients. Nevertheless, the clinical implications of a positive family history are not known. We investigated the risk of aneurysm-related complications after endovascular aneurysm repair (EVAR) for patients with and without a positive family history of AAA. METHODS: Patients treated with EVAR for intact AAAs in the Erasmus University Medical Center between 2000 and 2012 were included in the study. Family history was obtained by written questionnaire. Familial AAA (fAAA) was defined as patients having at least one first-degree relative affected with aortic aneurysm. The remaining patients were considered sporadic AAA. Cardiovascular risk factors, aneurysm morphology (aneurysm neck, aneurysm sac, and iliac measurements), and follow-up were obtained prospectively. The primary end point was complications after EVAR, a composite of endoleaks, need for secondary interventions, aneurysm sac growth, acute limb ischemia, and postimplantation rupture. Secondary end points were specific components of the primary end point (presence of endoleak, need for secondary intervention, and aneurysm sac growth), aneurysm neck growth, and overall survival. Kaplan-Meier estimates for the primary end point were calculated and compared using log-rank (Mantel-Cox) test of equality. A Cox-regression model was used to calculate the independent risk of complications associated with fAAA. RESULTS: A total of 255 patients were included in the study (88.6% men; age 72 ± 7 years, median follow-up 3.3 years; interquartile range, 2.2-6.1). A total of 51 patients (20.0%) were classified as fAAA. Patients with fAAA were younger (69 vs 72 years; P = .015) and were less likely to have ever smoked (58.8% vs 73.5%; P = .039). Preoperative aneurysm morphology was similar in both groups. Patients with fAAA had significantly more complications after EVAR (35.3% vs 19.1%; P = .013), with a twofold increased risk (adjusted hazard ratio, 2.1; 95% confidence interval, 1.2-3.7). Secondary interventions (39.2% vs 20.1%; P = .004) and aneurysm sac growth (20.8% vs 9.5%; P = .030) were the most important elements accounting for the difference. Furthermore, a trend toward more type I endoleaks during follow-up was observed (15.6% vs 7.4%; P = .063) and no difference in overall survival. CONCLUSIONS: The current study shows that patients with a familial form of AAA develop more aneurysm-related complications after EVAR, despite similar AAA morphology at baseline. These findings suggest that patients with fAAA form a specific subpopulation and create awareness for a possible increase in the risk of complications after EVAR.
Resumo:
Children may benefit from minimally invasive surgery (MIS) in the correction of Morgagni hernia (MH). The present study aims to evaluate the outcome of MIS through a multicenter study. National institutions that use MIS in the treatment of MH were included. Demographic, clinical and operative data were analyzed. Thirteen patients with MH (6 males) were operated using similar MIS technique (percutaneous stitches) at a mean age of 22.2±18.3 months. Six patients had chromosomopathies (46%), five with Down syndrome (39%). Respiratory complaints were the most common presentation (54%). Surgery lasted 95±23min. In none of the patients was the hernia sac removed; prosthesis was never used. In the immediate post-operative period, 4 patients (36%) were admitted to intensive care unit (all with Down syndrome); all patients started enteral feeds within the first 24h. With a mean follow-up of 56±16.6 months, there were two recurrences (18%) at the same institution, one of which was repaired with an absorbable suture; both with Down syndrome. The application of MIS in the MH repair is effective even in the presence of comorbidities such as Down syndrome; the latter influences the immediate postoperative recovery and possibly the recurrence rate. Removal of hernia sac does not seem necessary. Non-absorbable sutures may be more appropriate.
Resumo:
BACKGROUND: Valve surgery in children is aimed at restoring correct hemodynamics with few reoperations and limited resort to prostheses, which would imply early deterioration or definitive hypocoagulation. OBJECTIVES: Report a series of paediatric pts with acquired mitral valve disease, mostly due to rheumatic disease, in whom it was possible, for the great majority, to repair the damaged valve. DEMOGRAPHICS: Fifty children with predominant mitral valve disease, 47 rheumatic (94%) and 3 after endocarditis were consequently operated by the same surgical team over the last five years. Ages were 12.5+/-3.1 yrs and weights 33.2+/-8.4 Kg, 30 pts presented with predominant mitral regurgitation and 20 pts had significant stenosis. In 8 pts there also moderate to severe aortic regurgitation and in 2 pts severe tricuspid regurgitation was present. Patients were not operated during the acute phase of the disease. Five pts were reoperations and from those, all but one received mechanical prosthesis. RESULTS: In all operations the intention was to repair the mitral valve. In 46 pts complex mitral valvuloplasties were performed extended comissurotomies, shortening of chordae, chordal replacement with PTFE, and reconstruction of valve leaflefts by direct patching or pericardial extension of the retracted posterior leaflet (78.2% cases), plus reshaping of the annulus by using a fixed prosthetic CE ring (sizes 26 to 32) in every case. Ring sizes correlated poorly with body weights, but correlation was close and positive for the use of pericardial advancement of the posterior leaflet (p<0.01). There was no operative mortality, but one pt died early from sepsis and there was no late mortality. Maximum follow up extends now to 50 months (median 28 months) and functional evaluation, at latest follow up, as assessed by Doppler Echocardiography, showed residual mitral regurgitation, mild-moderate in 4 pts and LA-LV gradients mild in 5 and moderate in 2 pts. NYHA functional class, at present follow-up is class I for 43 pts (88%) and class II in the remaining 6 pts. Along the follow-up period 2 pts had to be reoperated for early repair failures and other three for late failures, presently freedom for reoperation is 91.8% at 5 years. CONCLUSIONS: Mitral valve repair in children with rheumatic lesions can be achieved for the great majority of cases by using different techniques. Pericardial extension of the retracted posterior leaflet allowed the use of a bigger size prosthetic ring. Intermediate functional results are good with fair functional classes and few reoperations but follow-up is short and does not allow us to draw conclusions about the long-term results of the repair in these rheumatic patients.
Resumo:
This paper focus on the most common used prosthesis for replacement of diseased heart valves, when repair is not feasible. A brief historical review is made. New prosthesis and the trends for the future are also addressed.
Resumo:
OBJECTIVE: Long-term follow-up after endovascular aneurysm repair (EVAR) is very scarce, and doubt remains regarding the durability of these procedures. We designed a retrospective cohort study to assess long-term clinical outcome and morphologic changes in patients with abdominal aortic aneurysms (AAAs) treated by EVAR using the Excluder endoprosthesis (W. L. Gore and Associates, Flagstaff, Ariz). METHODS: From 2000 to 2007, 179 patients underwent EVAR in a tertiary institution. Clinical data were retrieved from a prospective database. All patients treated with the Excluder endoprosthesis were included. Computed tomography angiography (CTA) scans were retrospectively analyzed preoperatively, at 30 days, and at the last follow-up using dedicated tridimensional reconstruction software. For patients with complications, all remaining CTAs were also analyzed. The primary end point was clinical success. Secondary end points were freedom from reintervention, sac growth, types I and III endoleak, migration, conversion to open repair, and AAA-related death or rupture. Neck dilatation, renal function, and overall survival were also analyzed. RESULTS: Included were 144 patients (88.2% men; mean age, 71.6 years). Aneurysms were ruptured in 4.9%. American Society of Anesthesiologists classification was III/IV in 61.8%. No patients were lost during a median follow-up of 5.0 years (interquartile range, 3.1-6.4; maximum, 11.2 years). Two patients died of medical complications ≤ 30 days after EVAR. The estimated primary clinical success rates at 5 and 10 years were 63.5% and 41.1%, and secondary clinical success rates were 78.3% and 58.3%, respectively. Sac growth was observed in 37 of 142 patients (26.1%). Cox regression showed type I endoleak during follow-up (hazard ratio, 3.74; P = .008), original design model (hazard ratio, 3.85; P = .001), and preoperative neck diameter (1.27 per mm increase, P = .006) were determinants of sac growth. Secondary interventions were required in 32 patients (22.5%). The estimated 10-year rate of AAA-related death or rupture was 2.1%. Overall life expectancy after AAA repair was 6.8 years. CONCLUSIONS: EVAR using the Excluder endoprosthesis provides a safe and lasting treatment for AAA, despite the need for maintained surveillance and secondary interventions. At up to 11 years, the risk of AAA-related death or postimplantation rupture is remarkably low. The incidences of postimplantation sac growth and secondary intervention were greatly reduced after the introduction of the low-permeability design in 2004.
Resumo:
OBJECTIVE: Intensive image surveillance after endovascular aneurysm repair is generally recommended due to continued risk of complications. However, patients at lower risk may not benefit from this strategy. We evaluated the predictive value of the first postoperative computed tomography angiography (CTA) characteristics for aneurysm-related adverse events as a means of patient selection for risk-adapted surveillance. METHODS: All patients treated with the Low-Permeability Excluder Endoprosthesis (W. L. Gore & Assoc, Flagstaff, Ariz) at a tertiary institution from 2004 to 2011 were included. First postoperative CTAs were analyzed for the presence of endoleaks, endograft kinking, distance from the lowermost renal artery to the start of the endograft, and for proximal and distal sealing length using center lumen line reconstructions. The primary end point was freedom from aneurysm-related adverse events. Multivariable Cox regression was used to test postoperative CTA characteristics as independent risk factors, which were subsequently used as selection criteria for low-risk and high-risk groups. Estimates for freedom from adverse events were obtained using Kaplan-Meier survival curves. RESULTS: Included were 131 patients. The median follow-up was 4.1 years (interquartile range, 2.1-6.1). During this period, 30 patients (23%) sustained aneurysm-related adverse events. Seal length <10 mm and presence of endoleak were significant risk factors for this end point. Patients were subsequently categorized as low-risk (proximal and distal seal length ≥10 mm and no endoleak, n = 62) or high-risk (seal length <10 mm or presence of endoleak, or both; n = 69). During follow-up, four low-risk patients (3%) and 26 high-risk patients (19%) sustained events (P < .001). Four secondary interventions were required in three low-risk patients, and 31 secondary interventions in 23 high-risk patients. Sac growth was observed in two low-risk patients and in 15 high-risk patients. The 5-year estimates for freedom from aneurysm-related adverse events were 98% for the low-risk group and 52% for the high-risk group. For each diagnosis, 81.7 image examinations were necessary in the low-risk group and 8.2 in the high-risk group. CONCLUSIONS: Our results suggest that the first postoperative CTA provides important information for risk stratification after endovascular aneurysm repair when the Excluder endoprosthesis is used. In patients with adequate seal and no endoleaks, the risk of aneurysm-related adverse events was significantly reduced, resulting in a large number of unnecessary image examinations. Adjusting the imaging protocol beyond 30 days and up to 5 years, based on individual patients' risk, may result in a more efficient and rational postoperative surveillance.
Resumo:
OBJECTIVE: To determine if mid-term outcome following endovascular aneurysm repair (EVAR) with the Endurant Stent Graft (Medtronic, Santa Rosa, CA, USA) is influenced by severe proximal neck angulation. METHODS: A retrospective case-control study was performed using data from a prospective multicenter database. All measurements were obtained using dedicated reconstruction software and center-lumen line reconstruction. Patients with neck length >15 mm, infrarenal angle (β) >75°, and/or suprarenal angle (α) >60°, or neck length >10 mm with β >60°, and/or α >45° were compared with a matched control group. Primary endpoint was primary clinical success. Secondary endpoints were freedom from rupture, type 1A endoleak, stent fractures, freedom from neck-related reinterventions, and aneurysm-related adverse events. Morphological neck variation over time was also assessed. RESULTS: Forty-five patients were included in the study group and were compared with a matched control group with 65 patients. Median follow-up time was 49.5 months (range 30.5-58.4). The 4-year primary clinical success estimates were 83% and 80% for the angulated and nonangulated groups (p = .42). Proximal neck angulation did not affect primary clinical success in a multivariate model (hazard ratio 1.56, 95% confidence interval 0.55-4.41). Groups did not differ significantly in regard to freedom from rupture (p = .79), freedom from type 1A endoleak (p = .79), freedom from neck-related adverse events (p = .68), and neck-related reinterventions (p = .68). Neck angle reduction was more pronounced in patients with severe proximal neck angulation (mean Δα -15.6°, mean Δβ -30.6°) than in the control group (mean Δα -0.39°, mean Δβ -5.9°) (p < .001). CONCLUSION: Mid-term outcomes following EVAR with the Endurant Stent Graft were not influenced by severe proximal neck angulation in our population. Despite the conformability of the device, moderate aortic neck remodeling was identified in the group of patients with angulated neck anatomy on the first computed tomography scan after implantation with no important further remodeling afterwards. No device integrity failures were encountered.
Resumo:
BACKGROUND: Aneurysm shrinkage has been proposed as a marker of successful endovascular aneurysm repair (EVAR). Patients with early postoperative shrinkage may experience fewer subsequent complications, and consequently require less intensive surveillance. METHODS: Patients undergoing EVAR from 2000 to 2011 at three vascular centres (in 2 countries), who had two imaging examinations (postoperative and after 6-18 months), were included. Maximum diameter, complications and secondary interventions during follow-up were registered. Patients were categorized according to early sac dynamics. The primary endpoint was freedom from late complications. Secondary endpoints were freedom from secondary intervention, postimplant rupture and direct (type I/III) endoleaks. RESULTS: Some 597 EVARs (71.1 per cent of all EVARs) were included. No shrinkage was observed in 284 patients (47.6 per cent), moderate shrinkage (5-9 mm) in 142 (23.8 per cent) and major shrinkage (at least 10 mm) in 171 patients (28.6 per cent). Four years after the index imaging, the rate of freedom from complications was 84.3 (95 per cent confidence interval 78.7 to 89.8), 88.1 (80.6 to 95.5) and 94.4 (90.1 to 98.7) per cent respectively. No shrinkage was an independent risk factor for late complications compared with major shrinkage (hazard ratio (HR) 3.11; P < 0.001). Moderate compared with major shrinkage (HR 2.10; P = 0.022), early postoperative complications (HR 3.34; P < 0.001) and increasing abdominal aortic aneurysm baseline diameter (HR 1.02; P = 0.001) were also risk factors for late complications. Freedom from secondary interventions and direct endoleaks was greater for patients with major sac shrinkage. CONCLUSION: Early change in aneurysm sac diameter is a strong predictor of late complications after EVAR. Patients with major sac shrinkage have a very low risk of complications for up to 5 years. This parameter may be used to tailor postoperative surveillance.
Resumo:
OBJECTIVE:Endograft mural thrombus has been associated with stent graft or limb thrombosis after endovascular aneurysm repair (EVAR). This study aimed to identify clinical and morphologic determinants of endograft mural thrombus accumulation and its influence on thromboembolic events after EVAR. METHODS: A prospectively maintained database of patients treated by EVAR at a tertiary institution from 2000 to 2012 was analyzed. Patients treated for degenerative infrarenal abdominal aortic aneurysms and with available imaging for thrombus analysis were considered. All measurements were performed on three-dimensional center-lumen line computed tomography angiography (CTA) reconstructions. Patients with thrombus accumulation within the endograft's main body with a thickness >2 mm and an extension >25% of the main body's circumference were included in the study group and compared with a control group that included all remaining patients. Clinical and morphologic variables were assessed for association with significant thrombus accumulation within the endograft's main body by multivariate regression analysis. Estimates for freedom from thromboembolic events were obtained by Kaplan-Meier plots. RESULTS: Sixty-eight patients (16.4%) presented with endograft mural thrombus. Median follow-up time was 3.54 years (interquartile range, 1.99-5.47 years). In-graft mural thrombus was identified on 30-day CTA in 22 patients (32.4% of the study group), on 6-month CTA in 8 patients (11.8%), and on 1-year CTA in 17 patients (25%). Intraprosthetic thrombus progressively accumulated during the study period in 40 patients of the study group (55.8%). Overall, 17 patients (4.1%) presented with endograft or limb occlusions, 3 (4.4%) in the thrombus group and 14 (4.1%) in the control group (P = .89). Thirty-one patients (7.5%) received an aortouni-iliac (AUI) endograft. Two endograft occlusions were identified among AUI devices (6.5%; overall, 0.5%). None of these patients showed thrombotic deposits in the main body, nor were any outflow abnormalities identified on the immediately preceding CTA. Estimated freedom from thromboembolic events at 5 years was 95% in both groups (P = .97). Endograft thrombus accumulation was associated with >25% proximal aneurysm neck thrombus coverage at baseline (odds ratio [OR], 1.9; 95% confidence interval [CI], 1.1-3.3), neck length ≤ 15 mm (OR, 2.4; 95% CI, 1.3-4.2), proximal neck diameter ≥ 30 mm (OR, 2.4; 95% CI, 1.3-4.6), AUI (OR, 2.2; 95% CI, 1.8-5.5), or polyester-covered stent grafts (OR, 4.0; 95% CI, 2.2-7.3) and with main component "barrel-like" configuration (OR, 6.9; 95% CI, 1.7-28.3). CONCLUSIONS: Mural thrombus formation within the main body of the endograft is related to different endograft configurations, main body geometry, and device fabric but appears to have no association with the occurrence of thromboembolic events over time.
Resumo:
INTRODUCTION: Mitral regurgitation (MR) is the most common valvular disease and has recently become the target of a number of percutaneous approaches. The MitraClip is virtually the only device for which there is considerable experience, with more than 20,000 procedures performed worldwide. OBJECTIVE: To describe our initial experience of the percutaneous treatment of MR with the MitraClip device. METHODS: We describe the first six MitraClip cases performed in this institution (mean age 58.5 ± 13.1 years), with functional MR grade 4+ and New York Heart Association (NYHA) heart failure class III or IV (n=3), with a mean follow-up of 290 ± 145 days. RESULTS: Procedural success (MR ≤ 2+) was 100%. Total procedure time was 115.8 ± 23.7 min, with no in-hospital adverse events and discharge between the fourth and eighth day, and consistent improvement in the six-minute walk test (329.8 ± 98.42 vs. 385.33 ± 106.95 m) and in NYHA class (three patients improved by two NYHA classes). During follow-up there were two deaths, in two of the four patients who had been initially considered for heart transplantation. CONCLUSION: In patients with functional MR the MitraClip procedure is safe, with both a high implantation and immediate in-hospital success rate. A longer follow-up suggests that the clinical benefit decreases or disappears completely in patients with more advanced heart disease, namely those denied transplantation or on the heart transplant waiting list.
Resumo:
OBJECTIVE/BACKGROUND: The association between socioeconomic status (SES), presentation, and outcome after vascular surgery is largely unknown. This study aimed to determine the influence of SES on post-operative survival and severity of disease at presentation among vascular surgery patients in the Dutch setting of equal access to and provision of care. METHODS: Patients undergoing surgical treatment for peripheral artery disease (PAD), abdominal aortic aneurysm (AAA), or carotid artery stenosis between January 2003 and December 2011 were retrospectively included. The association between SES, quantified by household income, disease severity at presentation, and survival was studied using logistic and Cox regression analysis adjusted for demographics, and medical and behavioral risk factors. RESULTS: A total of 1,178 patients were included. Low income was associated with worse post-operative survival in the PAD cohort (n = 324, hazard ratio 1.05, 95% confidence interval [CI] 1.00-1.10, per 5,000 Euro decrease) and the AAA cohort (n = 440, quadratic relation, p = .01). AAA patients in the lowest income quartile were more likely to present with a ruptured aneurysm (odds ratio [OR] 2.12, 95% CI 1.08-4.17). Lowest income quartile PAD patients presented more frequently with symptoms of critical limb ischemia, although no significant association could be established (OR 2.02, 95% CI 0.96-4.26). CONCLUSIONS: The increased health hazards observed in this study are caused by patient related factors rather than differences in medical care, considering the equality of care provided by the study setting. Although the exact mechanism driving the association between SES and worse outcome remains elusive, consideration of SES as a risk factor in pre-operative decision making and focus on treatment of known SES related behavioral and psychosocial risk factors may improve the outcome of patients with vascular disease.
Resumo:
Flexor hallucis longus (FHL) transfer is a well-established treatment option in failed Achilles tendon (AT) repair and has been routinely performed as an open procedure. We detail the surgical steps needed to perform an arthroscopic transfer of the FHL for a chronic AT rupture. The FHL tendon is harvested as it enters in its tunnel beneath the sustentaculum tali; a tunnel is then drilled in the calcaneus as near to the AT footprint as possible. By use of a suture-passing device, the free end of the FHL is advanced to the plantar aspect of the foot. After adequate tension is applied to the construct, the tendon is fixed in place with an interference screw in an inside-out fashion. This minimally invasive approach is a safe and valid alternative to classic open procedures with the obvious advantages of preserving the soft-tissue envelope and using a biologically intact tendon.
Resumo:
Pseudo-Kaposi sarcoma is a benign reactive vascular proliferation mainly involving the lower legs, which can be related to acquired chronic venous insufficiency or congenital arteriovenous malformations. In its most common presentation, acroangiodermatitis is seen in patients with chronic venous insufficiency of the lower limbs as an exaggeration of the stasis dermatitis. However, rare reports of acroangiodermatitis include descriptions in amputees (especially in those with poorly fitting suction-type devices), in patients undergoing hemodialysis (with lesions developing distally to arteriovenous shunts) and in patients with paralyzed legs. We report on a 28 year-old-male who presented pseudo-Kaposi's sarcoma in an amputation stump because of suction-socket lower limb prosthesis.